Speckle-Based X-Ray Dark-Field Tomography of an Attenuating Object

被引:3
作者
Alloo, S. J. [1 ]
Paganin, D. M. [2 ]
Morgan, K. S. [2 ]
Kitchen, M. J. [2 ]
Stevenson, A. W. [3 ]
Mayo, S. C. [4 ]
Li, H. T. [5 ]
Kennedy, B. M. [6 ]
Maksimenko, A. [3 ]
Bowden, J. [4 ]
Pavlov, K. M. [1 ,2 ,7 ]
机构
[1] Univ Canterbury, Sch Phys & Chem Sci, Christchurch 8041, New Zealand
[2] Monash Univ, Sch Phys & Astron, Clayton, Vic 3800, Australia
[3] Australian Synchrotron, ANSTO, Clayton, Vic 3168, Australia
[4] Commonwealth Sci & Ind Res Org, Clayton, Vic 3168, Australia
[5] Univ Canterbury, Sch Math, Christchurch 8041, New Zealand
[6] Univ Canterbury, Sch Earth & Environm, Christchurch 8041, New Zealand
[7] Univ New England, Armidale, NSW 2351, Australia
来源
DEVELOPMENTS IN X-RAY TOMOGRAPHY XIII | 2021年 / 11840卷
基金
澳大利亚研究理事会;
关键词
Speckle-Based X-Ray Imaging; Phase-Contrast Imaging; Dark-Field Imaging; Computed Tomography; PHASE-CONTRAST; COMPUTED-TOMOGRAPHY; IMAGE; RETRIEVAL;
D O I
10.1117/12.2597722
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Spatial resolution in standard phase-contrast X-ray imaging is limited by the finite number and size of detector pixels. This limits the size of features that can be seen directly in projection images or tomographic reconstructions. Dark-field imaging allows information regarding such features to be obtained, as the reconstructed image is a measure of the position-dependent small-angle X-ray scattering of incident rays from the unresolved microstructure. In this paper we utilize an intrinsic speckle-tracking-based X-ray imaging technique to obtain the effective dark-field signal from a wood sample. This effective dark-field signal is extracted using a Fokker-Planck type formalism, which models the deformations of illuminating reference-beam speckles due to both coherent and diffusive scatter from the sample. We here assume that (a) small-angle scattering fans at the exit surface of the sample are rotationally symmetric, and (b) the object has both attenuating and refractive properties. The associated inverse problem, of extracting the effective dark-field signal, is numerically stabilised using a \weighted determinants" approach. Effective dark-field projection images are presented, as well as the dark-field tomographic reconstructions obtained using Fokker-Planck implicit speckle-tracking.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Recent advances in X-ray grating-based dark-field imaging
    Wang, Zhili
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2024, 181
  • [32] Grating-based x-ray dark-field CT for lung cancer diagnosis in mice
    Guo, Peiyuan
    Zhang, Li
    Lu, Jincheng
    Zhang, Huitao
    Zhu, Xiaohua
    Wu, Chengpeng
    Zhan, Xiangwen
    Yin, Hongxia
    Wang, Zhenchang
    Xu, Yan
    Wang, Zhentian
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [33] Dark-field X-ray imaging of unsaturated water transport in porous materials
    Yang, F.
    Prade, F.
    Griffa, M.
    Jerjen, I.
    Di Bella, C.
    Herzen, J.
    Sarapata, A.
    Pfeiffer, F.
    Lura, P.
    APPLIED PHYSICS LETTERS, 2014, 105 (15)
  • [34] X-Ray Dark-field Imaging to Depict Acute Lung Inflammation in Mice
    Hellbach, Katharina
    Meinel, Felix G.
    Conlon, Thomas M.
    Willer, Konstantin
    Yaroshenko, Andre
    Velroyen, Astrid
    Braunagel, Margarita
    Auweter, Sigrid
    Reiser, Maximilian F.
    Eickelberg, Oliver
    Pfeiffer, Franz
    Yildirim, Ali Oe.
    SCIENTIFIC REPORTS, 2018, 8
  • [35] Whole-body x-ray dark-field radiography of a human cadaver
    Andrejewski, Jana
    De Marco, Fabio
    Willer, Konstantin
    Noichl, Wolfgang
    Gustschin, Alex
    Koehler, Thomas
    Meyer, Pascal
    Kriner, Fabian
    Fischer, Florian
    Braun, Christian
    Fingerle, Alexander A.
    Herzen, Julia
    Pfeiffer, Franz
    Pfeiffer, Daniela
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2021, 5 (01)
  • [36] X-Ray Dark-Field Signal Reduction Due to Hardening of the Visibility Spectrum
    De Marco, Fabio
    Andrejewski, Jana
    Urban, Theresa
    Willer, Konstantin
    Gromann, Lukas
    Koehler, Thomas
    Maack, Hanns-Ingo
    Herzen, Julia
    Pfeiffer, Franz
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2024, 43 (04) : 1422 - 1433
  • [37] Detection of individual sub-pixel features in edge-illumination x-ray phase contrast imaging by means of the dark-field channel
    Matsunaga, Norihito
    Yano, Kazuhiro
    Endrizzi, Marco
    Olivo, Alessandro
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2020, 53 (09)
  • [38] Directional dark-field implicit x-ray speckle tracking using an anisotropic-diffusion Fokker-Planck equation
    Pavlov, Konstantin M.
    Paganin, David M.
    Morgan, Kaye S.
    Li, Heyang
    Berujon, Sebastien
    Quenot, Laurene
    Brun, Emmanuel
    PHYSICAL REVIEW A, 2021, 104 (05)
  • [39] X-ray phase contrast tomography by tracking near field speckle
    Wang, Hongchang
    Berujon, Sebastien
    Herzen, Julia
    Atwood, Robert
    Laundy, David
    Hipp, Alexander
    Sawhney, Kawal
    SCIENTIFIC REPORTS, 2015, 5
  • [40] X-ray Dark-Field Imaging (XDFI)-a Promising Tool for 3D Virtual Histopathology
    Shimao, Daisuke
    Sunaguchi, Naoki
    Yuasa, Tetsuya
    Ando, Masami
    Mori, Kensaku
    Gupta, Rajiv
    Ichihara, Shu
    MOLECULAR IMAGING AND BIOLOGY, 2021, 23 (04) : 481 - 494