Thermal analysis of a double layer phase change material floor

被引:178
作者
Jin, Xing [1 ]
Zhang, Xiaosong [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China
关键词
Phase change material; Radiant floor system; Heating/cooling; Energy storage; Numerical simulation; ELECTRIC-HEATING SYSTEM; STABILIZED PCM PLATES; COOLING SYSTEM; BUILDINGS; STORAGE; PERFORMANCE; SIMULATION;
D O I
10.1016/j.applthermaleng.2011.01.023
中图分类号
O414.1 [热力学];
学科分类号
摘要
Phase change materials (PCMs) can be used to shift the cooling or heating load from the peak period to the off-peak period. In this paper, a new double layer phase change material (PCM) floor is put forward. The two layers of PCM have different melting temperature. The system is used to store heat or cold energy in the off-peak period and release them in the peak period during heating or cooling. According to the numerical model built in this paper, the thermal performances of the floor are analyzed. The results show that the optimal melting temperatures of PCMs exist. The fluctuations of the floor surface temperatures and the heat fluxes will be reduced and the system still can provide a certain amount of heat or cold energy after the heat pump or chiller has been turned off for a long time. Compared to the floor without PCM, the energy released by the floor with PCM in peak period, will be increased by 41.1% and 37.9% during heating and cooling when the heat of fusion of PCM is 150 kJ/kg. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1576 / 1581
页数:6
相关论文
共 16 条
[1]  
ATHIENITIS AK, 1993, ASHRAE TRAN, V99, P1049
[2]   Natural convection from heated room surfaces [J].
Awbi, HB ;
Hatton, A .
ENERGY AND BUILDINGS, 1999, 30 (03) :233-244
[3]   Experimental study of using PCM in brick constructive solutions for passive cooling [J].
Castell, A. ;
Martorell, I. ;
Medrano, M. ;
Perez, G. ;
Cabeza, L. F. .
ENERGY AND BUILDINGS, 2010, 42 (04) :534-540
[4]  
Dai Guosheng, 1999, HEAT TRANSFER
[5]   Underfloor heating with latent heat storage [J].
Farid, M ;
Kong, WJ .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2001, 215 (A5) :601-609
[6]   Domestic electrical space heating with heat storage [J].
Farid, MM ;
Chen, XD .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 1999, 213 (A2) :83-92
[7]   Modeling of phase change material peak load shifting [J].
Halford, C. K. ;
Boehm, R. F. .
ENERGY AND BUILDINGS, 2007, 39 (03) :298-305
[8]   Numerical simulation of radiant floor cooling system: The effects of thermal resistance of pipe and water velocity on the performance [J].
Jin, Xing ;
Zhang, Xiaosong ;
Luo, Yajun ;
Cao, Rongquan .
BUILDING AND ENVIRONMENT, 2010, 45 (11) :2545-2552
[9]   A calculation method for the floor surface temperature in radiant floor system [J].
Jin, Xing ;
Zhang, Xiaosong ;
Luo, Yajun .
ENERGY AND BUILDINGS, 2010, 42 (10) :1753-1758
[10]   Application of the control methods for radiant floor cooling system in residential buildings [J].
Department of Architecture, College of Engineering, Seoul National University, Seoul, Korea, Republic of ;
不详 ;
不详 .
Build. Environ., 2006, 1 (60-73) :60-73