Analysis-oriented model for FRP tube-confined concrete: 3D interpretation of biaxial tube behaviour

被引:14
作者
Li, Zhiyuan [1 ]
Feng, Peng [1 ]
Yang, Jia-Qi [2 ]
机构
[1] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
[2] China Univ Min & Technol Beijing, Sch Mech & Civil Engn, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
Filament-wound FRP tube; Biaxial behaviour; Analysis-oriented model; Confined concrete; Concrete-filled FRP tube; AXIAL COMPRESSIVE BEHAVIOR; STRESS-STRAIN MODEL; FIBER ORIENTATION; COMPOSITE TUBES; TUBULAR COLUMNS; FAILURE; DEFORMATION; STRENGTH;
D O I
10.1016/j.engstruct.2022.114987
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Filament-wound fibre-reinforced polymer (FRP) tubes are an emerging FRP product employed in various FRP-concrete composite structures, such as concrete-filled FRP tubes (CFFTs). Due to the fibre orientations in the tube wall, the filament-wound FRP tube exhibits biaxial behaviour under simultaneous axial compression and hoop expansion, causing relaxation of the confining stress. Therefore, the conventional hoop tension test may result in overestimation of the confining stiffness. In this paper, the biaxial behaviour of FRP tubes is theoreti-cally investigated using classical laminate theory in conjunction with an analysis-oriented model for FRP-confined concrete. The geometrical meaning of the biaxial tube behaviour is interpreted intuitively using the 3D geometrical approach previously proposed by the authors. For the convenience of analysis and design, this paper proposes a simplified approach to rectify the confining stiffness that considers both elastic and nonlinear biaxial effects. The predicted results show good agreement with the collected test data.
引用
收藏
页数:9
相关论文
共 43 条
[1]  
[Anonymous], 2005, GB/T5350-2005
[2]  
[Anonymous], 2012, D229012 ASTM
[3]   The rate-dependent behaviour of +/-55 degrees filament-wound glass-fibre epoxy tubes under biaxial loading [J].
Carroll, M ;
Ellyin, F ;
Kujawski, D ;
Chiu, AS .
COMPOSITES SCIENCE AND TECHNOLOGY, 1995, 55 (04) :391-403
[4]   FRP rupture strains in the split-disk test [J].
Chen, J. F. ;
Li, S. Q. ;
Bisby, L. A. ;
Ai, J. .
COMPOSITES PART B-ENGINEERING, 2011, 42 (04) :962-972
[5]   Load-Strain Model for Steel-Concrete-FRP-Concrete Columns in Axial Compression [J].
Cheng, Shi ;
Feng, Peng ;
Bai, Yu ;
Ye, Lie Ping .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2016, 20 (05)
[6]  
Dang Z, 2022, COMPOS STRUCT, V300
[7]   Axial compressive behavior of engineered cementitious composite confined by fiber-reinforced polymer [J].
Dang, Zheng ;
Feng, Peng ;
Yang, Jia-Qi ;
Zhang, Qian .
COMPOSITE STRUCTURES, 2020, 243
[8]  
Feng P, 2021, INT C FIBRE REINFORC, P37
[9]  
Feng P, 2011, Application of fiber reinforced polymer in construction: experiment, theory and methodology
[10]   Novel joint for pultruded FRP beams and concrete-filled FRP columns: Conceptual and experimental investigations [J].
Feng, Peng ;
Li, Zhiyuan ;
Wang, Jie ;
Liu, TianQiao .
COMPOSITE STRUCTURES, 2022, 287