A retrospective study was performed of a consecutive series examining 98 primary hip arthroplasties between March 1992 and December 1995. A second-generation roughened surface (grit-blasted), polymethyl methacrylare-precoated femoral component (Centralign prosthesis, Zimmer. Inc, Warsaw, IN) was used for all cases. Clinical and radiographic data were available for 84 hips (76 patients). The average duration of follow-up was 35.8 months. There were 10 failures by aseptic mechanical loosening of the femoral component (12%) at an average 30.6 months postoperatively, 9 having been revised (11%). Revision was pending in the remaining patient. The average age of patients at primary arthroplasty for the failed group was 48.2 years compared with 63.4 years for the asymptomatic patients (P = .0008). In all cases, failures occurred by debonding of the femoral prosthesis from the cement mantle. We are not aware of any series using modern implant components and cementing techniques with an early mechanical failure rate of this magnitude.
引用
收藏
页码:141 / 148
页数:8
相关论文
共 50 条
  • [1] Precoated femoral component in primary hybrid total hip arthroplasty - Results at a mean 10-year follow-up
    Lachiewicz, PF
    Messick, P
    JOURNAL OF ARTHROPLASTY, 2003, 18 (01) : 1 - 5
  • [2] Primary hybrid total hip arthroplasty with a roughened femoral stem: Integrity of the stem-cement interface
    Meneghini, RM
    Feinberg, JR
    Capello, WN
    JOURNAL OF ARTHROPLASTY, 2003, 18 (03) : 299 - 307
  • [3] Early failure of a proximally cemented, distally uncemented total hip arthroplasty
    Vora, A
    Kudrna, JC
    Harder, VS
    Mazahery, B
    JOURNAL OF ARTHROPLASTY, 2003, 18 (07) : 889 - 896
  • [4] The timing of femoral component insertion in cemented hip arthroplasty
    McWilliams, TG
    Binns, MS
    JOURNAL OF ARTHROPLASTY, 2003, 18 (01) : 51 - 55
  • [5] Periprosthetic femoral fractures in total hip arthroplasty - a review
    Rayan, Faizal
    Haddad, Fares
    HIP INTERNATIONAL, 2010, 20 (04) : 418 - 426
  • [6] Catastrophic failure of the acetabular component in a ceramic-polyethylene bearing total hip arthroplasty
    Simon, JA
    Dayan, AJ
    Ergas, E
    Stuchin, SA
    Di Cesare, PE
    JOURNAL OF ARTHROPLASTY, 1998, 13 (01) : 108 - 113
  • [7] Failure after customized curved femoral stems in total hip arthroplasty for Paget's disease
    Dunlop, DJ
    Donnachie, NJ
    Treacy, RBC
    JOURNAL OF ARTHROPLASTY, 2000, 15 (03) : 398 - 401
  • [8] Primary total hip arthroplasty with an uncemented femoral component - A long-term study of the Taperloc stem
    Parvizi, J
    Keisu, KS
    Hozack, WJ
    Sharkey, PF
    Rothman, RH
    JOURNAL OF ARTHROPLASTY, 2004, 19 (02) : 151 - 156
  • [9] Primary Total Hip Arthroplasty With an Uncemented Femoral Component Five- to Nine-Year Results
    Casper, David S.
    Kim, Gregory K.
    Restrepo, Camilo
    Parvizi, Javad
    Rothman, Richard H.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (06) : 838 - 841
  • [10] Influence of surface finish in total hip arthroplasty
    Vaughn, BK
    Fuller, E
    Peterson, R
    Capps, SG
    JOURNAL OF ARTHROPLASTY, 2003, 18 (07) : 110 - 115