A comparison of direct laryngoscopy and jaw thrust to aid fibreoptic intubation

被引:27
作者
Stacey, MR [1 ]
Rassam, S [1 ]
Sivasankar, R [1 ]
Hall, JE [1 ]
Latto, IP [1 ]
机构
[1] Univ Wales Hosp, Dept Anaesthet & Intens Care Med, Cardiff CF14 4XW, S Glam, Wales
关键词
D O I
10.1111/j.1365-2044.2004.04119.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We compared two manoeuvres, jaw thrust and laryngoscopy, to open the airway during fibreoptic intubation in 50 patients after induction of anaesthesia in a crossover study. Patients were randomly allocated to receive either jaw thrust or conventional Macintosh laryngoscopy first. Airway clearance was assessed at both the soft palate and the epiglottis. Direct laryngoscopy provided significantly better airway clearance at the level of the soft palate than jaw thrust (44 (88%) vs 31 (62%), respectively; p = 0.002). At the level of the larynx, airway clearance was equally good in both groups (45 (90%) vs 46 (92%), respectively; p = 0.56). The times to view the larynx (median (interquartile range [range]) 4 (3-5 [2-35]) s vs 3 (3-4 [2-8]) s, respectively) and intubation time (20 (17-23 [11-83]) s vs 18 (15-20 [11-28]) s, respectively) were also similar.
引用
收藏
页码:445 / 448
页数:4
相关论文
共 20 条
[1]   Use of the McCoy laryngoscope or fingers to facilitate fibrescope-aided tracheal intubation [J].
Asai, T ;
Matsumoto, S ;
Shingu, K .
ANAESTHESIA, 1998, 53 (09) :903-905
[2]   Difficulty in advancing a tracheal tube over a fibreoptic bronchoscope: incidence, causes and solutions [J].
Asai, T ;
Shingu, K .
BRITISH JOURNAL OF ANAESTHESIA, 2004, 92 (06) :870-881
[3]  
BERMAN RA, 1977, ANESTH ANALG, V56, P866
[4]   AIRWAY PATENCY IN THE UNCONSCIOUS PATIENT [J].
BOIDIN, MP .
BRITISH JOURNAL OF ANAESTHESIA, 1985, 57 (03) :306-310
[5]   DIFFICULT TRACHEAL INTUBATION IN OBSTETRICS [J].
CORMACK, RS ;
LEHANE, J .
ANAESTHESIA, 1984, 39 (11) :1105-1111
[6]   Fibreoptic intubation in the anaesthetized patient [J].
Dennehy, KC ;
Dupuis, JY .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1996, 43 (02) :197-198
[7]   Manoeuvres used to clear the airway during fibreoptic intubation [J].
Durga, VK ;
Millns, JP ;
Smith, JE .
BRITISH JOURNAL OF ANAESTHESIA, 2001, 87 (02) :207-211
[8]   The left molar approach assisting fibreoptic intubation [J].
Farley, C ;
Bowler, I ;
Stacey, M .
ANAESTHESIA, 2002, 57 (10) :1031-1033
[9]   Comparison of the Williams Airway Intubator and Ovassapian Fibreoptic Intubating Airway for fibreoptic orotracheal intubation [J].
Greenland, KB ;
Lam, MC ;
Irwin, MG .
ANAESTHESIA, 2004, 59 (02) :173-176
[10]   Difficult Airway Society guidelines for management of the unanticipated difficult intubation [J].
Henderson, JJ ;
Popat, MT ;
Latto, IP ;
Pearce, AC .
ANAESTHESIA, 2004, 59 (07) :675-694