Speckle-Based X-Ray Dark-Field Tomography of an Attenuating Object

被引:3
|
作者
Alloo, S. J. [1 ]
Paganin, D. M. [2 ]
Morgan, K. S. [2 ]
Kitchen, M. J. [2 ]
Stevenson, A. W. [3 ]
Mayo, S. C. [4 ]
Li, H. T. [5 ]
Kennedy, B. M. [6 ]
Maksimenko, A. [3 ]
Bowden, J. [4 ]
Pavlov, K. M. [1 ,2 ,7 ]
机构
[1] Univ Canterbury, Sch Phys & Chem Sci, Christchurch 8041, New Zealand
[2] Monash Univ, Sch Phys & Astron, Clayton, Vic 3800, Australia
[3] Australian Synchrotron, ANSTO, Clayton, Vic 3168, Australia
[4] Commonwealth Sci & Ind Res Org, Clayton, Vic 3168, Australia
[5] Univ Canterbury, Sch Math, Christchurch 8041, New Zealand
[6] Univ Canterbury, Sch Earth & Environm, Christchurch 8041, New Zealand
[7] Univ New England, Armidale, NSW 2351, Australia
来源
DEVELOPMENTS IN X-RAY TOMOGRAPHY XIII | 2021年 / 11840卷
基金
澳大利亚研究理事会;
关键词
Speckle-Based X-Ray Imaging; Phase-Contrast Imaging; Dark-Field Imaging; Computed Tomography; PHASE-CONTRAST; COMPUTED-TOMOGRAPHY; IMAGE; RETRIEVAL;
D O I
10.1117/12.2597722
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Spatial resolution in standard phase-contrast X-ray imaging is limited by the finite number and size of detector pixels. This limits the size of features that can be seen directly in projection images or tomographic reconstructions. Dark-field imaging allows information regarding such features to be obtained, as the reconstructed image is a measure of the position-dependent small-angle X-ray scattering of incident rays from the unresolved microstructure. In this paper we utilize an intrinsic speckle-tracking-based X-ray imaging technique to obtain the effective dark-field signal from a wood sample. This effective dark-field signal is extracted using a Fokker-Planck type formalism, which models the deformations of illuminating reference-beam speckles due to both coherent and diffusive scatter from the sample. We here assume that (a) small-angle scattering fans at the exit surface of the sample are rotationally symmetric, and (b) the object has both attenuating and refractive properties. The associated inverse problem, of extracting the effective dark-field signal, is numerically stabilised using a \weighted determinants" approach. Effective dark-field projection images are presented, as well as the dark-field tomographic reconstructions obtained using Fokker-Planck implicit speckle-tracking.
引用
收藏
页数:13
相关论文
共 50 条
  • [11] X-ray dark-field imaging modeling
    Cong, W.
    Pfeiffer, F.
    Bech, M.
    Wang, G.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2012, 29 (06) : 908 - 912
  • [12] Quantitative X-ray dark-field and phase tomography using single directional speckle scanning technique
    Wang, Hongchang
    Kashyap, Yogesh
    Sawhney, Kawal
    APPLIED PHYSICS LETTERS, 2016, 108 (12)
  • [13] Complementary use of x-ray dark-field and attenuation computed tomography in quantifying pulmonary fibrosis in a mouse model
    Nelson, Brandon J.
    Leng, Shuai
    Koenig, Thomas
    McCollough, Cynthia H.
    MEDICAL IMAGING 2022: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2022, 12036
  • [14] Hybrid dark-field and attenuation contrast retrieval for laboratory-based X-ray tomography
    Doherty, Adam
    Buchanan, Ian
    Roche I Morgo, Oriol
    Astolfo, Alberto
    Savvidis, Savvas
    Gerli, Mattia F. M.
    Citro, Antonio
    Olivo, Alessandro
    Endrizzi, Marco
    OPTICA, 2024, 11 (12): : 1603 - 1613
  • [15] X-ray phase and dark-field computed tomography without optical elements
    Eatham, T. homas a. l
    Aganin, D. avid m. p
    Organ, K. aye s. m
    OPTICS EXPRESS, 2024, 32 (03): : 4588 - 4602
  • [16] Two-shot X-ray dark-field imaging
    Marschner, M.
    Birnbacher, L.
    Mechlem, K.
    Noichl, W.
    Fehringer, A.
    Willner, M.
    Scherer, K.
    Herzen, J.
    Noel, P. B.
    Pfeiffer, F.
    OPTICS EXPRESS, 2016, 24 (23): : 27032 - 27045
  • [17] Effect of particle-size selectivity on quantitative X-ray dark-field computed tomography using a grating interferometer
    Bao, Yuan
    Shao, Qigang
    Hu, Renfang
    Wang, Shengxiang
    Gao, Kun
    Wang, Yan
    Tian, Yangchao
    Zhu, Peiping
    RADIATION PHYSICS AND CHEMISTRY, 2017, 137 : 260 - 263
  • [18] A first investigation of accuracy, precision and sensitivity of phase-based x-ray dark-field imaging
    Astolfo, Alberto
    Endrizzi, Marco
    Kallon, Gibril
    Millard, Thomas P.
    Vittoria, Fabio A.
    Olivo, Alessandro
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2016, 49 (48)
  • [19] Grating-based X-ray Dark-field Computed Tomography of Living Mice
    Velroyen, A.
    Yaroshenko, A.
    Hahn, D.
    Fehringer, A.
    Tapfer, A.
    Mueller, M.
    Noel, P. B.
    Pauwels, B.
    Sasov, A.
    Yildirim, A. Oe.
    Eickelberg, O.
    Hellbach, K.
    Auweter, S. D.
    Meinel, F. G.
    Reiser, M. F.
    Bech, M.
    Pfeiffer, F.
    EBIOMEDICINE, 2015, 2 (10): : 1500 - 1506
  • [20] PRECLINICAL X-RAY DARK-FIELD RADIOGRAPHY FOR PULMONARY EMPHYSEMA EVALUATION
    Yaroshenko, A.
    Meinel, F. G.
    Bech, M.
    Tapfer, A.
    Velroyen, A.
    Schleede, S.
    Mueller, M.
    Auweter, S.
    Bohla, A.
    Yildirim, A. Oe
    Nikolaou, K.
    Bamberg, F.
    Eickelberg, O.
    Reiser, M.
    Pfeiffer, F.
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 370 - 373