Predicting knee replacement damage in a simulator machine using a computational model with a consistent wear factor

被引:48
作者
Zhao, Dong
Sakoda, Hideyuki
Sawyer, W. Gregory
Banks, Scott A. [1 ]
Fregly, Benjamin J. [1 ]
机构
[1] Univ Florida, Dept Mech & Aerosp Engn, Dept Biomed Engn, Dept Orthopaed & Rehabil, Gainesville, FL 32611 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2008年 / 130卷 / 01期
关键词
dynamic contact simulation; computational wear prediction; knee simulator machine; total knee replacement; biomechanics;
D O I
10.1115/1.2838030
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Wear of ultrahigh molecular weight polyethylene remains a primary factor limiting the longevity of total knee replacements (TKRs). However wear testing on a simulator machine is time consuming and expensive, making it impractical for iterative design purposes. The objectives of this paper were first, to evaluate whether a computational model using a wear factor consistent with the TKR material pair can predict accurate TKR damage measured in a simulator machine, and second, to investigate how choice of surface evolution method (fixed or variable step) and material model (linear or nonlinear)affect the prediction. An iterative computational damage model was constructed for a commercial knee implant in an AMTI simulator machine. The damage model combined a dynamic contact model with a surface evolution model to predict how wear plus creep progressively alter tibial insert geometry over multiple simulations. The computational frame work was validated by predicting wear in a cylinder-on-plate system for which an analytical solution was derived. The implant damage model was evaluated for 5 million cycles of simulated gait using damage measurements made on the same implant in an AMTI machine. Using a pin-on-plate wear factor for the same material pair as the implant, the model predicted tibial insert wear volume to within 2% error and damage depths and areas to within 18% and 10% error respectively. Choice of material model had little influence, while inclusion of surface evolution affected damage depth and area but not wear volume predictions. Surface evolution method was important only during the initial cycles, where variable step was needed to capture rapid geometry changes due to the creep. Overall, our results indicate that accurate TKR damage predictions can be made with a computational model using a constant wear factor obtained from pin-on-plate tests for the same material pair and furthermore, that surface evolution method matters only during the initial "break in" period of the simulation.
引用
收藏
页数:10
相关论文
共 31 条
[21]  
2-G
[22]   Reduction in the initial wear of ultrahigh molecular weight polyethylene after compressive creep deformation [J].
Lee, KY ;
Pienkowski, D .
WEAR, 1997, 203 :375-379
[23]   Comparative wear under four different tribological conditions of acetylene enhanced cross-linked ultra high molecular weight polyethylene [J].
Marrs, H ;
Barton, DC ;
Jones, RA ;
Ward, IM ;
Fisher, J ;
Doyle, C .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1999, 10 (06) :333-342
[24]   Metrology to quantify wear and creep of polyethylene tibial knee inserts [J].
Muratoglu, OK ;
Perinchief, RS ;
Bragdon, CR ;
O'Connor, DO ;
Konrad, R ;
Harris, WH .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :155-164
[25]   Sagittal profile of the femoral condyles and its application to femorotibial contact analysis [J].
Nuño, M ;
Ahmed, AM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (01) :18-26
[26]   Retrieval, experimental, and computational assessment of the performance of total knee replacements [J].
Rawlinson, JJ ;
Furman, BD ;
Li, S ;
Wright, TM ;
Bartel, DL .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (07) :1384-1394
[27]  
Saikko V, 2000, J BIOMED MATER RES, V49, P147, DOI 10.1002/(SICI)1097-4636(200002)49:2<147::AID-JBM1>3.3.CO
[28]  
2-8
[29]   Why are total knee arthroplasties failing today? [J].
Sharkey, PF ;
Hozack, WJ ;
Rothman, RH ;
Shastri, S ;
Jacoby, SM .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) :7-13
[30]   A knee simulating machine for performance evaluation of total knee replacements [J].
Walker, PS ;
Blunn, GW ;
Broome, DR ;
Perry, J ;
Watkins, A ;
Sathasivam, S ;
Dewar, ME ;
Paul, JP .
JOURNAL OF BIOMECHANICS, 1997, 30 (01) :83-89