Characterization of the Discrepancies Between Four-Dimensional Phase-Contrast Magnetic Resonance Imaging and In-Silico Simulations of Cerebrospinal Fluid Dynamics

被引:18
|
作者
Pahlavian, Soroush Heidari [1 ]
Bunck, Alexander C. [2 ]
Loth, Francis [1 ]
Tubbs, R. Shane [3 ,4 ,5 ]
Yiallourou, Theresia [6 ]
Kroeger, Jan Robert [2 ]
Heindel, Walter [7 ]
Martin, Bryn A. [1 ]
机构
[1] Univ Akron, Dept Mech Engn, Conquer Chiari Res Ctr, Akron, OH 44325 USA
[2] Univ Hosp Cologne, Dept Radiol, D-50923 Cologne, Germany
[3] Childrens Alabama, Birmingham, AL 35233 USA
[4] St Georges Univ, Dept Anat Sci, St Georges, Grenada
[5] Univ Dundee, Ctr Anat & Human Identificat, Dundee DD1 4HN, Scotland
[6] Ecole Polytech Fed Lausanne, Lab Hemodynam & Cardiovasc Technol, CH-1015 Lausanne, Switzerland
[7] Univ Hosp Muenster, Dept Clin Radiol, D-48149 Munster, Germany
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2015年 / 137卷 / 05期
基金
瑞士国家科学基金会; 美国国家卫生研究院;
关键词
cerebrospinal fluid; computational fluid dynamics; 4D phase-contrast MRI; type 1 chiari malformation; hydrocephalus; spinal cord nerve root; denticulate ligament; spinal subarachnoid space; intrathecal drug delivery; CYCLIC CSF FLOW; SUBARACHNOID SPACE; FORAMEN MAGNUM; MICROSURGICAL ANATOMY; CHIARI MALFORMATION; SPINAL-CORD; MOTION; PRESSURE; JUNCTION; MODEL;
D O I
10.1115/1.4029699
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of the present study was to compare subject-specific magnetic resonance imaging (MRI)-based computational fluid dynamics (CFD) simulations with time-resolved three-directional (3D) velocity-encoded phase-contrast MRI (4D PCMRI) measurements of the cerebrospinal fluid (CSF) velocity field in the cervical spinal subarachnoid space (SSS). Three-dimensional models of the cervical SSS were constructed based on MRI image segmentation and anatomical measurements for a healthy subject and patient with Chiari I malformation. CFD was used to simulate the CSF motion and compared to the 4D PCMRI measurements. Four-dimensional PCMRI measurements had much greater CSF velocities compared to CFD simulations (1.4 to 5.6 x greater). Four-dimensional PCMRI and CFD both showed anterior and anterolateral dominance of CSF velocities, although this flow feature was more pronounced in 4D PCMRI measurements compared to CFD. CSF flow jets were present near the nerve rootlets and denticulate ligaments (NRDL) in the CFD simulation. Flow jets were visible in the 4D PCMRI measurements, although they were not clearly attributable to nerve rootlets. Inclusion of spinal cord NRDL in the cervical SSS does not fully explain the differences between velocities obtained from 4D PCMRI measurements and CFD simulations.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Cerebrospinal fluid flow dynamics in patients with multiple sclerosis: a phase contrast magnetic resonance study
    Gorucu, Yasin
    Albayram, Sait
    Balci, Belgin
    Hasiloglu, Zehra Isik
    Yenigul, Kubilay
    Yargic, Fatma
    Keser, Zafer
    Kantarci, Fatih
    Kiris, Adem
    FUNCTIONAL NEUROLOGY, 2011, 26 (04) : 215 - 222
  • [32] Minimizing the blood velocity differences between phase-contrast magnetic resonance imaging and computational fluid dynamics simulation in cerebral arteries and aneurysms
    Adib, Mohd Azrul Hisham Mohd
    Ii, Satoshi
    Watanabe, Yoshiyuki
    Wada, Shigeo
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (09) : 1605 - 1619
  • [33] Minimizing the blood velocity differences between phase-contrast magnetic resonance imaging and computational fluid dynamics simulation in cerebral arteries and aneurysms
    Mohd Azrul Hisham Mohd Adib
    Satoshi Ii
    Yoshiyuki Watanabe
    Shigeo Wada
    Medical & Biological Engineering & Computing, 2017, 55 : 1605 - 1619
  • [34] Quantifying Hemodynamic Changes in Moyamoya Disease Based on Two-Dimensional Cine Phase-Contrast Magnetic Resonance Imaging and Computational Fluid Dynamics
    Sun, Wenbo
    Ruan, Zhao
    Dai, Xuan
    Li, Sirui
    Li, Shuo
    Zhang, Jianjian
    Chen, Jincao
    Zhang, Heye
    Xu, Haibo
    WORLD NEUROSURGERY, 2018, 120 : E1301 - E1309
  • [35] FLOW DYNAMICS OF CEREBROSPINAL-FLUID - ASSESSMENT WITH PHASE-CONTRAST VELOCITY MR IMAGING PERFORMED WITH RETROSPECTIVE CARDIAC GATING
    NITZ, WR
    BRADLEY, WG
    WATANABE, AS
    LEE, RR
    BURGOYNE, B
    OSULLIVAN, RM
    HERBST, MD
    RADIOLOGY, 1992, 183 (02) : 395 - 405
  • [36] Evaluation of the flow of cerebrospinal fluid as well as gender and age characteristics in patients with communicating hydrocephalus, using phase-contrast magnetic resonance imaging
    Olga Bogomyakova
    Yu. Stankevich
    N. Mesropyan
    L. Shaybman
    A. Tulupov
    Acta Neurologica Belgica, 2016, 116 : 495 - 501
  • [37] Evaluation of the flow of cerebrospinal fluid as well as gender and age characteristics in patients with communicating hydrocephalus, using phase-contrast magnetic resonance imaging
    Bogomyakova, Olga
    Stankevich, Yu.
    Mesropyan, N.
    Shaybman, L.
    Tulupov, A.
    ACTA NEUROLOGICA BELGICA, 2016, 116 (04) : 495 - 501
  • [38] Cerebrospinal fluid flow in empty sella syndrome and normal sellar regions measured by phase-contrast quantitative magnetic resonance
    Hu, Weidong
    Xiang, Li
    Wang, Xiurong
    NEURAL REGENERATION RESEARCH, 2011, 6 (11) : 816 - 820
  • [40] Semiautomatic analysis of phase contrast magnetic resonance imaging of cerebrospinal fluid flow through the aqueduct of Sylvius
    Florez, Yudy Natalia
    Moratal, David
    Forner, Juana
    Marti-Bonmati, Luis
    Arana, Estanislao
    Guajardo-Hernandez, Ulises
    Millet-Roig, Jose