Characterization of the Discrepancies Between Four-Dimensional Phase-Contrast Magnetic Resonance Imaging and In-Silico Simulations of Cerebrospinal Fluid Dynamics

被引:18
|
作者
Pahlavian, Soroush Heidari [1 ]
Bunck, Alexander C. [2 ]
Loth, Francis [1 ]
Tubbs, R. Shane [3 ,4 ,5 ]
Yiallourou, Theresia [6 ]
Kroeger, Jan Robert [2 ]
Heindel, Walter [7 ]
Martin, Bryn A. [1 ]
机构
[1] Univ Akron, Dept Mech Engn, Conquer Chiari Res Ctr, Akron, OH 44325 USA
[2] Univ Hosp Cologne, Dept Radiol, D-50923 Cologne, Germany
[3] Childrens Alabama, Birmingham, AL 35233 USA
[4] St Georges Univ, Dept Anat Sci, St Georges, Grenada
[5] Univ Dundee, Ctr Anat & Human Identificat, Dundee DD1 4HN, Scotland
[6] Ecole Polytech Fed Lausanne, Lab Hemodynam & Cardiovasc Technol, CH-1015 Lausanne, Switzerland
[7] Univ Hosp Muenster, Dept Clin Radiol, D-48149 Munster, Germany
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2015年 / 137卷 / 05期
基金
瑞士国家科学基金会; 美国国家卫生研究院;
关键词
cerebrospinal fluid; computational fluid dynamics; 4D phase-contrast MRI; type 1 chiari malformation; hydrocephalus; spinal cord nerve root; denticulate ligament; spinal subarachnoid space; intrathecal drug delivery; CYCLIC CSF FLOW; SUBARACHNOID SPACE; FORAMEN MAGNUM; MICROSURGICAL ANATOMY; CHIARI MALFORMATION; SPINAL-CORD; MOTION; PRESSURE; JUNCTION; MODEL;
D O I
10.1115/1.4029699
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of the present study was to compare subject-specific magnetic resonance imaging (MRI)-based computational fluid dynamics (CFD) simulations with time-resolved three-directional (3D) velocity-encoded phase-contrast MRI (4D PCMRI) measurements of the cerebrospinal fluid (CSF) velocity field in the cervical spinal subarachnoid space (SSS). Three-dimensional models of the cervical SSS were constructed based on MRI image segmentation and anatomical measurements for a healthy subject and patient with Chiari I malformation. CFD was used to simulate the CSF motion and compared to the 4D PCMRI measurements. Four-dimensional PCMRI measurements had much greater CSF velocities compared to CFD simulations (1.4 to 5.6 x greater). Four-dimensional PCMRI and CFD both showed anterior and anterolateral dominance of CSF velocities, although this flow feature was more pronounced in 4D PCMRI measurements compared to CFD. CSF flow jets were present near the nerve rootlets and denticulate ligaments (NRDL) in the CFD simulation. Flow jets were visible in the 4D PCMRI measurements, although they were not clearly attributable to nerve rootlets. Inclusion of spinal cord NRDL in the cervical SSS does not fully explain the differences between velocities obtained from 4D PCMRI measurements and CFD simulations.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Quantitative Analysis of Cerebrospinal Fluid Flow in Complex Regions by Using Phase Contrast Magnetic Resonance Imaging
    Florez, Natalia
    Bouzerar, Roger
    Moratal, David
    Meyer, Marc-Etienne
    Marti-Bonmati, Luis
    Baledent, Olivier
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2011, 21 (03) : 290 - 297
  • [42] Semiautomatic Analysis of Phase Contrast Magnetic Resonance Imaging of Cerebrospinal Fluid Flow through the Aqueduct of Sylvius
    Yudy Natalia Flórez
    David Moratal
    Juana Forner
    Luis Martí-Bonmatí
    Estanislao Arana
    Ulises Guajardo-Hernández
    José Millet-Roig
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2006, 19 : 78 - 87
  • [43] Measurement of cerebrospinal fluid flow at the cerebral aqueduct by use of phase-contrast magnetic resonance imaging: Technique validation and utility in diagnosing idiopathic normal pressure hydrocephalus
    Luetmer, PH
    Huston, J
    Friedman, JA
    Dixon, GR
    Petersen, RC
    Jack, CR
    McClelland, RL
    Ebersold, MJ
    NEUROSURGERY, 2002, 50 (03) : 534 - 542
  • [44] Three-Dimensional Constructive Interference in Steady State Sequences and Phase-Contrast Magnetic Resonance Imaging of Arrested Hydrocephalus
    Elkafrawy, Fatma
    Reda, Ihab
    Elsirafy, Mohamed
    Gawad, Mohamed Saied Abdel
    Elnaggar, Alaa
    Razek, Ahmed Abdel Khalek Abdel
    WORLD NEUROSURGERY, 2017, 98 : 296 - 302
  • [45] Phase-Contrast Magnetic Resonance Imaging Measurements in Intracranial Aneurysms In Vivo of Flow Patterns, Velocity Fields, and Wall Shear Stress: Comparison with Computational Fluid Dynamics
    Boussel, Loic
    Rayz, Vitaliy
    Martin, Alastair
    Acevedo-Bolton, Gabriel
    Lawton, Michael T.
    Higashida, Randall
    Smith, Wade S.
    Young, William L.
    Saloner, David
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (02) : 409 - 417
  • [46] Post-Shunt Gait Improvement Correlates with Increased Cerebrospinal Fluid Peak Velocity in Normal Pressure Hydrocephalus: A Retrospective Observational Phase-Contrast Magnetic Resonance Imaging Study
    Miskin, Nityanand
    Serulle, Yafell
    Wu, William
    Bruno, Mary
    Damadian, Brianna
    Davis, Adam
    Golomb, James
    George, Ajax
    INTERNATIONAL JOURNAL OF SCIENTIFIC STUDY, 2015, 3 (08) : 48 - 54
  • [47] Intrathecal Contrast-Enhanced Magnetic Resonance Imaging of Cerebrospinal Fluid Dynamics and Glymphatic Enhancement in Idiopathic Normal Pressure Hydrocephalus
    Eide, Per Kristian
    Lashkarivand, Aslan
    Hagen-Kersten, Asmund Aleksander
    Gjertsen, Oivind
    Nedregaard, Bard
    Sletteberg, Ruth
    Lovland, Grethe
    Vatnehol, Svein Are Sirirud
    Pripp, Are Hugo
    Valnes, Lars Magnus
    Ringstad, Geir
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [48] Four-Dimensional Phase Contrast Magnetic Resonance Imaging Protocol Optimization Using Patient-Specific 3-Dimensional Printed Replicas for In Vivo Imaging Before and After Flow Diverter Placement
    Karmonik, Christof
    Anderson, Jeff R.
    Elias, Saba
    Klucznik, Richard
    Diaz, Orlando
    Zhang, Yi Jonathan
    Grossman, Robert G.
    Britz, Gavin W.
    WORLD NEUROSURGERY, 2017, 105 : 775 - 782
  • [49] Characterization of Maximum Wall Shear Stress Points in Unruptured Cerebral Aneurysms Using Four-dimensional Flow Magnetic Resonance Imaging
    Futami, Kazuya
    Misaki, Kouichi
    Uno, Takehiro
    Nambu, Iku
    Kamide, Tomoya
    Nakada, Mitsutoshi
    CLINICAL NEURORADIOLOGY, 2024, 34 (04) : 899 - 906
  • [50] Supratentorial cerebrospinal fluid production rate in healthy adults: Quantification with two-dimensional cine phase-contrast MR Imaging with high temporal and spatial resolution
    Huang, TY
    Chung, HW
    Chen, MY
    Giiang, LH
    Chin, SC
    Lee, CS
    Chen, CY
    Liu, YJ
    RADIOLOGY, 2004, 233 (02) : 603 - 608