Characterization of the Discrepancies Between Four-Dimensional Phase-Contrast Magnetic Resonance Imaging and In-Silico Simulations of Cerebrospinal Fluid Dynamics

被引:18
|
作者
Pahlavian, Soroush Heidari [1 ]
Bunck, Alexander C. [2 ]
Loth, Francis [1 ]
Tubbs, R. Shane [3 ,4 ,5 ]
Yiallourou, Theresia [6 ]
Kroeger, Jan Robert [2 ]
Heindel, Walter [7 ]
Martin, Bryn A. [1 ]
机构
[1] Univ Akron, Dept Mech Engn, Conquer Chiari Res Ctr, Akron, OH 44325 USA
[2] Univ Hosp Cologne, Dept Radiol, D-50923 Cologne, Germany
[3] Childrens Alabama, Birmingham, AL 35233 USA
[4] St Georges Univ, Dept Anat Sci, St Georges, Grenada
[5] Univ Dundee, Ctr Anat & Human Identificat, Dundee DD1 4HN, Scotland
[6] Ecole Polytech Fed Lausanne, Lab Hemodynam & Cardiovasc Technol, CH-1015 Lausanne, Switzerland
[7] Univ Hosp Muenster, Dept Clin Radiol, D-48149 Munster, Germany
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2015年 / 137卷 / 05期
基金
瑞士国家科学基金会; 美国国家卫生研究院;
关键词
cerebrospinal fluid; computational fluid dynamics; 4D phase-contrast MRI; type 1 chiari malformation; hydrocephalus; spinal cord nerve root; denticulate ligament; spinal subarachnoid space; intrathecal drug delivery; CYCLIC CSF FLOW; SUBARACHNOID SPACE; FORAMEN MAGNUM; MICROSURGICAL ANATOMY; CHIARI MALFORMATION; SPINAL-CORD; MOTION; PRESSURE; JUNCTION; MODEL;
D O I
10.1115/1.4029699
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of the present study was to compare subject-specific magnetic resonance imaging (MRI)-based computational fluid dynamics (CFD) simulations with time-resolved three-directional (3D) velocity-encoded phase-contrast MRI (4D PCMRI) measurements of the cerebrospinal fluid (CSF) velocity field in the cervical spinal subarachnoid space (SSS). Three-dimensional models of the cervical SSS were constructed based on MRI image segmentation and anatomical measurements for a healthy subject and patient with Chiari I malformation. CFD was used to simulate the CSF motion and compared to the 4D PCMRI measurements. Four-dimensional PCMRI measurements had much greater CSF velocities compared to CFD simulations (1.4 to 5.6 x greater). Four-dimensional PCMRI and CFD both showed anterior and anterolateral dominance of CSF velocities, although this flow feature was more pronounced in 4D PCMRI measurements compared to CFD. CSF flow jets were present near the nerve rootlets and denticulate ligaments (NRDL) in the CFD simulation. Flow jets were visible in the 4D PCMRI measurements, although they were not clearly attributable to nerve rootlets. Inclusion of spinal cord NRDL in the cervical SSS does not fully explain the differences between velocities obtained from 4D PCMRI measurements and CFD simulations.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Changing concepts of cerebrospinal fluid hydrodynamics: Role of phase-contrast magnetic resonance imaging and implications for cerebral microvascular disease
    Stivaros, Stavros Michael
    Jackson, Alan
    NEUROTHERAPEUTICS, 2007, 4 (03) : 511 - 522
  • [22] Characterization of cardiac- and respiratory-driven cerebrospinal fluid motion based on asynchronous phase-contrast magnetic resonance imaging in volunteers
    Ken Takizawa
    Mitsunori Matsumae
    Saeko Sunohara
    Satoshi Yatsushiro
    Kagayaki Kuroda
    Fluids and Barriers of the CNS, 14
  • [23] Characterization of cardiac- and respiratory-driven cerebrospinal fluid motion based on asynchronous phase-contrast magnetic resonance imaging in volunteers
    Takizawa, Ken
    Matsumae, Mitsunori
    Sunohara, Saeko
    Yatsushiro, Satoshi
    Kuroda, Kagayaki
    FLUIDS AND BARRIERS OF THE CNS, 2017, 14
  • [24] Before and after Endovascular Aortic Repair in the Same Patients with Aortic Dissection: A Cohort Study of Four-Dimensional Phase-Contrast Magnetic Resonance Imaging
    Chen, Chien-Wei
    Fang, Yueh-Fu
    Tseng, Yuan-Hsi
    Wong, Min Yi
    Lin, Yu-Hui
    Hsu, Yin-Chen
    Lin, Bor-Shyh
    Huang, Yao-Kuang
    DIAGNOSTICS, 2021, 11 (10)
  • [25] Comparison of 4D Phase-Contrast MRI Flow Measurements to Computational Fluid Dynamics Simulations of Cerebrospinal Fluid Motion in the Cervical Spine
    Yiallourou, Theresia I.
    Kroeger, Jan Robert
    Stergiopulos, Nikolaos
    Maintz, David
    Martin, Bryn A.
    Bunck, Alexander C.
    PLOS ONE, 2012, 7 (12):
  • [26] Hemodynamic analysis of intracranial aneurysms using phase-contrast magnetic resonance imaging and computational fluid dynamics
    Zhao, Xuemei
    Li, Rui
    Chen, Yu
    Sia, Sheau Fung
    Li, Donghai
    Zhang, Yu
    Liu, Aihua
    ACTA MECHANICA SINICA, 2017, 33 (02) : 472 - 483
  • [27] Cerebrospinal Fluid Flow Dynamics in Multiple Sclerosis Patients through Phase Contrast Magnetic Resonance Imaging
    Lagana, Maria Marcella
    Chaudhary, Anamika
    Balagurunathan, Deepa
    Utriainen, David
    Kokeny, Paul
    Feng, Wei
    Cecconi, Pietro
    Hubbard, David
    Haacke, E. Mark
    CURRENT NEUROVASCULAR RESEARCH, 2014, 11 (04) : 349 - 358
  • [28] Variation in supratentorial cerebrospinal fluid production rate in one day: measurement by nontriggered phase-contrast magnetic resonance imaging
    Hiroto Takahashi
    Hisashi Tanaka
    Norihiko Fujita
    Kenya Murase
    Noriyuki Tomiyama
    Japanese Journal of Radiology, 2011, 29 : 110 - 115
  • [29] Quantitative analysis of cerebrospinal fluid flow in patients with cervical spondylosis using cine phase-contrast magnetic resonance imaging
    Watabe, N
    Tominaga, T
    Shimizu, H
    Koshu, K
    Yoshimoto, T
    NEUROSURGERY, 1999, 44 (04) : 779 - 784
  • [30] Characterization of intrathecal cerebrospinal fluid geometry and dynamics in cynomolgus monkeys (macaca fascicularis) by magnetic resonance imaging
    Khani, Mohammadreza
    Lawrence, Braden J.
    Sass, Lucas R.
    Gibbs, Christina P.
    Pluid, Joshua J.
    Oshinski, John N.
    Stewart, Gregory R.
    Zeller, Jillynne R.
    Martin, Bryn A.
    PLOS ONE, 2019, 14 (02):