Quantitative high-throughput analysis of drugs in biological matrices by mass spectrometry

被引:215
作者
Hopfgartner, G [1 ]
Bourgogne, E [1 ]
机构
[1] Univ Geneva, Sch Pharm, Lab Pharmaceut Analyt Chem, CH-1211 Geneva 4, Switzerland
关键词
high-throughput analysis; biological fluids; quantitation; LC-MS;
D O I
10.1002/mas.10050
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
To support pharmacokinetic and drug metabolism studies, LC-MS/MS plays more and more an essential role for the quantitation of drugs and their metabolites in biological matrices. With the new challenges encountered in drug discovery and drug development, new strategies are put in place to achieve high-throughput analysis, using serial and parallel approaches. To speed-up method development and validation, generic approaches with the direct injection of biological fluids is highly desirable. Column-switching, using various packing materials for the extraction columns, is widely applied. Improvement of mass spectrometers performance, and in particular triple quadrupoles, also strongly influences sample preparation strategies, which remain a key element in the bioanalytical process. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:195 / 214
页数:20
相关论文
共 128 条
[31]  
Gobry V, 2002, PROTEOMICS, V2, P405, DOI 10.1002/1615-9861(200204)2:4<405::AID-PROT405>3.0.CO
[32]  
2-Y
[33]   Generic serial and parallel on-line direct-injection using turbulent flow liquid chromatography/tandem mass spectrometry [J].
Grant, RP ;
Cameron, C ;
Mackenzie-McMurter, S .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (18) :1785-1792
[34]   A new linear ion trap mass spectrometer [J].
Hager, JW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (06) :512-526
[35]   A preliminary study on the feasibility of an automated blood-sampling system in conjunction with liquid chromatography/mass spectrometry [J].
He, H ;
Kramp, R ;
Ramos, L ;
Bakhtiar, R .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (18) :1768-1772
[36]   Fast liquid chromatographic-mass spectrometric determination of pharmaceutical compounds [J].
Heinig, K ;
Henion, J .
JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (02) :445-458
[37]   Application of column-switching liquid chromatography-tandem mass spectrometry for the determination of pharmaceutical compounds in tissue samples [J].
Heinig, K ;
Bucheli, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 769 (01) :9-26
[38]   Generic method for on-line extraction of drug substances in the presence of biological matrices using turbulent flow chromatography [J].
Herman, JL .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (05) :421-426
[39]  
Hiller DL, 2000, RAPID COMMUN MASS SP, V14, P2034, DOI 10.1002/1097-0231(20001115)14:21<2034::AID-RCM124>3.0.CO
[40]  
2-6