Non-invasive cardiac output determination: Comparison of a new partial-rebreathing technique with thermodilution

被引:28
|
作者
Binder, JC
Parkin, WG
机构
[1] Monash Med Ctr, Dept Resp Med, Melbourne, Vic, Australia
[2] Monash Med Ctr, Dept Intens Care, Melbourne, Vic, Australia
[3] Monash Univ, Ctr Heart & Chest Res, Melbourne, Vic 3004, Australia
关键词
cardiac output; measurement; fick; differential; derivative;
D O I
10.1177/0310057X0102900103
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This study compares a derivative Fick technique using carbon dioxide (CO2) with the thermodilution pulmonary artery catheter (PAC), for determination of cardiac output (CO). Subjects were sedated mechanically ventilated adults following elective cardiac surgery. Microprocessor controlled deadspace activation and side-stream capnography in a ventilator circuit enabled calculation of CO (COCO2) every four minutes. Thermodilution CO (COTD) was performed as clinically indicated and at 20-minute intervals. Simultaneous COTD/COCO2 pairs were recorded from time of admission to ICU for a minium period of two hours for each patient. There were 358 COTD/COCO2 pairs recorded from 41 patients. Cardiac output measurements ranged from 2.7 to 10.6 l/min. The bias (Bland-Altman) was 0.050 l/min (95% CI -0.024 to 0.125 l/min). The 95% limits of agreement were -1.354 to 1.455 l/min. This simple, non-invasive partial-rebreathing technique is a valid alternative to thermodilution for car dine output determination in sedated mechanically ventilated patients. There are significant implications for improved safety reduced complexity and reduced cost in anaesthesia and intensive care.
引用
收藏
页码:19 / 23
页数:5
相关论文
共 50 条
  • [21] A new non-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors: Comparison with the continuous thermodilution method early cardiovascular monitors
    Ishihara H.
    Okawa H.
    Tanabe K.
    Tsubo T.
    Sugo Y.
    Akiyama T.
    Takeda S.
    Journal of Clinical Monitoring and Computing, 2004, 18 (5-6) : 313 - 320
  • [22] Non-invasive measurement of cardiac output: whole-body impedance cardiography in simultaneous comparison with thermodilution and direct oxygen Fick methods
    Koobi, T
    Kaukinen, S
    Ahola, T
    Turjanmaa, VMH
    INTENSIVE CARE MEDICINE, 1997, 23 (11) : 1132 - 1137
  • [23] Non-invasive measurement of cardiac output: whole-body impedance cardiography in simultaneous comparison with thermodilution and direct oxygen Fick methods
    T. Kööbi
    S. Kaukinen
    T. Ahola
    V. M. H. Turjanmaa
    Intensive Care Medicine, 1997, 23 : 1132 - 1137
  • [24] Comparison of bioreactance non-invasive cardiac output measurements with cardiac magnetic resonance imaging
    Trinkmann, F.
    Schneider, C.
    Michels, J. D.
    Stach, K.
    Doesch, C.
    Schoenberg, S. O.
    Borggrefe, M.
    Saur, J.
    Papavassiliu, T.
    ANAESTHESIA AND INTENSIVE CARE, 2016, 44 (06) : 769 - 776
  • [25] Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output
    Kurita, T
    Morita, K
    Kato, S
    Kikura, M
    Horie, M
    Ikeda, K
    BRITISH JOURNAL OF ANAESTHESIA, 1997, 79 (06) : 770 - 775
  • [26] Non-invasive assessment of cardiac output in children
    Richardson, JR
    Ferguson, J
    Hiscox, J
    Rawles, J
    JOURNAL OF ACCIDENT & EMERGENCY MEDICINE, 1998, 15 (05): : 304 - 307
  • [27] A comparison of three minimally invasive cardiac output devices with thermodilution in elective cardiac surgery
    Phan, T. D.
    Kluger, R.
    Wan, C.
    Wong, D.
    Padayachee, A.
    ANAESTHESIA AND INTENSIVE CARE, 2011, 39 (06) : 1014 - 1021
  • [28] Influence of systemic vascular resistance on cardiac output measured by new non-invasive cardiac output monitor
    K Yamashita
    T Yamatabe
    H Abe
    M Yokoyama
    Critical Care, 14 (Suppl 1):
  • [29] A comparison of the use of transoesophageal Doppler and thermodilution techniques for cardiac output determination
    Keyl, C
    Rodig, G
    Lemberger, P
    Hobbhahn, J
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1996, 13 (02) : 136 - 142
  • [30] Non-invasive cardiac output evaluation in postoperative cardiac surgery patients, using a new prolonged expiration-based technique
    Alessia Mattei
    Emiliano Schena
    Stefano Cecchini
    Paola Proscia
    Paola Saccomandi
    Sergio Silvestri
    Massimiliano Carassiti
    Journal of Clinical Monitoring and Computing, 2014, 28 : 625 - 632