Biomechanical implications of the fenestration structure after thoracic endovascular aortic repair

被引:20
作者
Qiao, Yonghui [1 ]
Mao, Le [2 ]
Zhu, Ting [2 ]
Fan, Jianren [1 ]
Luo, Kun [1 ]
机构
[1] Zhejiang Univ, State Key Lab Clean Energy Utilizat, 38 Zheda Rd, Hangzhou 310027, Peoples R China
[2] Fudan Univ, Zhongshan Hosp, Dept Vasc Surg, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Thoracic endovascular aortic repair; Left subclavian artery; In situ fenestration; Windkessel model; Fluid-structure interaction; Computational fluid dynamics; LEFT SUBCLAVIAN ARTERY; IN-SITU FENESTRATION; STENT-GRAFT; BLOOD-FLOW; SIMULATION; HEMODYNAMICS; ANEURYSM; UNSTEADY; DISEASE; IMPACT;
D O I
10.1016/j.jbiomech.2019.109478
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The inadequate landing zone during thoracic endovascular aortic repair (TEVAR) could be resolved by fenestration technology. The fenestration structure consists of a main endograft and a left subclavian artery (LSA) stent-graft. The purpose of this study is to assess the biomechanical implications of the protruding segment (PS) of the LSA stent-graft after TEVAR with in situ fenestration (ISF-TEVAR). The PS is characterized by the protruding length and centerline angle between the LSA and PS. An idealized three-dimensional geometric model of the human aorta was constructed as the reference benchmark. We designed nine postoperative aortic geometries with different protruding lengths (5, 10, 15?mm) and centerline angles (-20 degrees, 0 degrees, +20 degrees). The blood was assumed to be non-Newtonian and the three-element Windkessel model was applied to reproduce physiological pressure waveforms. The interaction between the blood and vessel wall was captured by a two-way fluid-structure method. We also considered the impact of the fenestration structure on the vessel wall. Long protruding length (15?mm) and the retrograde angle (+20 degrees) result in a markedly reduced LSA flow ratio (1.3%). There is a pressure difference between the inner and outer walls of the PS. The region around the PS is more prone to thrombosis. The flow stability and turbulence intensity of downstream blood of the PS gradually deteriorate. The largest deformed region moves from the aortic arch to the ascending aorta after ISF-TEVAR. The postoperative hemodynamics largely depends on the protruding length and angle of the LSA stent-graft. The configurations should be carefully controlled during ISF-TEVAR. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:9
相关论文
共 32 条
[1]   Aortic dissection simulation models for clinical support: fluid-structure interaction vs. rigid wall models [J].
Alimohammadi, Mona ;
Sherwood, Joseph M. ;
Karimpour, Morad ;
Agu, Obiekezie ;
Balabani, Stavroula ;
Diaz-Zuccarini, Vanessa .
BIOMEDICAL ENGINEERING ONLINE, 2015, 14
[2]   Development of a patient-specific simulation tool to analyse aortic dissections: Assessment of mixed patient-specific flow and pressure boundary conditions [J].
Alimohammadi, Mona ;
Agu, Obiekezie ;
Balabani, Stavroula ;
Diaz-Zuccarini, Vanessa .
MEDICAL ENGINEERING & PHYSICS, 2014, 36 (03) :275-284
[3]   Treatment of Complex Aneurysmal Disease with Fenestrated and Branched Stent Grafts [J].
Bicknell, C. D. ;
Cheshire, N. J. W. ;
Riga, C. V. ;
Bourke, P. ;
Wolfe, J. H. N. ;
Gibbs, R. G. J. ;
Jenkins, M. P. ;
Hamady, M. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2009, 37 (02) :175-181
[4]   Accuracy vs. computational time: Translating aortic simulations to the clinic [J].
Brown, Alistair G. ;
Shi, Yubing ;
Marzo, Alberto ;
Staicu, Cristina ;
Valverde, Isra ;
Beerbaum, Philipp ;
Lawford, Patricia V. ;
Hose, D. Rodney .
JOURNAL OF BIOMECHANICS, 2012, 45 (03) :516-523
[5]   Evaluation of Peak Wall Stress in an Ascending Thoracic Aortic Aneurysm Using FSI Simulations: Effects of Aortic Stiffness and Peripheral Resistance [J].
Campobasso, Rossella ;
Condemi, Francesca ;
Viallon, Magalie ;
Croisille, Pierre ;
Campisi, Salvatore ;
Avril, Stephane .
CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2018, 9 (04) :707-722
[6]   Endovascular Aortic Repair Versus Open Surgical Repair for Descending Thoracic Aortic Disease A Systematic Review and Meta-Analysis of Comparative Studies [J].
Cheng, Davy ;
Martin, Janet ;
Shennib, Hani ;
Dunning, Joel ;
Muneretto, Claudio ;
Schueler, Stephan ;
Von Segesser, Ludwig ;
Sergeant, Paul ;
Turina, Marko .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10) :986-1001
[7]   Fluid-structure interaction within realistic three-dimensional models of the aneurysmatic aorta as a guidance to assess the risk of rupture of the aneurysm [J].
Di Martino, ES ;
Guadagni, G ;
Fumero, A ;
Ballerini, G ;
Spirito, R ;
Biglioli, P ;
Redaelli, A .
MEDICAL ENGINEERING & PHYSICS, 2001, 23 (09) :647-655
[8]   A patient-specific follow up study of the impact of thoracic endovascular repair (TEVAR) on aortic anatomy and on post-operative hemodynamics. [J].
Gallo, Diego ;
Lefieux, Adrien ;
Morganti, Simone ;
Veneziani, Alessandro ;
Reali, Alessandro ;
Auricchio, Ferdinando ;
Conti, Michele ;
Morbiducci, Umberto .
COMPUTERS & FLUIDS, 2016, 141 :54-61
[9]   The influence of the non-Newtonian properties of blood on the flow in large arteries:: unsteady flow in a 90° curved tube [J].
Gijsen, FJH ;
Allanic, E ;
van de Vosse, FN ;
Janssen, JD .
JOURNAL OF BIOMECHANICS, 1999, 32 (07) :705-713
[10]   A Comprehensive Review of In Situ Fenestration of Aortic Endografts [J].
Glorion, M. ;
Coscas, R. ;
McWilliams, R. G. ;
Javerliat, I. ;
Goeau-Brissonniere, O. ;
Coggia, M. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2016, 52 (06) :787-800