Transition edge sensor-based detector: from X-ray to γ-ray

被引:0
作者
Zhang, Shuo [1 ]
Xia, Jing-Kai [1 ]
Sun, Tao [2 ]
Wu, Wen-Tao [2 ]
Wu, Bing-Jun [2 ]
Wang, Yong-Liang [2 ]
Cantor, Robin [3 ]
Han, Ke [4 ,5 ]
Zhou, Xiao-Peng [6 ]
Liu, Hao-Ran [7 ]
Fan, Fu-You [7 ]
Guo, Si-Ming [7 ]
Liang, Jun-Cheng [7 ]
Li, De-Hong [7 ]
Song, Yan-Ru [1 ]
Ju, Xu-Dong [1 ]
Fu, Qiang [1 ]
Liu, Zhi [1 ]
机构
[1] ShanghaiTech Univ, Ctr Transformat Sci, Shanghai 201210, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, Shanghai 200050, Peoples R China
[3] STAR Cryoelect, 25-A Bisbee Court, Santa Fe, NM 87508 USA
[4] Shanghai Jiao Tong Univ, Shanghai Lab Particle Phys & Cosmol, INPAC, Shanghai 200240, Peoples R China
[5] Shanghai Jiao Tong Univ, Dept Phys & Astron, Shanghai 200240, Peoples R China
[6] Beihang Univ, Sch Phys, Beijing 100191, Peoples R China
[7] Natl Inst Metrol, Div Ionizing Radiat, NIM, 18 Bei San Huan Dong Lu, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
Synchrotron radiation instrumentation; X-ray spectrometers; Cryogenic detectors; Transition edge sensor; SPECTROSCOPY; SPECTROMETER; CALORIMETER;
D O I
10.1007/s41365-022-01071-5
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A transition edge sensor (TES) is extremely sensitive to changes in temperature, and combined with a high-Z metal of a certain thickness, it can realize high-energy resolution measurements of particles such as X-rays. X-rays with energies below 10 keV have a weak penetrating ability, hence, only gold or bismuth of a few micrometers in thickness can guarantee a quantum efficiency higher than 70%. Therefore, the entire structure of the TES X-ray detector in this energy range can be realized using a microfabrication process. However, for X-rays or gamma-rays from 10 keV to 200 keV, submillimeter absorber layers are required, which cannot be realized using the microfabrication process. This paper first briefly introduces a set of TES X-ray detectors and their auxiliary systems, and then focuses on the introduction of the TES gamma-ray detector with an absorber based on a submillimeter lead-tin alloy sphere. The detector achieved a quantum efficiency above 70% near 100 keV and an energy resolution of approximately 161.5 eV at 59.5 keV.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Phonon-mediated superconducting transition-edge sensor X-ray detectors for use in astronomy
    Leman, SW
    Brink, PL
    Cabrera, B
    Castle, JP
    Martínez-Galarce, DS
    Stern, RA
    Tomada, A
    Young, BA
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XIII, 2004, 5165 : 565 - 575
  • [22] Fabrication and characterization of superconducting X-ray calorimeters with transition edge sensors
    Morooka, T
    Tanaka, K
    Nakayama, S
    Nagata, A
    Chinone, K
    Ukibe, M
    Hirayama, F
    Ohkubo, M
    Koyanagi, M
    Mizuki, T
    Hikosaka, T
    Kawabe, U
    Nemoto, T
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 751 - 754
  • [23] High temperature X-ray and γ-ray spectroscopy with a diamond detector
    Bodie, C. S.
    Lioliou, G.
    Whitaker, M. D. C.
    Barnett, A. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1058
  • [24] High-Resolution Kaonic-Atom X-ray Spectroscopy with Transition-Edge-Sensor Microcalorimeters
    S. Okada
    D. A. Bennett
    W. B. Doriese
    J. W. Fowler
    K. D. Irwin
    S. Ishimoto
    M. Sato
    D. R. Schmidt
    D. S. Swetz
    H. Tatsuno
    J. N. Ullom
    S. Yamada
    Journal of Low Temperature Physics, 2014, 176 : 1015 - 1021
  • [25] High-Resolution Kaonic-Atom X-ray Spectroscopy with Transition-Edge-Sensor Microcalorimeters
    Okada, S.
    Bennett, D. A.
    Doriese, W. B.
    Fowler, J. W.
    Irwin, K. D.
    Ishimoto, S.
    Sato, M.
    Schmidt, D. R.
    Swetz, D. S.
    Tatsuno, H.
    Ullom, J. N.
    Yamada, S.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2014, 176 (5-6) : 1015 - 1021
  • [26] Optimizing transition edge sensors for high-resolution X-ray spectroscopy
    Saab, Tarek
    Bandler, Simon R.
    Boyce, Kevin
    Chervenak, James A.
    Figueroa-Feliciano, Enectali
    Iyomoto, Naoko
    Kelley, Richard L.
    Kilbourne, Caroline A.
    Porter, Frederick S.
    Sadleir, John E.
    LOW TEMPERATURE PHYSICS, PTS A AND B, 2006, 850 : 1605 - 1608
  • [27] X-ray Spectroscopy of Muonic Atoms Isolated in Vacuum with Transition Edge Sensors
    Okada, S.
    Azuma, T.
    Bennett, D. A.
    Caradonna, P.
    Doriese, W. B.
    Durkin, M. S.
    Fowler, J. W.
    Gard, J. D.
    Hashimoto, T.
    Hayakawa, R.
    Hilton, G. C.
    Ichinohe, Y.
    Indelicato, P.
    Isobe, T.
    Kanda, S.
    Katsuragawa, M.
    Kawamura, N.
    Kino, Y.
    Miyake, Y.
    Morgan, K. M.
    Ninomiya, K.
    Noda, H.
    O'Neil, G. C.
    Okumura, T.
    Reintsema, C. D.
    Schmidt, D. R.
    Shimomura, K.
    Strasser, P.
    Swetz, D. S.
    Takahashi, T.
    Takeda, S.
    Takeshita, S.
    Tatsuno, H.
    Ueno, Y.
    Ullom, J. N.
    Watanabe, S.
    Yamada, S.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2020, 200 (5-6) : 445 - 451
  • [28] X-ray Spectroscopy of Muonic Atoms Isolated in Vacuum with Transition Edge Sensors
    S. Okada
    T. Azuma
    D. A. Bennett
    P. Caradonna
    W. B. Doriese
    M. S. Durkin
    J. W. Fowler
    J. D. Gard
    T. Hashimoto
    R. Hayakawa
    G. C. Hilton
    Y. Ichinohe
    P. Indelicato
    T. Isobe
    S. Kanda
    M. Katsuragawa
    N. Kawamura
    Y. Kino
    Y. Miyake
    K. M. Morgan
    K. Ninomiya
    H. Noda
    G. C. O’Neil
    T. Okumura
    C. D. Reintsema
    D. R. Schmidt
    K. Shimomura
    P. Strasser
    D. S. Swetz
    T. Takahashi
    S. Takeda
    S. Takeshita
    H. Tatsuno
    Y. Ueno
    J. N. Ullom
    S. Watanabe
    S. Yamada
    Journal of Low Temperature Physics, 2020, 200 : 445 - 451
  • [29] Non-linear effects in transition edge sensors for X-ray detection
    Bandler, SR
    Figueroa-Feliciano, E
    Iyomoto, N
    Kelley, RL
    Kilbourne, CA
    Murphy, KD
    Porter, FS
    Saab, T
    Sadleir, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 559 (02) : 817 - 819
  • [30] Development of Compact Dry 3He-4He Dilution Refrigerator for Transition Edge Sensor Microcalorimeter X-ray Detector Operation on Electron Microscopes
    Maehata, K.
    Iyomoto, N.
    Yamanaka, Y.
    Ito, T.
    Hara, T.
    Mitsuda, K.
    Yamasaki, N. Y.
    Tanaka, K.
    JOURNAL OF SUPERCONDUCTIVITY AND NOVEL MAGNETISM, 2015, 28 (03) : 1161 - 1165