Instrumental and randomised clinical comparison between laryngeal mask airway Proseal and Supreme in pediatric patients

被引:0
|
作者
Santambrogio, Luisa [1 ]
Righi, Sabrina [1 ]
Pinciroli, Rosa L. [1 ]
Piro, Eugenia [2 ]
D'alessio, Antonio [2 ]
Minuto, Aldo [1 ]
机构
[1] ASST Ovestmilanese Civil Hosp Legnano, Anesthesia & Intens Care Dept, Via Papa Giovanni Paolo 2, I-20025 Milan, Italy
[2] ASST Ovestmilanese Civil Hosp Legnano, Pediat Surg Dept, Via Papa Giovanni Paolo 2, I-20025 Milan, Italy
关键词
Laryngeal mask airway; Child; Mechanical ventilation; General anesthesia; Airway management; Supraglottic device; OROPHARYNGEAL LEAK PRESSURE; LMA SUPREME(TM); COHORT EVALUATION; CHILDREN; DEVICES; ANESTHESIA; MANAGEMENT; INSERTION;
D O I
10.1016/j.tacc.2019.11.001
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Laryngeal mask airway (LMA) has proven safe and effective for airway management in children during general anesthesia; mostly the second generation LMAs, none of which resulted clearly better despite previous studies. Aim: Proseal-LMA (PLMA) and Supreme-LMA (SLMA) are compared for structural characteristics and oropharyngeal leak pressure as primary aims, and mechanical ventilation, insertion, intra- and postoperative complications as secondary aims. Trial design: prospective randomised parallel clinical trial. Methods: instrumental evaluation: measurements of length, cross section, loading test on free air were performed to assess the resistance during ventilation. Then, 39 children received PLMA and 39 received SLMA for airway management during elective surgery: intraoperative and postoperative data were analyzed. Results: transversal section area was 35,71 mm(2) in PLMA and 59,61 in SLMA, whilst length was 133,67 and 123,07 mm; the loading test on free air confirmed lower resistance of SLMA. Oropharyngeal leak pressure resulted significant lower in SLMA. No significant difference in other clinical parameters and complications. Conclusions: instrumental measurements highlight that SLMA offers the advantage of less resistance to the airflow, allowing to keep lower oropharyngeal leak pressure during mechanical ventilation. Despite the differences reported, we observed only a few minor complications in both groups. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:14 / 21
页数:8
相关论文
共 50 条
  • [1] Comparison of Supreme Laryngeal Mask Airway and ProSeal Laryngeal Mask Airway during Cholecystectomy
    Hosten, Tulay
    Yildiz, Tulay Sahin
    Kus, Alparslan
    Solak, Mine
    Toker, Kamil
    BALKAN MEDICAL JOURNAL, 2012, 29 (03) : 314 - 319
  • [2] Safety and efficacy of laryngeal mask airway Supreme versus laryngeal mask airway ProSeal: a randomized controlled trial
    Seet, Edwin
    Rajeev, Subramanyam
    Firoz, Tamal
    Yousaf, Farhanah
    Wong, Jean
    Wong, David T.
    Chung, Frances
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (07) : 602 - 607
  • [3] Comparison of the Supreme™ and ProSeal™ laryngeal mask airways in infants: a prospective randomised clinical study
    Oba, Sibel
    Turk, Hacer Sebnem
    Isil, Canan Tulay
    Erdogan, Huseyin
    Sayin, Pinar
    Dokucu, Ali Ihsan
    BMC ANESTHESIOLOGY, 2017, 17
  • [4] Comparison between i-gel airway an the proseal laryngeal mask airway in pediatric patients undergoing general anesthesia
    Acharya, R.
    Dave, N. M.
    PEDIATRIC ANESTHESIA AND CRITICAL CARE JOURNAL, 2016, 4 (02): : 97 - 102
  • [5] Comparison of the laryngeal mask airway Supreme and laryngeal mask airway Classic in adults
    Ali, Achmet
    Canturk, Selcuk
    Turkmen, Aygen
    Turgut, Namigar
    Altan, Aysel
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2009, 26 (12) : 1010 - 1014
  • [6] A cohort evaluation of the pediatric ProSeal laryngeal mask airway in 100 children
    Kelly, Fiona
    Sale, Steven
    Bayley, Guy
    Cook, Tim
    Stoddart, Peter
    White, Michelle
    PEDIATRIC ANESTHESIA, 2008, 18 (10) : 947 - 951
  • [7] Comparison between I-Gel and Classic Laryngeal Mask Airway for Airway Management of Patients with Anticipated Difficult Airway: A Randomised Clinical Trial
    Raman, Rajesh
    Gautam, Shefali
    Sonkar, Suraj
    Prabha, Rati
    Alam, Sharif
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (10) : UC10 - UC13
  • [8] The ProSeal™ laryngeal mask airway in children
    Lopez-Gil, M
    Brimacombe, J
    PEDIATRIC ANESTHESIA, 2005, 15 (03) : 229 - 234
  • [9] A randomized comparison of the i-gel and the ProSeal laryngeal mask airway in pediatric patients: performance and fiberoptic findings
    Fukuhara, Aya
    Okutani, Ryu
    Oda, Yutaka
    JOURNAL OF ANESTHESIA, 2013, 27 (01) : 1 - 6
  • [10] The supraglottic airway I-gel in comparison with ProSeal laryngeal mask airway and classic laryngeal mask airway in anaesthetized patients
    Shin, Won-Jung
    Cheong, Yu-Seon
    Yang, Hong-Seuk
    Nishiyama, Tomoki
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (07) : 598 - 601