High-resolution x-ray guided three-dimensional diffuse optical tomography of joint tissues in hand osteoarthritis: Morphological and functional assessments

被引:17
|
作者
Yuan, Zhen [1 ]
Zhang, Qizhi [1 ]
Sobel, Eric S. [2 ]
Jiang, Huabei [1 ]
机构
[1] Univ Florida, Dept Biomed Engn, Gainesville, FL 32611 USA
[2] Univ Florida, Coll Med, Div Rheumatol, Gainesville, FL 32611 USA
基金
美国国家卫生研究院;
关键词
diffuse optical tomography; x-ray; multimodality imaging; finger joint; bone; FINGER JOINTS; ULTRASOUND; RECONSTRUCTION; SPECTROSCOPY; ALGORITHM; ARTHRITIS; PROSPECTS; CARTILAGE; DISEASE; LIGHT;
D O I
10.1118/1.3467755
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to investigate the potential use of multimodality functional imaging techniques to identify the quantitative optical findings that can be used to distinguish between osteoarthritic and normal finger joints. Methods: Between 2006 and 2009, the distal interphalangeal finger joints from 40 female subjects including 22 patients and 18 healthy controls were examined clinically and scanned by a hybrid imaging system. This system integrated x-ray tomosynthetic setup with a diffuse optical imaging system. Optical absorption and scattering images were recovered based on a regularization-based hybrid reconstruction algorithm. A receiver operating characteristic curve was used to calculate the statistical significance of specific optical features obtained from osteoarthritic and healthy joints groups. Results: The three-dimensional optical and x-ray images captured made it possible to quantify optical properties and joint space width of finger joints. Based on the recovered optical absorption and scattering parameters, the authors observed statistically significant differences between healthy and osteoarthritis finger joints. Conclusions: The statistical results revealed that sensitivity and specificity values up to 92% and 100%, respectively, can be achieved when optical properties of joint tissues were used as classifiers. This suggests that these optical imaging parameters are possible indicators for diagnosing osteoarthritis and monitoring its progression. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3467755]
引用
收藏
页码:4343 / 4354
页数:12
相关论文
共 16 条
  • [1] Tomographic x-ray guided three-dimensional diffuse optical imaging of osteoarthritis in the finger joints: A clinical study
    Yuan, Zhen
    Jiang, Huizhu
    Zhang, Qizhi
    Sobel, Eric S.
    Jiang, Huabei
    OPTICS IN BONE BIOLOGY AND DIAGNOSTICS, 2009, 7166
  • [2] X-ray guided three-dimensional diffuse optical tomography: In vivo study of osteoarthritis in the finger joints
    Zhang, Qizhi
    Yuan, Zhen
    Sobel, Eric
    Jiang, Huabei
    MULTIMODAL BIOMEDICAL IMAGING II, 2007, 6431
  • [3] Tomographic x-ray-guided three-dimensional diffuse optical tomography of osteoarthritis in the finger joints
    Yuan, Zhen
    Zhang, Qizhi
    Sobel, Eric S.
    Jiang, Huabei
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (04)
  • [4] Imaging osteoarthritis in the knee joints using x-ray guided diffuse optical tomography
    Zhang, Qizhi
    Yuan, Zhen
    Sobel, Eric S.
    Jiang, Huabei
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS VI, 2010, 7548
  • [5] High-resolution X-ray microtomography for three-dimensional visualization of human stem cell muscle homing
    Torrente, Y.
    Gavina, A.
    Belicchi, A.
    Fiori, F.
    Komlev, V.
    Bresolin, N.
    Rustichelli, F.
    FEBS LETTERS, 2006, 580 (24) : 5759 - 5764
  • [6] High resolution X-ray tomography - three-dimensional characterisation of cell-scaffold constructs for cartilage tissue engineering
    Zehbe, R.
    Schmitt, V. H.
    Kirkpatrick, C. J.
    Brochhausen, C.
    MATERIALS SCIENCE AND TECHNOLOGY, 2015, 31 (02) : 167 - 173
  • [7] Two- and three-dimensional high-resolution imaging of the human oviduct with optical coherence tomography
    Herrmann, JM
    Brezinski, ME
    Bouma, BE
    Boppart, SA
    Pitris, C
    Southern, JF
    Fujimoto, JG
    FERTILITY AND STERILITY, 1998, 70 (01) : 155 - 158
  • [8] High-resolution X-ray microtomography for three-dimensional imaging of cardiac progenitor cell homing in infarcted rat hearts
    Giuliani, Alessandra
    Frati, Caterina
    Rossini, Alessandra
    Komlev, Vladimir S.
    Lagrasta, Costanza
    Savi, Monia
    Cavalli, Stefano
    Gaetano, Carlo
    Quaini, Federico
    Manescu, Adrian
    Rustichelli, Franco
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2011, 5 (08) : E168 - E178
  • [9] High-speed data acquisition for three-dimensional x-ray and neutron computed tomography
    Davis, AW
    Claytor, TN
    Sheats, MJ
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 246 - 255
  • [10] Three-dimensional modelling of the middle-ear ossicular chain using a commercial high-resolution X-ray CT scanner
    Decraemer, WF
    Dirckx, JJJ
    Funnell, WRJ
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2003, 4 (02): : 250 - 263