Enzymatic flow-injection determination of phytase-hydrolysable phosphorus (PHP) in natural waters using immobilized 3-phytase

被引:3
作者
Omaka, Omaka N. [1 ,2 ]
Keith-Roach, Miranda [1 ]
McKelvis, Ian D. [3 ]
Worsfold, Paul J. [1 ]
机构
[1] Univ Plymouth, Sch Earth Ocean & Environm Sci, Plymouth PL4 8AA, Devon, England
[2] Ebonyi State Univ, Dept Chem, Abakaliki, Ebonyi State, Nigeria
[3] Monash Univ, Sch Chem, Water Studies Ctr, Clayton, Vic 3800, Australia
关键词
immobilized phytase; controlled-pore glass; phytase hydrolysable phosphorus; spectrophotometry; phytic acid; flow injection;
D O I
10.1080/03067310701451061
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Phytic acid, also known as myo-inositol hexakisphosphate, is a naturally occurring, non-toxic phosphoric ester that is abundant in seeds and plants as well as aquatic sediments and in soils. It is hydrolysed to a less phosphorylated form by phytases, which are naturally occurring phosphohydrolase enzymes. Because of their non-specificity, phytases also hydrolyse other phosphoester compounds, liberating bioavailable orthophosphate. A flow-injection (FI) method for the determination of phytase hydrolysable phosphorus (PHP) using immobilized phytase is proposed. The method is suitable for the determination of PHP in natural waters, a parameter that may provide a measure of potential long-term bioavailability of organic phosphorus in aquatic systems. Sample volume, temperature, and buffer composition for the immobilized phytase hydrolysis were all optimized. The effects of the potentially interfering ions Al3+, Fe2+, Fe3+, Mn2+, Cu2+, Pb2+, NO2-, NO3-, I-, SO42, AsO43-, and EDTA and urea were also investigated. The method has a limit of detection of 5 mu g P L-1, and the optimized RSD was typically < 4% (n = 4). The spike recoveries of phytic acid as P were >= 95%. The optimized method was applied to the determination of phytase hydrolysable phosphorus in the Tamar Estuary, and the results obtained (14-25 mu g P L-1) show that this fraction constitutes a significant portion of the total dissolved P pool in the estuary.
引用
收藏
页码:91 / 101
页数:11
相关论文
共 50 条
  • [41] APPLICATION OF 3 CHROMOGENIC REAGENTS TO THE DETERMINATION OF PALLADIUM USING A LABORATORY-MADE OPTICAL FIBER DETECTOR FOR FLOW-INJECTION ANALYSIS
    XU, YJ
    CHEN, XG
    LIU, MC
    HU, Z
    [J]. ANALYTICA CHIMICA ACTA, 1992, 262 (01) : 97 - 102
  • [42] Flow injection analysis method for determination of total dissolved nitrogen in natural waters using on-line ultraviolet digestion and vanadium chloride reduction
    Lin, Kunning
    Xu, Jin
    Guo, Huige
    Huo, Yunlong
    Zhang, Yuanbiao
    [J]. MICROCHEMICAL JOURNAL, 2021, 164
  • [43] Spectrophotometric determination of zinc and copper in a multi-syringe flow injection analysis system using a liquid waveguide capillary cell: Application to natural waters
    Pascoa, Ricardo N. M. J.
    Toth, Ildiko V.
    Rangel, Antonio O. S. S.
    [J]. TALANTA, 2011, 84 (05) : 1267 - 1272
  • [44] Determination of nano-molar levels of formaldehyde in drinking water using flow-injection system with immobilized formaldehyde dehydrogenase after off-line solid-phase extraction
    Kiba, N
    Sun, L
    Yokose, S
    Kazue, MT
    Suzuki, TT
    [J]. ANALYTICA CHIMICA ACTA, 1999, 378 (1-3) : 169 - 175
  • [45] A very sensitive flow-injection spectrophotometric determination method for iron (II) and total iron using 2′, 3, 4′, 5, 7-pentahydroxyflavone
    Adem Asan
    Rukiye Aydin
    Deniz Karsli Semiz
    Vildan Erci
    Ibrahim Isildak
    [J]. Environmental Monitoring and Assessment, 2013, 185 : 2115 - 2121
  • [46] A very sensitive flow-injection spectrophotometric determination method for iron (II) and total iron using 2′, 3, 4′, 5, 7-pentahydroxyflavone
    Asan, Adem
    Aydin, Rukiye
    Semiz, Deniz Karsli
    Erci, Vildan
    Isildak, Ibrahim
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2013, 185 (03) : 2115 - 2121
  • [47] AMPEROMETRIC FLOW-INJECTION DETERMINATION OF GLUCOSE, URATE AND CHOLESTEROL IN BLOOD-SERUM BY USING SOME IMMOBILIZED ENZYME REACTORS AND A POLY(1,2-DIAMINOBENZENE)-COATED PLATINUM-ELECTRODE
    YAO, T
    SATOMURA, M
    NAKAHARA, T
    [J]. ANALYTICA CHIMICA ACTA, 1994, 296 (03) : 271 - 276
  • [48] Flow-injection chemiluminescence determination of cobalt using a cobalt(II) (1,10-phenanthroline)3 complex-catalyzed lucigenin-periodate reaction
    Du, JX
    Lu, JR
    Zhang, XL
    [J]. MICROCHIMICA ACTA, 2006, 153 (1-2) : 21 - 25
  • [49] Determination of nanomolar concentrations of phosphate in natural waters using flow injection with a long path length liquid waveguide capillary cell and solid-state spectrophotometric detection
    Gimbert, Laura J.
    Haygarth, Philip M.
    Worsfold, Paul J.
    [J]. TALANTA, 2007, 71 (04) : 1624 - 1628
  • [50] Electrothermal atomic absorption spectrometric determination of cobalt in biological samples and natural waters using a flow injection system with on-line preconcentration by ion-pair adsorption in a knotted reactor
    Karima Benkhedda
    Heidi Goenaga Infante
    E. Ivanova
    F. Adams
    [J]. Fresenius' Journal of Analytical Chemistry, 2000, 368 : 288 - 292