Precision of bone density and micro-architectural properties at the distal radius and tibia in children: an HR-pQCT study

被引:12
作者
Kawalilak, C. E. [1 ]
Bunyamin, A. T. [1 ]
Bjorkman, K. M. [2 ]
Johnston, J. D. [1 ]
Kontulainen, S. A. [2 ]
机构
[1] Univ Saskatchewan, Dept Mech Engn, Coll Engn, 57 Campus Dr, Saskatoon, SK S7N 5A9, Canada
[2] Univ Saskatchewan, Coll Kinesiol, 87 Campus Dr, Saskatoon, SK S7N 5B2, Canada
关键词
In vivo; Least significant change; Pediatric; Reproducibility; Short-termrepeatability; QUANTITATIVE COMPUTED-TOMOGRAPHY; ADOLESCENT IDIOPATHIC SCOLIOSIS; YOUNG-ADULTS; POSTMENOPAUSAL WOMEN; OFFICIAL POSITIONS; PHYSICAL-ACTIVITY; NORMATIVE DATA; HEALTHY BOYS; STRENGTH; MICROARCHITECTURE;
D O I
10.1007/s00198-017-4185-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Precision errors need to be known when monitoring bone micro-architecture in children with HR-pQCT. Precision errors for trabecular bone micro-architecture ranged from 1 to 8% when using the standard evaluation at the radius and tibia. Precision errors for cortical bone micro-architecture ranged from 1 to 11% when using the advanced cortical evaluation. Introduction Our objective was to define HR-pQCT precision errors (CV%(RMS)) and least significant changes (LSCs) at the distal radius and tibia in children using the standard evaluation and the advanced cortical evaluation. Methods We scanned the distal radius (7% of ulnar length) and tibia (8% of tibia length) of 32 children (age range 8-13; mean age 11.3; SD 1.6 years) twice (1 week apart) using HR-pQCT (XtremeCT1). We calculated root-mean-squared coefficients of variation (CV%(RMS)) to define precision errors and LSC to identify differences required to detect change. Results Precision errors ranged between 1-8 and 1-5% for trabecular bone outcomes (obtained with standard evaluation) and between 1.5-11 and 0.5-6% for cortical bone outcomes (obtained with advanced cortical evaluation) at the distal radius and tibia, respectively. Related LSCs ranged between 3-21 and 3-14% for trabecular bone outcomes and between 4-30 and 2-16% for cortical bone outcomes at the distal radius and tibia, respectively. Conclusion HR-pQCT precision errors were between 1 and 8% (LSC 3-21%) for trabecular bone outcomes and 1 and 11% (LSC 2-30%) for cortical bone outcomes at the radius and tibia in children. Cortical bone outcomes obtained using the advanced cortical evaluation appeared to have lower precision errors than cortical outcomes derived using the standard evaluation. These findings, combined with better-defined cortical bone contours with advanced cortical evaluation, indicate that metrics from advanced cortical evaluation should be utilized when monitoring cortical bone properties in children.
引用
收藏
页码:3189 / 3197
页数:9
相关论文
共 44 条
  • [1] Bone Microarchitecture Is Impaired in Adolescent Amenorrheic Athletes Compared with Eumenorrheic Athletes and Nonathletic Controls
    Ackerman, Kathryn E.
    Nazem, Taraneh
    Chapko, Dorota
    Russell, Melissa
    Mendes, Nara
    Taylor, Alexander P.
    Bouxsein, Mary L.
    Misra, Madhusmita
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2011, 96 (10) : 3123 - 3133
  • [2] Bone assessment in children with chronic kidney disease: data from two new bone imaging techniques in a single-center pilot study
    Bacchetta, Justine
    Boutroy, Stephanie
    Vilayphiou, Nicolas
    Ranchin, Bruno
    Fouque-Aubert, Anne
    Basmaison, Odile
    Cochat, Pierre
    [J]. PEDIATRIC NEPHROLOGY, 2011, 26 (04) : 587 - 595
  • [3] Baim S, 2008, J CLIN DENSITOM, V11, P6, DOI 10.1016/j.jocd.2007.12.002
  • [4] The comparability of HR-pQCT bone measurements is improved by scanning anatomically standardized regions
    Bonaretti, S.
    Majumdar, S.
    Lang, T. F.
    Khosla, S.
    Burghardt, A. J.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2017, 28 (07) : 2115 - 2128
  • [5] Importance of precision in bone density measurements
    Bonnick, SL
    Johnston, CC
    Kleerekoper, M
    Lindsay, R
    Miller, P
    Sherwood, L
    Siris, E
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2001, 4 (02) : 105 - 110
  • [6] Reproducibility of direct quantitative measures of cortical bone microarchitecture of the distal radius and tibia by HR-pQCT
    Burghardt, Andrew J.
    Buie, Helen R.
    Laib, Andres
    Majumdar, Sharmila
    Boyd, Steven K.
    [J]. BONE, 2010, 47 (03) : 519 - 528
  • [7] Age- and Gender-Related Differences in the Geometric Properties and Biomechanical Significance of Intracortical Porosity in the Distal Radius and Tibia
    Burghardt, Andrew J.
    Kazakia, Galateia J.
    Ramachandran, Sweta
    Link, Thomas M.
    Majumdar, Sharmila
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (05) : 983 - 993
  • [8] High-resolution peripheral QCT imaging of bone micro-structure in adolescents
    Burrows, M.
    Liu, D.
    McKay, H.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2010, 21 (03) : 515 - 520
  • [9] Assessing Bone Microstructure at the Distal Radius in Children and Adolescents Using HR-pQCT: A Methodological Pilot Study
    Burrows, Melonie
    Liu, Danmei
    Perdios, Angeliki
    Moore, Sarah
    Mulpuri, Kishore
    McKay, Heather
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2010, 13 (04) : 451 - 455
  • [10] Bone Microstructure at the Distal Tibia Provides a Strength Advantage to Males in Late Puberty: An HR-pQCT Study
    Burrows, Melonie
    Liu, Danmei
    Moore, Sarah
    McKay, Heather
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (06) : 1423 - 1432