Transition edge sensor-based detector: from X-ray to γ-ray

被引:0
作者
Zhang, Shuo [1 ]
Xia, Jing-Kai [1 ]
Sun, Tao [2 ]
Wu, Wen-Tao [2 ]
Wu, Bing-Jun [2 ]
Wang, Yong-Liang [2 ]
Cantor, Robin [3 ]
Han, Ke [4 ,5 ]
Zhou, Xiao-Peng [6 ]
Liu, Hao-Ran [7 ]
Fan, Fu-You [7 ]
Guo, Si-Ming [7 ]
Liang, Jun-Cheng [7 ]
Li, De-Hong [7 ]
Song, Yan-Ru [1 ]
Ju, Xu-Dong [1 ]
Fu, Qiang [1 ]
Liu, Zhi [1 ]
机构
[1] ShanghaiTech Univ, Ctr Transformat Sci, Shanghai 201210, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, Shanghai 200050, Peoples R China
[3] STAR Cryoelect, 25-A Bisbee Court, Santa Fe, NM 87508 USA
[4] Shanghai Jiao Tong Univ, Shanghai Lab Particle Phys & Cosmol, INPAC, Shanghai 200240, Peoples R China
[5] Shanghai Jiao Tong Univ, Dept Phys & Astron, Shanghai 200240, Peoples R China
[6] Beihang Univ, Sch Phys, Beijing 100191, Peoples R China
[7] Natl Inst Metrol, Div Ionizing Radiat, NIM, 18 Bei San Huan Dong Lu, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
Synchrotron radiation instrumentation; X-ray spectrometers; Cryogenic detectors; Transition edge sensor; SPECTROSCOPY; SPECTROMETER; CALORIMETER;
D O I
10.1007/s41365-022-01071-5
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A transition edge sensor (TES) is extremely sensitive to changes in temperature, and combined with a high-Z metal of a certain thickness, it can realize high-energy resolution measurements of particles such as X-rays. X-rays with energies below 10 keV have a weak penetrating ability, hence, only gold or bismuth of a few micrometers in thickness can guarantee a quantum efficiency higher than 70%. Therefore, the entire structure of the TES X-ray detector in this energy range can be realized using a microfabrication process. However, for X-rays or gamma-rays from 10 keV to 200 keV, submillimeter absorber layers are required, which cannot be realized using the microfabrication process. This paper first briefly introduces a set of TES X-ray detectors and their auxiliary systems, and then focuses on the introduction of the TES gamma-ray detector with an absorber based on a submillimeter lead-tin alloy sphere. The detector achieved a quantum efficiency above 70% near 100 keV and an energy resolution of approximately 161.5 eV at 59.5 keV.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Quantitative analysis with the transition edge sensor microcalorimeter X-ray detector
    Jach, Terrence
    Ritchie, Nicholas
    Ullom, Joel
    Beall, James A.
    POWDER DIFFRACTION, 2007, 22 (02) : 138 - 141
  • [2] Phonon-Mediated Distributed Transition-Edge-Sensor X-Ray Detector with Deep Trenches
    Steven W. Leman
    Paul L. Brink
    Blas Cabrera
    Astrid Tomada
    Betty Young
    Dennis S. Martínez-Galarce
    Journal of Low Temperature Physics, 2008, 151 : 40 - 45
  • [3] Transition edge sensor-based detector: from X-ray to γ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\gamma$$\end{document}-ray
    Shuo Zhang
    Jing-Kai Xia
    Tao Sun
    Wen-Tao Wu
    Bing-Jun Wu
    Yong-Liang Wang
    Robin Cantor
    Ke Han
    Xiao-Peng Zhou
    Hao-Ran Liu
    Fu-You Fan
    Si-Ming Guo
    Jun-Cheng Liang
    De-Hong Li
    Yan-Ru Song
    Xu-Dong Ju
    Qiang Fu
    Zhi Liu
    Nuclear Science and Techniques, 2022, 33 (7)
  • [4] Phonon-mediated distributed transition-edge-sensor X-ray detector with deep trenches
    Leman, Steven W.
    Brink, Paul L.
    Cabrera, Blas
    Tomada, Astrid
    Young, Betty
    Martinez-Galarce, Dennis S.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2008, 151 (1-2) : 40 - 45
  • [5] Fabrication of transition edge sensor X-ray microcalorimeters for constellation-X
    Chervenak, JA
    Finkbeiner, FM
    Stevenson, TR
    Talley, DJ
    Brekosky, RP
    Bandler, SR
    Figueroa-Feliciano, E
    Lindeman, MA
    Kelley, RL
    Saab, T
    Stahle, CK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3) : 460 - 462
  • [6] First results from Mo/Au transition-edge sensor X-ray calorimeters
    Stahle, CK
    Finkbeiner, FM
    Boyce, KR
    Chen, T
    Feliciano, EF
    Gygax, JD
    Kelley, RL
    Li, M
    Mattson, BJ
    Mott, DB
    Porter, FS
    Stahle, CM
    Szymkowiak, AE
    Tralshawala, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2) : 224 - 227
  • [7] Development of hard X-ray and gamma-ray spectrometer using superconducting transition edge sensor
    Hatakeyama, Shuichi
    Ohno, Masashi
    Damayanthi, R. M. Thushara
    Takahashi, Hiroyuki
    Kuno, Yusuke
    Iyomoto, Naoko
    Maehata, Keisuke
    Otani, Chiko
    Usui, Toshihide
    Onishi, Takashi
    Obayashi, Hiroshi
    Takasaki, Koji
    RADIATION MEASUREMENTS, 2013, 55 : 83 - 86
  • [8] Development of Hard X-Ray and Gamma-Ray Spectrometer Using Superconducting Transition Edge Sensor
    Hatakeyama, S.
    Ohno, M.
    Damayanthi, R. M. T.
    Takahashi, H.
    Kuno, Y.
    Maehata, K.
    Otani, C.
    Takasaki, K.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2013, 23 (03)
  • [9] Transition-edge microcalorimeters for X-ray space applications
    Luukanen, A
    Sipilä, H
    Kinnunen, K
    Nuottajärvi, A
    Pekola, J
    PHYSICA B, 2000, 284 (284): : 2133 - 2134
  • [10] Transition edge X-ray sensors for industrial applications
    Tanaka, K
    Morooka, T
    Fujimoto, R
    Ishisaki, Y
    Takei, Y
    Morita, U
    Iyomoto, N
    Oshima, T
    Nakayama, S
    Yamasaki, N
    Koyanagi, M
    Mitsuda, K
    Ohashi, T
    Chinone, K
    PHYSICA B-CONDENSED MATTER, 2003, 329 : 1619 - 1620