Silicon solid-state detectors for monitoring high-energy accelerator mixed field radiation environments

被引:4
|
作者
Bilko, Kacper [1 ]
Alia, Ruben Garcia [1 ]
Barbero, Mario Sacristan
Prelipcean, Daniel [1 ]
Cazzaniga, Carlo
Coronetti, Andrea [1 ,2 ]
Martin-Holgado, Pedro [4 ]
Morilla Garcia, Yolanda [4 ]
Lerner, Giuseppe [1 ]
Hajdas, Wojciech [3 ]
机构
[1] CERN, CH-1211 Geneva 23, Switzerland
[2] Univ Jyvaskyla, Dept Phys, Jyvaskyla 40014, Finland
[3] PSI, Forsch Str 111, CH-5232 Villigen, Switzerland
[4] Univ Seville, CSIC, CNA, Seville 41092, Spain
关键词
LHC;
D O I
10.1109/RADECS53308.2021.9954498
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper investigates an application of the 1000 mu m-thick silicon solid-state detector for monitoring of a mixed-field radiation environment, in particular an accelerator environment. The calibrations of the detector against both an alpha source and high-energy protons are presented. The protons measurements are benchmarked against the FLUKA Monte Carlo simulations. As the detector might be deployed in a future RadMON version, a simulated accelerator use case is presented, highlighting the enhanced sensitivity (by 3-4 orders of magnitude) with respect to SRAM-based solutions, in case of High Energy Hadron (HEH) fluence monitoring.
引用
收藏
页码:179 / 183
页数:5
相关论文