Odour sampling. 2. Comparison of physical and aerodynamic characteristics of sampling devices: A review

被引:70
作者
Hudson, N. [1 ,2 ]
Ayoko, G. A. [1 ]
机构
[1] Queensland Univ Technol, Sch Phys & Chem Sci, Int Lab Air Qual & Hlth, Brisbane, Qld 4001, Australia
[2] Dept Primary Ind & Fisheries Queensland, Toowoomba, Qld 4350, Australia
关键词
odour; emission; wind tunnel; chamber;
D O I
10.1016/j.biortech.2007.03.043
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Sampling devices differing greatly in shape, size and operating condition have been used to collect air samples to determine rates of emission of volatile substances, including odour. However, physical chemistry principles, in particular the partitioning of volatile substances between two phases as explained by Henrys Law and the relationship between wind velocity and emission rate, suggests that different devices cannot be expected to provide equivalent emission rate estimates. Thus several problems are associated with the use of static and dynamic emission chambers, but the more turbulent devices such as wind tunnels do not appear to be subject to these problems. In general, the ability to relate emission rate estimates obtained from wind tunnel measurements to those derived from device-independent techniques supports the use of wind tunnels to determine emission rates that can be used as input data for dispersion models. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3993 / 4007
页数:15
相关论文
共 103 条
[1]   A dynamic two-dimensional system for measuring volatile organic compound volatilization and movement in soils [J].
Allaire, SE ;
Yates, SR ;
Ernst, FF ;
Gan, J .
JOURNAL OF ENVIRONMENTAL QUALITY, 2002, 31 (04) :1079-1087
[2]  
[Anonymous], CHEMOS GLOBAL CHANGE
[3]  
[Anonymous], REFERENCE MANUAL EST
[4]  
[Anonymous], EPA600389008
[5]  
BAEK BH, 2003, 3 INT C AIR POLL AGR
[6]  
BAEK BH, 2003, CIGR INTS GAS OD EM, P493
[7]   Examination of four methods for measuring soil respiration [J].
Bekku, Y ;
Koizumi, H ;
Oikawa, T ;
Iwaki, H .
APPLIED SOIL ECOLOGY, 1997, 5 (03) :247-254
[8]   THE DEVELOPMENT OF A SAMPLING SYSTEM FOR THE DETERMINATION OF ODOR EMISSION RATES FROM AREAL SURFACES .2. MATHEMATICAL-MODEL [J].
BLISS, PJ ;
JIANG, KY ;
SCHULZ, TJ .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1995, 45 (12) :989-994
[9]   Measurement of odour with focus on sampling techniques [J].
Bockreis, A ;
Steinberg, I .
WASTE MANAGEMENT, 2005, 25 (09) :859-863
[10]  
CAPAREDA SC, 2004, ASAE CSAE ANN INT M