Analysis of artifacts found in endographic visualization of spiral CT scans.

被引:9
作者
Bode, A
Dammann, F
Pelikan, EHW
Heuschmid, M
Schwaderer, E
Schaich, M
Claussen, CD
机构
[1] Univ Tubingen, Radiol Klin, Abt Radiol Diagnost, D-72076 Tubingen, Germany
[2] Philips Med Syst Hamburg, Hamburg, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2001年 / 173卷 / 03期
关键词
CT; three-dimensional; image processing; artifact; phantoms;
D O I
10.1055/s-2001-11758
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Analysis of patterns and causes of artifacts found in endographic visualization of spiral CT data. Materials and methods: A straight perspex tube with a diameter of 20 mm was scanned in three different positions with ten scan protocols of varying table feed, increment, kernel, and signal to noise ratio (Tomoscan AVE, Philips). The resulting 30 CT datasets were visualized as a virtual endoscopy (VE) with ten different visualization protocols (Easy Vision 4.2, Philips) of varying threshold, resolution, and perspective angle. 300 VE datasets were analyzed by two radiologists and compared with the Visualization of a software-generated tube in order to differentiate scanning and software artifacts. Results: Five different classes of artifacts have been identified. Two of them result from the scanning process and two from the specific Visualization method. Spiral patterns and the unevenness of the tube wall vary with the scanning parameter. Moire-like patterns are caused by the VE software and depend on the visualization matrix. A high perspective angle distorts the size and form of the tube and makes it difficult for the observer to locate his position within the tube. The appearance of pseudoforamina depends on both the scanning and the visualization parameters. Conclusion: The knowledge of the patterns and potential causes of artifacts in endographic Visualization of spiral CT scans are the basis for interpretation and optimization of this visualization method.
引用
收藏
页码:245 / 252
页数:8
相关论文
共 25 条
  • [1] Diagnostic accuracy and therapeutic relevance of CT arthrography and MR arthrography of the shoulder joint
    Bachmann, G
    Bauer, T
    Jurgensen, I
    Schwab, J
    Weimar, B
    Rau, WS
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (02): : 149 - 156
  • [2] Vitro examinations for detection of vascular stenoses using spiral CT angiography.
    Beilicke, M
    Kloppel, R
    Lieberenz, S
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (03): : 217 - 221
  • [3] FIDELITY OF 3-DIMENSIONAL CT IMAGING FOR DETECTING FRACTURE GAPS
    DREBIN, RA
    MAGID, D
    ROBERTSON, DD
    FISHMAN, EK
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (03) : 487 - 489
  • [4] Tracheobronchial tree: Three-dimensional spiral CT with bronchoscopic perspective
    Ferretti, GR
    Vining, DJ
    Knoplioch, J
    Coulomb, M
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (05) : 777 - 781
  • [5] Spiral CT angiography for preoperative planning in patients with epigastric tumors: Comparison with arteriography
    Freund, M
    Wesner, F
    Reibe, F
    Emde, L
    Hutzelmann, A
    Heller, M
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (05) : 786 - 791
  • [6] FROLICH JJ, 1998, ROFO FORTSCHR RONTG, V169, P115
  • [7] TEMPORAL BONE - 3-DIMENSIONAL CT .1. NORMAL ANATOMY, TECHNIQUES, AND LIMITATIONS
    HOWARD, JD
    ELSTER, AD
    MAY, JS
    [J]. RADIOLOGY, 1990, 177 (02) : 421 - 425
  • [8] Jansen O, 1998, ROFO-FORTSCHR RONTG, V169, P175
  • [9] A COMPARISON OF CONVENTIONAL AND SPIRAL CT - AN EXPERIMENTAL-STUDY ON THE DETECTION OF SPHERICAL LESIONS
    KALENDER, WA
    POLACIN, A
    SUSS, C
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) : 167 - 176
  • [10] Cardiac multidetector-row CT:: Retrospectively ECG-gated spiral with optimized temporal and spatial resolution:: First clinical results.
    Kopp, AF
    Ohnesorge, B
    Flohr, T
    Georg, C
    Schröder, S
    Küttner, A
    Martensen, J
    Claussen, CD
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (05): : 429 - 435