Head-to-head comparison of [68Ga]Ga-P16-093 and [68Ga]Ga-PSMA-617 in dynamic PET/CT evaluation of the same group of recurrent prostate cancer patients

被引:16
|
作者
Wang, Guochang [1 ]
Hong, Haiyan [2 ]
Zang, Jie [1 ]
Liu, Qingxing [1 ]
Jiang, Yuanyuan [1 ]
Fan, Xinrong [3 ]
Zhu, Zhaohui [1 ]
Zhu, Lin [2 ]
Kung, Hank F. [4 ]
机构
[1] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Peking Union Med Coll,Beijing Key Lab Mol Targete, Dept Nucl Med,State Key Lab Complex Severe & Rare, Beijing 100730, Peoples R China
[2] Beijing Normal Univ, Minist Educ, Coll Chem, Key Lab Radiopharmaceut, Beijing 100875, Peoples R China
[3] Chinese Acad Med Sci, Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Urol, Beijing 100730, Peoples R China
[4] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
基金
中国国家自然科学基金;
关键词
Ga-68]Ga-P16-093; Ga-68]Ga-PSMA-617; Dynamic PET/CT; Prostate cancer; MEMBRANE ANTIGEN-EXPRESSION; GA-68-LABELED PSMA LIGAND; GA-68-PSMA PET/CT; RADIATION-DOSIMETRY; DIAGNOSIS; BIODISTRIBUTION; APPROVAL; GALLIUM; CHELATE; EANM;
D O I
10.1007/s00259-021-05539-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose This study was prospectively designed to evaluate the early dynamic organ distribution and tumor detection capability of [Ga-68]Ga-P16-093, which was compared with [Ga-68]Ga-PSMA-617 in the same group of recurrent prostate cancer patients. Methods Twenty patients with recurrent prostate cancer were enrolled. In 2 consecutive days, each patient underwent a 60-min dynamic PET/CT scan after intravenous administration of 148-185 MBq (4-5 mCi) [Ga-68]Ga-P16-093 and [Ga-68]Ga-PSMA-617, respectively. Following a low-dose CT scan, serial dynamic PET scans were performed from head to proximal thigh at 9 time points (30 s/bed at 4, 7, 10, 13, and 16 min; 1 min/bed at 20, 30, and 45 min; and 2 min/bed at 60 min). Standardized uptake values were measured for semi-quantitative comparison. Results [Ga-68]Ga-P16-093 PET/CT revealed a significantly higher tumor uptake at 4 min (SUVmax 7.88 +/- 5.26 vs. 6.01 +/- 3.88, P < 0.001), less blood pool retention at 4 min (SUVmean 5.12 +/- 1.16 vs. 6.14 +/- 0.98, P < 0.001), and lower bladder accumulation at 60 min (SUVmean 31.33 +/- 27.47 vs. 48.74 +/- 34.01, P = 0.042) than [Ga-68]Ga-PSMA-617 scan. Significantly higher [Ga-68]Ga-P16-093 uptakes were also observed in the parotid gland, liver, spleen, and kidney. Besides, [Ga-68]Ga-P16-093 exhibited a better detectability of tumor than [Ga-68]Ga-PSMA-617 (366 vs. 321, P = 0.009). Conclusions [Ga-68]Ga-P16-093 showed advantages over [Ga-68]Ga-PSMA-617 with higher tumor uptakes, tumor-to-blood pool ratio and detection capability, less blood pool, and bladder accumulation in recurrent prostate cancer patients.
引用
收藏
页码:1052 / 1062
页数:11
相关论文
共 50 条
  • [31] Systemic therapy response evaluation in prostate carcinoma with [68Ga]Ga-PSMA-11 PET/CT
    Kucuker, Kadir Alper
    Yapar, Zeynep
    Guney, Isa Burak
    Paydas, Semra
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2022, 53 (01)
  • [32] [68Ga]Ga-PSMA-11 in prostate cancer: a comprehensive review
    Bois, Frederic
    Noirot, Camille
    Dietemann, Sebastien
    Mainta, Ismini C.
    Zilli, Thomas
    Garibotto, Valentina
    Walter, Martin A.
    AMERICAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 10 (06): : 349 - 374
  • [33] Systemic therapy response evaluation in prostate carcinoma with [68Ga]Ga-PSMA-11 PET/CT
    Kadir Alper Kucuker
    Zeynep Yapar
    Isa Burak Guney
    Semra Paydas
    Egyptian Journal of Radiology and Nuclear Medicine, 53
  • [34] Detection rate of PET/CT in patients with biochemical relapse of prostate cancer using [68Ga]PSMA I&T and comparison with published data of [68Ga]PSMA HBED-CC
    Berliner, Christoph
    Tienken, Milena
    Frenzel, Thorsten
    Kobayashi, Yuske
    Helberg, Annabelle
    Kirchner, Uve
    Klutmann, Susanne
    Beyersdorff, Dirk
    Budaeus, Lars
    Wester, Hans-Juergen
    Mester, Janos
    Bannas, Peter
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 (04) : 670 - 677
  • [35] Digital versus analogue PET in [68Ga]Ga-PSMA-11 PET/CT for recurrent prostate cancer: a matched-pair comparison
    Ian Alberts
    George Prenosil
    Christos Sachpekidis
    Thilo Weitzel
    Kuangyu Shi
    Axel Rominger
    Ali Afshar-Oromieh
    European Journal of Nuclear Medicine and Molecular Imaging, 2020, 47 : 614 - 623
  • [36] Superscan Appearance of 68Ga PSMA PET/CT in a Patient with Refractory Prostate Cancer
    Koc, Zehra Pinar
    Ozcan, Pinar Pelin
    Ercolak, Vehbi
    Reyhan, Mehmet
    MOLECULAR IMAGING AND RADIONUCLIDE THERAPY, 2022, 31 (01) : 60 - 62
  • [37] Diffuse Pulmonary Metastases From Prostate Cancer on 68Ga PSMA PET/CT
    Seniaray, Nikhil
    Verma, Ritu
    Belho, Ethel
    Malik, Dharmender
    Mahajan, Harsh
    CLINICAL NUCLEAR MEDICINE, 2019, 44 (11) : 898 - 900
  • [38] Cost-effectiveness of the implementation of [68Ga]Ga-PSMA-11 PET/CT at initial prostate cancer staging
    Esmée C. A. van der Sar
    Willem R. Keusters
    Ludwike W. M. van Kalmthout
    Arthur J. A. T. Braat
    Bart de Keizer
    Geert W. J. Frederix
    Anko Kooistra
    Jules Lavalaye
    Marnix G. E. H. Lam
    Harm H. E. van Melick
    Insights into Imaging, 13
  • [39] Cost-effectiveness of the implementation of [68Ga]Ga-PSMA-11 PET/CT at initial prostate cancer staging
    van der Sar, Esmee C. A.
    Keusters, Willem R.
    van Kalmthout, Ludwike W. M.
    Braat, Arthur J. A. T.
    de Keizer, Bart
    Frederix, Geert W. J.
    Kooistra, Anko
    Lavalaye, Jules
    Lam, Marnix G. E. H.
    van Melick, Harm H. E.
    INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [40] [18F]AlF-PSMA-11 PET in diagnosing prostate cancer: a head-to-head comparison with [68Ga]Ga-PSMA-11 PET and an exploration of dual-phase scanning
    Li, Xiao
    Yu, Mingming
    Yang, Jian
    Li, Danni
    Li, Rou
    Mao, Juanli
    Zuo, Changjing
    Liang, Zeying
    Li, Qiang
    Cheng, Chao
    EJNMMI REPORTS, 2024, 8 (01)