Dynamic model and experimental validation of an indirect thermosyphon solar water heater coupled with a parallel circular tube rings type heat exchange coil

被引:10
作者
Tse, Ka-Kui [1 ]
Chow, Tin-Tai [1 ]
机构
[1] City Univ Hong Kong, Div Bldg Sci & Technol, Bldg Energy & Environm Technol Res Unit, Kowloon, Hong Kong, Peoples R China
关键词
Solar water heater; Thermosyphon flow; Heat exchanger; Dynamic model; THERMAL PERFORMANCE; LAMINAR-FLOW; SYSTEM; COLLECTOR; PIPES;
D O I
10.1016/j.solener.2015.01.032
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This article introduces the design of an indirect thermosyphon solar water heating system coupled with a parallel circular tube rings type heat exchanger. The proposed heat exchange coil set is able to provide similarly of heat exchange areas of a comparable size helical coil but reduces the friction loss of the thermosyphon fluid flow. The design can also maintain the thermal stratification along the vertical height of the storage water tank. Hence, the thermal efficiency of the solar water heater is improved as compared with a same system but coupled with a comparable size helical coil and shell type storage water tank. Detailed mathematical model development from individual components to the integration of whole system are described. The transient system model is simulated by a self-developed FORTRAN program. The experimental and simulations results of the solar thermal system are fully presented in this paper. Comparison of both results shows good agreements and convinces the accuracy of the entire system models as well as the suitability of the computational method. The effectiveness of the proposed heat exchange coil set is evaluated by its NTU value which is computed by program simulation. The NTU value reveals that the overall efficiency of the solar thermal system can be improved by further physical design optimization. Simulation results analyses also consolidate the enhancement of the thermosyphon flow rate (in other words, the efficiency) of the proposed design over the helical coil design as expected. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:114 / 133
页数:20
相关论文
共 31 条
  • [1] Pressure drop correlations for flow through regular helical coil tubes
    Ali, S
    [J]. FLUID DYNAMICS RESEARCH, 2001, 28 (04) : 295 - 310
  • [2] An experimental and numerical study of thermal stratification in a horizontal cylindrical solar storage tank
    Alizadeh, S
    [J]. SOLAR ENERGY, 1999, 66 (06) : 409 - 421
  • [3] [Anonymous], INT J HEAT FLUID FLO
  • [4] Bolaji B.O., 2006, J. Eng. Appl. Sci, V1, P7
  • [5] Cengel YA., 1998, HEAT TRANSFER PRACTI
  • [6] Computer modeling and experimental validation of a building-integrated photovoltaic and water heating system
    Chow, T. T.
    He, W.
    Chan, A. L. S.
    Fong, K. F.
    Lin, Z.
    Ji, J.
    [J]. APPLIED THERMAL ENGINEERING, 2008, 28 (11-12) : 1356 - 1364
  • [7] Performance evaluation of evacuated tube solar domestic hot water systems in Hong Kong
    Chow, Tin-Tai
    Dong, Zhaoting
    Chan, Lok-Shun
    Fong, Kwong-Fai
    Bai, Yu
    [J]. ENERGY AND BUILDINGS, 2011, 43 (12) : 3467 - 3474
  • [8] Hybrid photovoltaic-thermosyphon water heating system for residential application
    Chow, TT
    He, W
    Ji, J
    [J]. SOLAR ENERGY, 2006, 80 (03) : 298 - 306
  • [9] Numerical study of desirable solar-collector orientations for the coastal region of South China
    Chow, TT
    Chan, ALS
    [J]. APPLIED ENERGY, 2004, 79 (03) : 249 - 260
  • [10] Performance analysis of photovoltaic-thermal collector by explicit dynamic model
    Chow, TT
    [J]. SOLAR ENERGY, 2003, 75 (02) : 143 - 152