Non-invasive cardiac output determination: Comparison of a new partial-rebreathing technique with thermodilution

被引:28
|
作者
Binder, JC
Parkin, WG
机构
[1] Monash Med Ctr, Dept Resp Med, Melbourne, Vic, Australia
[2] Monash Med Ctr, Dept Intens Care, Melbourne, Vic, Australia
[3] Monash Univ, Ctr Heart & Chest Res, Melbourne, Vic 3004, Australia
关键词
cardiac output; measurement; fick; differential; derivative;
D O I
10.1177/0310057X0102900103
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This study compares a derivative Fick technique using carbon dioxide (CO2) with the thermodilution pulmonary artery catheter (PAC), for determination of cardiac output (CO). Subjects were sedated mechanically ventilated adults following elective cardiac surgery. Microprocessor controlled deadspace activation and side-stream capnography in a ventilator circuit enabled calculation of CO (COCO2) every four minutes. Thermodilution CO (COTD) was performed as clinically indicated and at 20-minute intervals. Simultaneous COTD/COCO2 pairs were recorded from time of admission to ICU for a minium period of two hours for each patient. There were 358 COTD/COCO2 pairs recorded from 41 patients. Cardiac output measurements ranged from 2.7 to 10.6 l/min. The bias (Bland-Altman) was 0.050 l/min (95% CI -0.024 to 0.125 l/min). The 95% limits of agreement were -1.354 to 1.455 l/min. This simple, non-invasive partial-rebreathing technique is a valid alternative to thermodilution for car dine output determination in sedated mechanically ventilated patients. There are significant implications for improved safety reduced complexity and reduced cost in anaesthesia and intensive care.
引用
收藏
页码:19 / 23
页数:5
相关论文
共 50 条
  • [1] Non-invasive determination of cardiac output: Comparison of a novel CW Doppler ultrasonic technique and inert gas rebreathing
    Saur, Joachim
    Trinkmann, Frederik
    Weissmann, Joerg
    Borggrefe, Martin
    Kaden, Jens J.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 136 (02) : 248 - 250
  • [2] Partial CO2 rebreathing indirect fick technique for non-invasive measurement of cardiac output
    Haryadi, DG
    Orr, JA
    Kuck, K
    McJames, S
    Westenskow, DR
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2000, 16 (5-6) : 361 - 374
  • [3] Partial CO2 Rebreathing Indirect Fick Technique for Non-Invasive Measurement of Cardiac Output
    Dinesh G. Haryadi
    Joseph A. Orr
    Kai Kuck
    Scott McJames
    Dwayne R. Westenskow
    Journal of Clinical Monitoring and Computing, 2000, 16 : 361 - 374
  • [4] Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique
    Gabrielsen, A
    Videbæk, R
    Schou, M
    Damgaard, M
    Kastrup, J
    Norsk, P
    CLINICAL SCIENCE, 2002, 102 (02) : 247 - 252
  • [5] Non-Invasive Cardiac Output Determination Using Magnetic Resonance Imaging and Thermodilution in Pulmonary Hypertension
    Crowe, Lindsey A.
    Genecand, Leon
    Hachulla, Anne-Lise
    Noble, Stephane
    Beghetti, Maurice
    Vallee, Jean-Paul
    Lador, Frederic
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (10)
  • [6] COMPARISON OF ACETYLENE REBREATHING AND THERMODILUTION METHODS FOR DETERMINING CARDIAC-OUTPUT
    OCHI, H
    MORIOKA, S
    YANO, S
    UMENO, T
    NAGANUMA, S
    IKUMA, I
    MATSUNO, Y
    IZUMI, S
    MURAKAMI, R
    MORIYAMA, K
    AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1991, 5 (02): : 106 - 109
  • [7] Non-invasive cardiac output by transthoracic electrical bioimpedence in post-cardiac surgery patients: Comparison with thermodilution method
    Gujjar A.R.
    Muralidhar K.
    Banakal S.
    Gupta R.
    Sathyaprabha T.N.
    Jairaj P.S.
    Journal of Clinical Monitoring and Computing, 2008, 22 (03) : 175 - 180
  • [8] Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients
    董樑
    王建安
    蒋晨阳
    Journal of Zhejiang University Science, 2005, (12) : 1157 - 1162
  • [9] Novel non-invasive technology for cardiac output determination
    U Borg
    D Iyer
    Q Huang
    Y Li
    C Baker
    Critical Care, 18 (Suppl 1):
  • [10] Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output
    Trinkmann, Frederik
    Berger, Manuel
    Doesch, Christina
    Papavassiliu, Theano
    Schoenberg, Stefan O.
    Borggrefe, Martin
    Kaden, Jens J.
    Saur, Joachim
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (04) : 399 - 408