Tensile resistances of bolted circular flange connections

被引:30
|
作者
Couchaux, Mael [1 ]
Hjiaj, Mohammed [1 ]
Ryan, Ivor [2 ]
Bureau, Alain [2 ]
机构
[1] INSA Rennes UEB, Struct Engn Res Grp LGCGM, 20 Ave Buttes de Coesmes,CS 70839, F-35708 Rennes 7, France
[2] Espace Technol, Ctr Tech Ind Construct Metall, LOrme des Merisiers, F-91190 Immeuble Apollo, St Aubin, France
关键词
JOINT; FORCE;
D O I
10.1016/j.engstruct.2018.04.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A closed form solution for the ultimate tensile resistance of a bolted flange joint is derived considering yield line failure mechanisms developed by Igarashi et al. The position of the prying force is determined based on formulations previously developed by the authors. Under various simplified assumptions and approximations, a design approach similar to that of the Eurocode 3 for T-stubs is proposed. To validate this approach, experimental tests have been performed on six connections of circular hollow sections made of bolted ring flange. A finite element model considering the elastoplastic behaviour of steel and contact conditions has been developed and the results showed a good agreement with experimental results. Based on the FEM model, a parametric study shows that the proposed analytical model is valid for a wide range of connections.
引用
收藏
页码:817 / 841
页数:25
相关论文
共 50 条
  • [21] Fracture strength of welded flange-bolted web connections
    Job, CB
    Chen, WF
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1999, 125 (05): : 565 - 571
  • [22] BLOW-OUT SAFETY OF GASKETS FOR BOLTED FLANGE CONNECTIONS
    Roos, Eberhard
    Bartonicek, Jaroslav
    Kockelmann, Hans
    Hahn, Rolf
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, VOL 2, 2009, : 139 - 152
  • [23] Fracture strength of welded flange-bolted web connections
    Joh, Changbin
    Chen, Wai-Fah
    Journal of structural engineering New York, N.Y., 1999, 125 (05): : 565 - 572
  • [24] Fire Response of Steel Beams With Bolted Flange Plate Connections
    Marziyeh Ebrahimzadeh
    Abbas Rezaeian
    Fire Technology, 2022, 58 : 479 - 501
  • [25] Experimental analysis of passive intermodulation at waveguide flange bolted connections
    Vicente, Carlos
    Wolk, Dieter
    Hartnagel, Hans L.
    Gimeno, Benito
    Boria, Vicente E.
    Raboso, David
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2007, 55 (05) : 1018 - 1028
  • [26] Stress Analysis of Bolted Flange Joints with Different Shell Connections
    Choulaei, Mohammad
    Bouzid, Abdel-Hakim
    PROCEEDINGS OF ASME 2021 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE2021), VOL 12, 2021,
  • [27] Bolted CHS Flange-Plate Connections under Bending
    Fidalgo, Augusto
    Packer, Jeffrey A.
    JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (06)
  • [28] DESIGN OF FLOATING TYPE BOLTED FLANGE CONNECTIONS WITH GRP FLANGES
    Roos, Eberhard
    Kockelmann, Hans
    Kurz, Hariolf
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, VOL 2, 2009, : 53 - 59
  • [29] Fire Response of Steel Beams With Bolted Flange Plate Connections
    Ebrahimzadeh, Marziyeh
    Rezaeian, Abbas
    FIRE TECHNOLOGY, 2022, 58 (01) : 479 - 501
  • [30] Nonlinear effects of bolted flange connections in aeroengine casing assemblies
    Mir-Haidari, Seyed-Ehsan
    Behdinan, Kamran
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2022, 166