Speckle-Based X-Ray Dark-Field Tomography of an Attenuating Object

被引:3
|
作者
Alloo, S. J. [1 ]
Paganin, D. M. [2 ]
Morgan, K. S. [2 ]
Kitchen, M. J. [2 ]
Stevenson, A. W. [3 ]
Mayo, S. C. [4 ]
Li, H. T. [5 ]
Kennedy, B. M. [6 ]
Maksimenko, A. [3 ]
Bowden, J. [4 ]
Pavlov, K. M. [1 ,2 ,7 ]
机构
[1] Univ Canterbury, Sch Phys & Chem Sci, Christchurch 8041, New Zealand
[2] Monash Univ, Sch Phys & Astron, Clayton, Vic 3800, Australia
[3] Australian Synchrotron, ANSTO, Clayton, Vic 3168, Australia
[4] Commonwealth Sci & Ind Res Org, Clayton, Vic 3168, Australia
[5] Univ Canterbury, Sch Math, Christchurch 8041, New Zealand
[6] Univ Canterbury, Sch Earth & Environm, Christchurch 8041, New Zealand
[7] Univ New England, Armidale, NSW 2351, Australia
来源
DEVELOPMENTS IN X-RAY TOMOGRAPHY XIII | 2021年 / 11840卷
基金
澳大利亚研究理事会;
关键词
Speckle-Based X-Ray Imaging; Phase-Contrast Imaging; Dark-Field Imaging; Computed Tomography; PHASE-CONTRAST; COMPUTED-TOMOGRAPHY; IMAGE; RETRIEVAL;
D O I
10.1117/12.2597722
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Spatial resolution in standard phase-contrast X-ray imaging is limited by the finite number and size of detector pixels. This limits the size of features that can be seen directly in projection images or tomographic reconstructions. Dark-field imaging allows information regarding such features to be obtained, as the reconstructed image is a measure of the position-dependent small-angle X-ray scattering of incident rays from the unresolved microstructure. In this paper we utilize an intrinsic speckle-tracking-based X-ray imaging technique to obtain the effective dark-field signal from a wood sample. This effective dark-field signal is extracted using a Fokker-Planck type formalism, which models the deformations of illuminating reference-beam speckles due to both coherent and diffusive scatter from the sample. We here assume that (a) small-angle scattering fans at the exit surface of the sample are rotationally symmetric, and (b) the object has both attenuating and refractive properties. The associated inverse problem, of extracting the effective dark-field signal, is numerically stabilised using a \weighted determinants" approach. Effective dark-field projection images are presented, as well as the dark-field tomographic reconstructions obtained using Fokker-Planck implicit speckle-tracking.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] X-ray dark-field computed tomography using a grating interferometer setup
    Bevins, Nicholas
    Zambelli, Joseph
    Qi, Zhihua
    Chen, Guang-Hong
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [22] X-ray dark-field imaging with a single absorption grating
    Yang, Jun
    Zong, Fangke
    Lei, Yaohu
    Huang, Jianheng
    Liu, Jinyuan
    Guo, Jinchuan
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2019, 52 (19)
  • [23] X-ray dark-field via spectral propagation-based imaging
    Ahlers, Jannis N.
    Pavlov, Konstantin M.
    Kitchen, Marcus J.
    Morgan, Kaye S.
    OPTICA, 2024, 11 (08): : 1182 - 1191
  • [24] Grating-based X-ray dark-field computed tomography for the characterization of friction stir welds: A feasibility study
    Schaff, Florian
    Bachmann, Andreas
    Zens, Amanda
    Zaeh, Michael F.
    Pfeiffer, Franz
    Herzen, Julia
    MATERIALS CHARACTERIZATION, 2017, 129 : 143 - 148
  • [25] Tomography of dark-field scatter including single-exposure Moire fringe analysis with X-ray biprism interferometry-A simulation study
    Tao, Weijie
    Sung, Yongjin
    Kim, Sally Ji Who
    Huang, Qiu
    Gullberg, Grant T.
    Seo, Youngho
    Fuller, Michael
    MEDICAL PHYSICS, 2021, 48 (10) : 6293 - 6311
  • [26] Advanced Phase-Retrieval for Stepping-Free X-Ray Dark-Field Computed Tomography
    Haeusele, Jakob
    Schmid, Clemens
    Viermetz, Manuel
    Gustschin, Nikolai
    Lasser, Tobias
    Koehler, Thomas
    Pfeiffer, Franz
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2023, 42 (10) : 2876 - 2885
  • [27] Refraction-enhanced tomosynthesis of a finger joint by X-ray dark-field imaging
    Shimao, Daisuke
    Kunisada, Toshiyuki
    Sugiyama, Hiroshi
    Ando, Masami
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2007, 46 (25-28): : L608 - L610
  • [28] Tissue Visualization Using X-Ray Dark-Field Imaging towards Pathological Goal
    Ando, Masami
    Chikaura, Yoshinori
    Endo, Tokiko
    Gupta, Rajiv
    Huo, Qingkai
    Hyodo, Kazuyuki
    Ichihara, Shu
    Mori, Kensaku
    Nakao, Yuki
    Ohura, Norihiko
    Sunaguchi, Naoki
    Sugiyama, Hiroshi
    Suzuki, Yoshifumi
    Wu, Yanlin
    Yuasa, Tetsuya
    Zhang Xiaowei
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [29] Hard X-ray dark-field imaging with incoherent sample illumination
    Endrizzi, Marco
    Diemoz, Paul C.
    Millard, Thomas P.
    Jones, J. Louise
    Speller, Robert D.
    Robinson, Ian K.
    Olivo, Alessandro
    APPLIED PHYSICS LETTERS, 2014, 104 (02)
  • [30] Directional x-ray dark-field imaging of strongly ordered systems
    Jensen, Torben Haugaard
    Bech, Martin
    Zanette, Irene
    Weitkamp, Timm
    David, Christian
    Deyhle, Hans
    Rutishauser, Simon
    Reznikova, Elena
    Mohr, Juergen
    Feidenhans'l, Robert
    Pfeiffer, Franz
    PHYSICAL REVIEW B, 2010, 82 (21):