Application of structural analysis to the mechanical behaviour of the cornea

被引:174
作者
Anderson, K [1 ]
El-Sheikh, A [1 ]
Newson, T [1 ]
机构
[1] Univ Dundee, Dept Civil Engn, Dundee DD1 4HN, Scotland
关键词
structural analysis; corneal biomechanics; mathematical analysis; numerical modelling;
D O I
10.1098/rsif.2004.0002
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Structural engineering analysis tools have been used to improve the understanding of the biomechanical behaviour of the cornea. The research is a multi-disciplinary collaboration between structural engineers, mathematical and numerical analysts, ophthalmologists and clinicians. Mathematical shell analysis and nonlinear finite-element modelling have been used in conjunction with laboratory experiments to study the behaviour of the cornea under different loading states and to provide improved predictions of the mechanical response to disease and injury. The initial study involved laboratory tests and mathematical back analysis to determine the corneal material properties and topography. These data were then used to facilitate the construction of accurate finite-element models that are able to reliably trace the performance of cornea upon exposure to disease, injury or elevated intra-ocular pressure. The models are being adapted to study the response to keratoconus (a disease causing loss of corneal tissue) and to tonometry procedures, which are used to measure the intra-ocular pressure. This paper introduces these efforts as examples of the application of structural engineering analysis tools and shows their potential in the field of corneal biomechanics.
引用
收藏
页码:3 / 15
页数:13
相关论文
共 27 条
[1]   BIOMECHANICAL PROPERTIES OF KERATOCONUS AND NORMAL CORNEAS [J].
ANDREASSEN, TT ;
SIMONSEN, AH ;
OXLUND, H .
EXPERIMENTAL EYE RESEARCH, 1980, 31 (04) :435-441
[2]  
BRON AJ, 1988, CORNEA, V7, P163
[3]   Constitutive laws for biomechanical modeling of refractive surgery [J].
Bryant, MR ;
McDonnell, PJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (04) :473-481
[4]  
Buzard K A, 1992, Refract Corneal Surg, V8, P127
[5]   Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach [J].
Doughty, MJ ;
Zaman, ML .
SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) :367-408
[6]  
EDMUND C, 1989, ACTA OPHTHALMOL, V67
[7]   Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings [J].
Feltgen, N ;
Leifert, D ;
Funk, J .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (01) :85-87
[8]  
Gibson J.E., 1980, THIN SHELLS COMPUTIN
[9]  
GOLDMANN H, 1957, Ophthalmologica, V134, P221
[10]  
Gordon MO, 2002, ARCH OPHTHALMOL-CHIC, V120, P714