Transcatheter aortic valve implantation in patients with bicuspid aortic valve: a series of cases

被引:9
作者
Kosek, Mikolaj [1 ]
Witkowski, Adam [1 ]
Dabrowski, Maciej [1 ]
Jastrzebski, Jan [1 ]
Michalowska, Ilona [2 ]
Chmielak, Zbigniew [1 ]
Demkow, Marcin [3 ]
Ksiezycka-Majczynska, Ewa [1 ]
Michalek, Piotr [4 ]
Szymanski, Piotr [5 ]
Hryniewiecki, Tomasz [5 ]
Stepinska, Janina [6 ]
Sitkowska-Rysiak, Ewa [7 ]
Ruzyllo, Witold [3 ]
机构
[1] Inst Cardiol, Dept Intervent Cardiol & Angiol, PL-04628 Warsaw, Poland
[2] Inst Cardiol, Dept Radiol, Warsaw, Poland
[3] Inst Cardiol, Dept Coronary Artery Dis & Struct Heart Dis, Warsaw, Poland
[4] Inst Cardiol, Dept Early Diag, Warsaw, Poland
[5] Inst Cardiol, Dept Acquired Cardiac Defects, Warsaw, Poland
[6] Inst Cardiol, Intens Cardiac Therapy Clin, Warsaw, Poland
[7] Inst Cardiol, Dept Anaesthesiol, Warsaw, Poland
关键词
TAVI; aortic valve stenosis; bicuspid aortic valve; elliptic distortion; safety; HIGH-RISK PATIENTS; STENOSIS; PROSTHESIS; OUTCOMES; REPLACEMENT; STENT; TREAT;
D O I
10.5603/KP.a2015.0068
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Bicuspid aortic valve (BAV) has been considered a relative contraindication for transcatheter aortic valve implantation (TAVI). Due to more oval shape of the BAV annulus compared to tricuspid aortic valve, the procedure has been discouraged because of an increased risk of stent assembly displacement, uneven expansion, post-procedure paravalvular leakage, stent valve distortion, or other malfunction after implantation. For the same reasons patients with BAV have been excluded from the majority of clinical TAVI trials. Aim: To evaluate the efficacy and safety of TAVI in patients with BAV stenosis. Methods: We analysed a group of 104 patients admitted to our institution for TAVI between January 2009 and May 2012. During pre-procedure evaluation, transthoracic and transoesophageal (TEE) echocardiography as well as angio-computed tomography (CT) scan were performed to assess aortic valve anatomy and morphology. Appropriate measurements and detailed analyses of imaging data have been accomplished to select optimal access site, prosthesis size as well as to plan the procedure. BAVs were recorded in seven patients (6.7%; mean age 77.7 years). These patients presented with severe symptomatic aortic valve stenosis with a mean aortic valve area of 0.55 cm(2) (0.46-0.7 cm(2)) as measured in TEE. All of the patients had been disqualified from surgical valve replacement due to high surgical risk with a mean logistic Euroscore of 19.9%. All of them successfully underwent TAVI using CoreValve (n = 5) or Sapien (n = 2) valves. Follow-up was completed at 30 days, and six and 12 months after the procedure. Results: During follow-up one patient developed an elliptic distortion of the aortic prosthesis in CT, although it did not result in significant malfunctioning of the implant. One patient died of infective endocarditis 30 days after the procedure. Survivors at 30-day follow-up had mild to moderate aortic insufficiency, and it did not deteriorate after six months. At one year follow-up six out of seven patients remained alive. They achieved significant functional improvement by New York Heart Association class compared to baseline. Conclusions: TAVI may constitute an alternative treatment option for high-risk patients with BAV, resulting in a low periprocedural mortality rate, and good 30-day, six-month, and one-year outcomes.
引用
收藏
页码:627 / 636
页数:10
相关论文
共 27 条
[1]  
CAMPBELL M, 1968, BRIT HEART J, V30, P606
[2]   Implications of a congenitally abnormal valve: a study of 1025 consecutively excised aortic valves [J].
Collins, M. J. ;
Butany, J. ;
Borger, M. A. ;
Strauss, B. H. ;
David, T. E. .
JOURNAL OF CLINICAL PATHOLOGY, 2008, 61 (04) :530-536
[3]  
Delgado Victoria, 2009, Circ Cardiovasc Imaging, V2, pe12, DOI 10.1161/CIRCIMAGING.108.809434
[4]   Successful Transapical Aortic Valve Implantation in a Congenital Bicuspid Aortic Valve [J].
Ferrari, Enrico ;
Locca, Didier ;
Sulzer, Christopher ;
Marcucci, Carlo ;
Rizzo, Elena ;
Tozzi, Piergiorgio ;
von Segesser, Ludwig K. .
ANNALS OF THORACIC SURGERY, 2010, 90 (02) :630-632
[5]   Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease - The Siegburg First-in-Man Study [J].
Grube, Eberhard ;
Laborde, Jean C. ;
Gerckens, Ulrich ;
Felderhoff, Thomas ;
Sauren, Barthel ;
Buellesfeld, Lutz ;
Mueller, Ralf ;
Menichelli, Maurizio ;
Schmidt, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Stone, Gregg W. .
CIRCULATION, 2006, 114 (15) :1616-1624
[6]   Deformation Dynamics and Mechanical Properties of the Aortic Annulus by 4-Dimensional Computed Tomography [J].
Hamdan, Ashraf ;
Guetta, Victor ;
Konen, Eli ;
Goitein, Orly ;
Segev, Amit ;
Raanani, Ehud ;
Spiegelstein, Dan ;
Hay, Ilan ;
Di Segni, Elio ;
Eldar, Michael ;
Schwammenthal, Ehud .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (02) :119-127
[7]   Transcatheter Aortic Valve Implantation for Patients With Severe Bicuspid Aortic Valve Stenosis [J].
Hayashida, Kentaro ;
Bouvier, Erik ;
Lefevre, Thierry ;
Chevalier, Bernard ;
Hovasse, Thomas ;
Romano, Mauro ;
Garot, Philippe ;
Watanabe, Yusuke ;
Farge, Arnaud ;
Donzeau-Gouge, Patrick ;
Cormier, Bertrand ;
Morice, Marie-Claude .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (03) :284-291
[8]   Feasibility and Outcomes of Transcatheter Aortic Valve Implantation in High-Risk Patients With Stenotic Bicuspid Aortic Valves [J].
Himbert, Dominique ;
Pontnau, Florence ;
Messika-Zeitoun, David ;
Descoutures, Fleur ;
Detaint, Delphine ;
Cueff, Caroline ;
Sordi, Martina ;
Laissy, Jean-Pierre ;
Alkhoder, Soleiman ;
Brochet, Eric ;
Iung, Bernard ;
Depoix, Jean-Pol ;
Nataf, Patrick ;
Vahanian, Alec .
AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (06) :877-883
[9]   Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document [J].
Kappetein, A. Pieter ;
Head, Stuart J. ;
Genereux, Philippe ;
Piazza, Nicolo ;
van Mieghem, Nicolas M. ;
Blackstone, Eugene H. ;
Brott, Thomas G. ;
Cohen, David J. ;
Cutlip, Donald E. ;
van Es, Gerrit-Anne ;
Hahn, Rebecca T. ;
Kirtane, Ajay J. ;
Krucoff, Mitchell W. ;
Kodali, Susheel ;
Mack, Michael J. ;
Mehran, Roxana ;
Rodes-Cabau, Josep ;
Vranckx, Pascal ;
Webb, John G. ;
Windecker, Stephan ;
Serruys, Patrick W. ;
Leon, Martin B. .
EUROPEAN HEART JOURNAL, 2012, 33 (19) :2403-+
[10]   Direct transcatheter aortic valve implantation - one-year outcome of a case control study [J].
Kochman, Janusz ;
Koltowski, Lukasz ;
Huczek, Zenon ;
Scislo, Piotr ;
Bakon, Leopold ;
Wilimski, Radoslaw ;
Rymuza, Bartosz ;
Opolski, Grzegorz .
POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2014, 10 (04) :250-257