An optimized Monte Carlo (PENELOPE) code for the characterization of gel-layer detectors in radiotherapy

被引:8
作者
Castellano, G. [1 ]
Brusa, D.
Carrara, M.
Gambarini, G.
Valente, M.
机构
[1] Natl Univ Cordoba, FaMAF, Cordoba, Argentina
[2] Consejo Nacl Invest Cient & Tecn, RA-1033 Buenos Aires, DF, Argentina
[3] Univ Milan, Dept Phys, INFN, I-20122 Milan, Italy
关键词
Monte Carlo simulation; external radiotherapy; Fricke gel dosimetry;
D O I
10.1016/j.nima.2007.05.215
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Monte Carlo (MC) simulation of radiation transport is considered to be one of the most accurate methods of radiation therapy dose calculation. A basic requirement for MC treatment planning is a detailed knowledge of the characteristics of radiation beam generated from medical linear accelerators (LINACs). One of the most important input parameters is the photon fluence of the beam, usually not determinable experimentally. Thus, an MC simulation code based on the PENELOPE package was developed in order to survey the influence of the incident spectrum on the in-phantom dose distributions. Different spectra for the incident photon fluence, have been considered in order to establish the most adequate one. The resulting planned dose distributions have been compared with those determined experimentally with ionization chamber measurements and gel dosimeter layers analyzed with optical technique. The specific gel composition has been implemented in the MC simulation code. Comparisons between experimental measurements, approximated simulations (water) and specific simulations (gel composition) have been performed. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:502 / 505
页数:4
相关论文
共 7 条
  • [1] Bero M. A., 2000, Journal of Radiological Protection, V20, P287, DOI 10.1088/0952-4746/20/3/303
  • [2] CUNNINGHAM J, 1982, PROGR MED RAD PHYS, V1
  • [3] Gambarini G., 2006, Journal of Physics: Conference Series, V41, P466, DOI 10.1088/1742-6596/41/1/052
  • [4] Study of light transmittance from layers of Fricke-xylenol-orange-gel dosimeters
    Gambarini, G
    Birattari, C
    Mariani, M
    Marchesini, R
    Pirola, L
    Prestini, P
    Sella, M
    Tomatis, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 321 - 324
  • [5] International Commission on Radiation Units and Measurements, 1976, International Commission on Radiation Units and Measurements ICRU Report 24
  • [6] Superposition dose calculation incorporating Monte Carlo generated electron track kernels
    Keall, PJ
    Hoban, PW
    [J]. MEDICAL PHYSICS, 1996, 23 (04) : 479 - 485
  • [7] Salvat F., 2003, PENELOPE CODE SYSTEM, DOI DOI 10.1787/4E3F14DB-EN