Early failure of a roughened surface, precoated femoral component in total hip arthroplasty

被引:46
|
作者
Sylvain, GM [1 ]
Kassab, S [1 ]
Coutts, R [1 ]
Santore, R [1 ]
机构
[1] Orthopaed Specialists Nevada, Joint Reconstruct Div, Las Vegas, NV 89106 USA
关键词
hip arthroplasty; precoated; roughened surface; early failure; femoral prosthesis;
D O I
10.1054/arth.2001.20541
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A retrospective study was performed of a consecutive series examining 98 primary hip arthroplasties between March 1992 and December 1995. A second-generation roughened surface (grit-blasted), polymethyl methacrylare-precoated femoral component (Centralign prosthesis, Zimmer. Inc, Warsaw, IN) was used for all cases. Clinical and radiographic data were available for 84 hips (76 patients). The average duration of follow-up was 35.8 months. There were 10 failures by aseptic mechanical loosening of the femoral component (12%) at an average 30.6 months postoperatively, 9 having been revised (11%). Revision was pending in the remaining patient. The average age of patients at primary arthroplasty for the failed group was 48.2 years compared with 63.4 years for the asymptomatic patients (P = .0008). In all cases, failures occurred by debonding of the femoral prosthesis from the cement mantle. We are not aware of any series using modern implant components and cementing techniques with an early mechanical failure rate of this magnitude.
引用
收藏
页码:141 / 148
页数:8
相关论文
共 50 条
  • [21] Influence of surgical approach on component positioning in primary total hip arthroplasty
    Moritz M. Innmann
    Marcus R. Streit
    Jeanette Kolb
    Jochen Heiland
    Dominik Parsch
    Peter R. Aldinger
    Matthias Königshausen
    Tobias Gotterbarm
    Christian Merle
    BMC Musculoskeletal Disorders, 16
  • [22] Primary cementless total hip arthroplasty using a modular femoral component - A minimum 6-year follow-up
    Tanzer, M
    Chan, S
    Brooks, CE
    Bobyn, JD
    JOURNAL OF ARTHROPLASTY, 2001, 16 (08) : 64 - 70
  • [23] Total hip arthroplasty reduces the risk of dislocation after femoral neck fracture
    Pangaud, Corentin
    Pioger, Charles
    Pauly, Vanessa
    Orleans, Veronica
    Boyer, Laurent
    Argenson, Jean Noel
    Ollivier, Matthieu
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2023, 109 (04)
  • [24] A comparison of collared and collarless femoral components in primary cemented total hip arthroplasty
    Meding, JB
    Ritter, MA
    Keating, EM
    Faris, PM
    Edmondson, K
    JOURNAL OF ARTHROPLASTY, 1999, 14 (02) : 123 - 130
  • [25] Clinical outcome in total hip arthroplasty using a cemented titanium femoral prosthesis
    Jergesen, HE
    Karlen, JW
    JOURNAL OF ARTHROPLASTY, 2002, 17 (05) : 592 - 599
  • [26] Fracture of the femoral head after ceramic-on-polyethylene total hip arthroplasty
    Callaway, GH
    Flynn, W
    Ranawat, CS
    Sculco, TP
    JOURNAL OF ARTHROPLASTY, 1995, 10 (06) : 855 - 859
  • [27] Radiographic Characteristics of the Femoral Nutrient Artery Canals in Total Hip Arthroplasty using Cementless Femoral Stem
    Roh, Y. H.
    Yoo, S. J.
    Choi, T. H.
    Nam, K. W.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2023, 17 (01) : 124 - 132
  • [28] Zirconia Phase Transformation, Metal Transfer, and Surface Roughness in Retrieved Ceramic Composite Femoral Heads in Total Hip Arthroplasty
    Elpers, Marcella
    Nam, Denis
    Boydston-White, Susie
    Ast, Michael P.
    Wright, Timothy M.
    Padgett, Douglas E.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (11) : 2219 - 2223
  • [29] Augmented Reality for Acetabular Component Placement in Direct Anterior Total Hip Arthroplasty
    Alexander, Clayton
    Loeb, Alexander E.
    Fotouhi, Javad
    Navab, Nassir
    Armand, Mehran
    Khanuja, Harpal S.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (06) : 1636 - +
  • [30] Dislocation after total hip arthroplasty with 28 and 32-mm femoral head
    Amlie E.
    Høvik O.
    Reikerås O.