Design of System for Rugged, Low-Noise Fiber-Optic Access to High-Temperature, High-Pressure Environments

被引:13
作者
Whitney, Jean M. [1 ]
Takami, Kuya [1 ]
Sanders, Scott T. [1 ]
Okura, Yasuhiro
机构
[1] Univ Wisconsin, Engine Res Ctr, Madison, WI 53706 USA
关键词
Absorption spectroscopy; modal noise analysis; optical fiber sensors; SPARK PLUG; FUEL CONCENTRATION; GAS TEMPERATURE; MODAL NOISE; LASER; THERMOMETRY; TOMOGRAPHY; ENGINES;
D O I
10.1109/JSEN.2011.2156780
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper details a new design for fiber-optic access to harsh environments, with a particular focus on absorption spectroscopy in high-temperature, high-pressure combustion systems. A key component is a fiber-fused rod lens assembly which tolerates temperatures above 1100 degrees C and enables simple optical access without interferences from etalons or ambient absorbers. The fibers, rod lenses, and supporting ports are designed to provide line-of-sight optical access without the need for adjustable optomechanics. Fiber modal noise was minimized by actively aligning a photodiode to the multimode fiber's output facet, resulting in a shot-noise-limited SNR of 53 000 for the system.
引用
收藏
页码:3295 / 3302
页数:8
相关论文
共 33 条
[1]   Measurement of vibrations caused by railroad with fiber optic sensors [J].
Barreda, A. ;
Molina, T. ;
Valero, E. ;
Recuero, S. .
OPTICAL SENSING AND DETECTION, 2010, 7726
[2]   Estimation of signal noise induced by multimode optical fibers [J].
Bartula, Renata J. ;
Sanders, Scott T. .
OPTICAL ENGINEERING, 2008, 47 (03)
[3]   Application of time-division-multiplexed lasers for measurements of gas temperature and CH4 and H2O concentrations at 30 kHz in a high-pressure combustor [J].
Caswell, Andrew W. ;
Kraetschmer, Thilo ;
Rein, Keith ;
Sanders, Scott T. ;
Roy, Sukesh ;
Shouse, Dale T. ;
Gord, James R. .
APPLIED OPTICS, 2010, 49 (26) :4963-4972
[4]   REMOTE ELEMENTAL ANALYSIS BY LASER-INDUCED BREAKDOWN SPECTROSCOPY USING A FIBEROPTIC CABLE [J].
CREMERS, DA ;
BAREFIELD, JE ;
KOSKELO, AC .
APPLIED SPECTROSCOPY, 1995, 49 (06) :857-860
[5]  
Crossley S. D., 2006, P 18 INT C CANC
[6]   Magnetic resonance-coupled fluorescence tomography scanner for molecular imaging of tissue [J].
Davis, Scott C. ;
Pogue, Brian W. ;
Springett, Roger ;
Leussler, Christoph ;
Mazurkewitz, Peter ;
Tuttle, Stephen B. ;
Gibbs-Strauss, Summer L. ;
Jiang, Shudong S. ;
Dehghani, Hamid ;
Paulsen, Keith D. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (06)
[7]   Shot-noise-limited dual-beam detector for atmospheric trace-gas monitoring with near-infrared diode lasers [J].
Durry, G ;
Pouchet, I ;
Amarouche, N ;
Danguy, T ;
Megie, G .
APPLIED OPTICS, 2000, 39 (30) :5609-5619
[8]   Crank angle resolved determination of fuel-concentration and air/fuel ratio in a SI-production engine by using a modified optical spark plug [J].
Grosch, A. ;
Beushausen, V. ;
Thiele, O. .
ADVANCED MICROSYSTEMS FOR AUTOMOTIVE APPLICATIONS 2008, 2008, :105-+
[9]  
Hall MJ, 1996, TWENTY-SIXTH SYMPOSIUM (INTERNATIONAL) ON COMBUSTION, VOLS 1 AND 2, P2613
[10]   MODAL NOISE IN MULTIMODE FIBER LINKS - THEORY AND EXPERIMENT [J].
HILL, KO ;
TREMBLAY, Y ;
KAWASAKI, BS .
OPTICS LETTERS, 1980, 5 (06) :270-272