Analysis of Fentanyl in Urine by DLLME-GC-MS

被引:30
作者
Gardner, Michael A. [1 ]
Sampsel, Sheena [2 ]
Jenkins, Werner W. [1 ,3 ]
Owens, Janel E. [1 ]
机构
[1] Univ Colorado, Dept Chem & Biochem, Colorado Springs, CO 80918 USA
[2] Univ Colorado, Beth El Coll Nursing & Hlth Sci, Colorado Springs, CO 80918 USA
[3] El Paso Cty Coroners Off, Colorado Springs, CO USA
关键词
SOLID-PHASE MICROEXTRACTION; LIQUID; CHROMATOGRAPHY;
D O I
10.1093/jat/bku136
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fentanyl is a synthetic narcotic anesthetic similar to 80-100 times more potent than morphine. Owing to the potential for its abuse, the drug may be included in a forensic toxicology work-up, which requires fast, precise and accurate measurements. Here, the stability of fentanyl was assessed when stored at three different temperatures (-20, 4 and 25 degrees C) in synthetic urine. Stability at those three temperatures was demonstrated over 12 weeks upon analysis by gas chromatography-mass spectrometry with a deuterated internal standard (fentanyl-D-5) utilizing three different extraction techniques: liquid-liquid extraction (LLE), solid-phase extraction and dispersed liquid-liquid micro-extraction (DLLME). The DLLME method was then optimized before use in the analysis of fentanyl in urine samples obtained from autopsy cases at the El Paso County Coroner's Office. Accuracy of the DLLME method was assessed by completing spike and recovery studies at three different fortification levels (10, 100 and 250 ng/mL) with excellent recovery (89.9-102.6%). The excellent comparability between DLLME and LLE is demonstrated (Bland-Altman difference plot with a mean difference of 4.9 ng/mL) and the use of this methodology in the analysis of forensically relevant samples is discussed.
引用
收藏
页码:118 / 125
页数:8
相关论文
共 27 条
[1]   Fentanyl-associated Fatalities Among Illicit Drug Users in Wayne County, Michigan (July 2005-May 2006) [J].
Algren D.A. ;
Monteilh C.P. ;
Punja M. ;
Schier J.G. ;
Belson M. ;
Hepler B.R. ;
Schmidt C.J. ;
Miller C.E. ;
Patel M. ;
Paulozzi L.J. ;
Straetemans M. ;
Rubin C. .
Journal of Medical Toxicology, 2013, 9 (1) :106-115
[2]   Human Tissue Ownership and Use in Research: What Laboratorians and Researchers Should Know [J].
Allen, Monica J. ;
Powers, Michelle L. E. ;
Gronowski, K. Scott ;
Gronowski, Ann M. .
CLINICAL CHEMISTRY, 2010, 56 (11) :1675-1682
[3]  
[Anonymous], 2012, J FORENSIC RES, DOI DOI 10.4172/2157-7145.1000157
[4]  
[Anonymous], 2005, NONPHARMACEUTICAL FE, P793
[5]   Liquid phase microextraction applications in food analysis [J].
Asensio-Ramos, Maria ;
Ravelo-Perez, Lidia M. ;
Angel Gonzalez-Curbelo, Miguel ;
Hernandez-Borges, Javier .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (42) :7415-7437
[6]   Role of microextraction sampling procedures in forensic toxicology [J].
Barroso, Mario ;
Moreno, Ivo ;
da Fonseca, Beatriz ;
Queiroz, Joao Antonio ;
Gallardo, Eugenia .
BIOANALYSIS, 2012, 4 (14) :1805-1826
[7]   Quantitative determination of 43 common drugs and drugs of abuse in human serum by HPLC-MS/MS [J].
Bassan, David M. ;
Erdmann, Freidoon ;
Kruell, Ralf .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (01) :43-50
[8]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[9]   Introduction of solid-phase microextraction as a high-throughput sample preparation tool in laboratory analysis of prohibited substances [J].
Boyaci, Ezel ;
Gorynski, Krzysztof ;
Rodriguez-Lafuente, Angel ;
Bojko, Barbara ;
Pawliszyn, Janusz .
ANALYTICA CHIMICA ACTA, 2014, 809 :69-81
[10]   Simultaneous determination of fentanyl and midazolam in plasma using direct solid-phase microextraction before gas chromatography-mass spectrometry analysis [J].
Dufresne, C ;
Favetta, P ;
Gonin, R ;
Bureau, J ;
Guitton, J .
ANALYTICAL LETTERS, 2002, 35 (09) :1575-1590