Comparison of plan quality provided by intensity-modulated arc therapy and helical tomotherapy

被引:79
作者
Cao, Daliang
Holmes, Timothy W.
Afghan, Muhammad K. N.
Shepard, David M.
机构
[1] Swedish Cancer Inst, Seattle, WA 98104 USA
[2] St Agnes Hosp, Dept Radiat Oncol, Baltimore, MD USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2007年 / 69卷 / 01期
基金
美国国家科学基金会;
关键词
intensity-modulated arc therapy; IMAT; tomotherapy; intensity-modulated radiotherapy; IMRT; arc sequencing inverse planning;
D O I
10.1016/j.ijrobp.2007.04.073
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Intensity-modulated arc therapy (IMAT) is an arc-based approach to intensity-modulated radiotherapy(IMRT) that can be delivered on a conventional linear accelerator using a conventional multileaf collimator. In a previous work, we demonstrated that our arc-sequencing algorithm can produce highly conformal IMAT plans. Through plan comparisons, we explored the ability of IMAT to serve as an alternative to helical tomotherapy. Methods and Materials: The IMAT plans were created for 10 patients previously treated with helical tomotherapy. Treatment plan comp. sons, according to the target dose coverage and critical structure sparing, were performed to determine whether similar plan quality could be achieved using IMAT. Results: In 8 of 10 patient cases,, IMAT was able to provide plan quality comparable to that of helical tomotherapy. in 2 of these 8 cases, the use of non-axial coplanar or non-coplanar arcs in IMAT planning led to significant improvements in normal tissue sparing. The remaining 2 cases posed particular dosimetric challenges. In 1 case, the target was immediately adjacent to a spinal cord that had received previous irradiation. The second case involved multiple target volumes and multiple prescription levels. Both IMAT and tornotherapy were able to produce clinically acceptable plans. Tomotherapy, however, provided a more uniform target dose and improved critical structure sparing. Conclusions: For most cases, IMAT can provide plan qualities comparable to that of helical tomotherapy. For some intracranial tumors, IMAT's ability to deliver non-coplanar arcs led to significant dosimetric improvements. Helical tomotherapy, however, can provide improved dosimetric results in the most complex cases. (c) 2007 Elsevier Inc.
引用
收藏
页码:240 / 250
页数:11
相关论文
共 15 条
  • [1] Continuous intensity map optimization (CIMO): A novel approach to leaf sequencing in step and shoot IMRT
    Cao, DL
    Earl, MA
    Luan, S
    Shepard, DM
    [J]. MEDICAL PHYSICS, 2006, 33 (04) : 859 - 867
  • [2] Intensity modulated arc therapy (IMAT) with centrally blocked rotational fields
    Cotrutz, C
    Kappas, C
    Webb, S
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08) : 2185 - 2206
  • [3] Clinical implementation of intensity-modulated arc therapy (IMAT) for rectal cancer
    Duthoy, W
    De Gersem, W
    Vergote, K
    Boterberg, T
    Derie, C
    Smeets, P
    De Wagter, C
    De Neve, W
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (03): : 794 - 806
  • [4] Inverse planning for intensity-modulated arc therapy using direct aperture optimization
    Earl, MA
    Shepard, DM
    Naqvi, S
    Li, XA
    Yu, CX
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (08) : 1075 - 1089
  • [5] HOLMES TW, 2006, ENCY MED DEVICES INS
  • [6] Optimized intensity-modulated arc therapy for prostate cancer treatment
    Ma, LJ
    Yu, CX
    Earl, M
    Holmes, T
    Sarfaraz, M
    Li, XA
    Shepard, D
    Amin, P
    DiBiase, S
    Suntharalingam, M
    Mansfield, C
    [J]. INTERNATIONAL JOURNAL OF CANCER, 2001, 96 (06) : 379 - 384
  • [7] Tomotherapy
    Mackie, TR
    Balog, J
    Ruchala, K
    Shepard, D
    Aldridge, S
    Fitchard, E
    Reckwerdt, P
    Olivera, G
    McNutt, T
    Mehta, M
    [J]. SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (01) : 108 - 117
  • [8] TOMOTHERAPY - A NEW CONCEPT FOR THE DELIVERY OF DYNAMIC CONFORMAL RADIOTHERAPY
    MACKIE, TR
    HOLMES, T
    SWERDLOFF, S
    RECKWERDT, P
    DEASY, JO
    YANG, J
    PALIWAL, B
    KINSELLA, T
    [J]. MEDICAL PHYSICS, 1993, 20 (06) : 1709 - 1719
  • [9] Leaf position error during conformal dynamic arc and intensity modulated arc treatments
    Ramsey, CR
    Spencer, KM
    Alhakeem, R
    Oliver, AL
    [J]. MEDICAL PHYSICS, 2001, 28 (01) : 67 - 72
  • [10] An arc-sequencing algorithm for intensity modulated arc therapy
    Shepard, D. M.
    Cao, D.
    Afghan, M. K. N.
    Earl, M. A.
    [J]. MEDICAL PHYSICS, 2007, 34 (02) : 464 - 470