Reliable and Robust Transmission and Storage Techniques for Medical Images with Patient Information

被引:6
作者
Nergui, Myagmarbayar [3 ]
Acharya, U. Sripati [3 ]
Rajendra, Acharya U. [1 ]
Yu, Wenwei [2 ]
机构
[1] Ngee Ann Polytech, Dept ECE, Singapore, Singapore
[2] Chiba Univ, Grad Sch Med Syst Engn, Chiba 2638522, Japan
[3] Natl Inst Technol Karnataka, Dept Elect & Commun, Surathkal, India
关键词
Digital watermarking; Reed-Solomon codes; Turbo codes; Advanced Encryption Standard (AES); Additive White Gaussian Noise (AWGN);
D O I
10.1007/s10916-009-9332-3
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
There is an increased emphasis on the use of digital techniques in all aspects of human life today. Broadcast radio and television, cellular phone services, consumer and entertainment electronics etc are increasingly using digital signal processing techniques to improve the quality of service. Transmission and storage of documentation and images pertaining to patient records cannot remain an exception to this global trend. Hence, patient records (text and image information) are increasingly stored and processed in digital form. Currently, text and image information, which constitute two separate pieces of data are handled as different files. Thus, there is a possibility of the text and message information, pertaining to different patients, being interchanged and thus mishandled. This can be avoided by merging text and image information in such a manner that the two can be separated without perceptible damage to information contained in either file. Digital watermarking techniques can be used to interleave patient information with medical images. In this work, we have employed digital watermarking along with strong cryptographic protocols and powerful error correcting codes. This reduces the probability of sensitive patient information falling into the wrong hands and ensures information integrity when it is conveyed over noisy channels.
引用
收藏
页码:1129 / 1139
页数:11
相关论文
共 25 条
[1]   Transmission and storage of medical images with patient information [J].
Acharya, R ;
Bhat, PS ;
Kumar, S ;
Min, LC .
COMPUTERS IN BIOLOGY AND MEDICINE, 2003, 33 (04) :303-310
[2]   Compact storage of medical images with patient information [J].
Acharya, UR ;
Anand, D ;
Bhat, PS ;
Niranjan, UC .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2001, 5 (04) :320-323
[3]  
[Anonymous], 2001, FEDERAL INFORM PROCE, V197
[4]  
BENEDETTO S, 1996, 42127 TDA
[5]  
BERROU C, 1993, IEEE INTERNATIONAL CONFERENCE ON COMMUNICATIONS 93 : TECHNICAL PROGRAM, CONFERENCE RECORD, VOLS 1-3, P1064, DOI 10.1109/ICC.1993.397441
[6]  
Blahut R.B., 2002, ALGEBRAIC CODES DATA
[7]  
Chung YY, 2003, ICCE: 2003 INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS, DIGEST OF TECHNICAL PAPERS, P214
[8]  
Daemen J, 1999, AES PROPOSAL RIJNDAE
[9]  
ELLIOTT M, 2006, DIGITAL IMAGE WATERM
[10]   Managing medical images and clinical information: InCor's experience [J].
Furuie, Sergio S. ;
Rebelo, Marina S. ;
Moreno, Ramon A. ;
Santos, Marcelo ;
Bertozzo, Nivaldo ;
Motta, Gustavo H. M. B. ;
Pires, Fabio A. ;
Gutierrez, Marco A. .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2007, 11 (01) :17-24