The Organic Peroxides Instability Rating Research Based on Adiabatic Calorimetric Approaches and Fuzzy Analytic Hierarchy Process for Inherent Safety Evaluation

被引:12
作者
Ni, Lei [1 ]
Jiang, Juncheng [1 ]
Wang, Zhirong [1 ]
Yao, Jun [1 ]
Song, Yuan [1 ]
Yu, Yuan [1 ]
机构
[1] Nanjing Tech Univ, Coll Safety Sci & Engn, Jiangsu Key Lab Hazardous Chem Safety & Control, Nanjing 210009, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
instability rating; Vent Sizing Package 2; accelerating rate calorimeter; organic peroxides; thermal hazard; fuzzy; analytic hierarchy process; HAZARD;
D O I
10.1002/prs.11754
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This article proposes a new method of instability classification of organic peroxides (ICOP) for assessing the risk of decomposition reaction of organic peroxides, based on the adiabatic calorimetric approaches and fuzzy analytic hierarchy process (FAHP). Tonset is set as instability possibility index. Maximal power density, adiabatic temperature rise, maximum pressure rate, and maximum pressure are set as instability severity index (ISI) with proper weightings by FAHP. Instability possibility index and ISI are converted into ICOP based on risk matrix. The organic peroxides instability can, therefore, be quantified and divided into four levels, acceptable, moderate risk, highly dangerous, and seriously dangerous. Thermal decomposition of di-tert-butyl peroxide 25 mass % and tert-butyl hydroperoxide 68.4 mass % are tested with Vent Sizing Package 2 and Phi-Tech 1 which has the function of Accelerating Rate Calorimeter, respectively. Thermal decompositions of other organic peroxides are presented from citation. The instability rating results of these organic peroxides are presented to illustrate the validity of the method. (C) 2015 American Institute of Chemical Engineers
引用
收藏
页码:200 / 207
页数:8
相关论文
共 20 条
[1]  
[Anonymous], 2013, PHI TEC OP MAN VER E
[2]  
[Anonymous], 2006, VSP2 US MAN TEST MET
[3]   Inclusion of pressure hazards into NFPA 704 instability rating system [J].
Carreto-Vazquez, V. H. ;
Hernandez, I. ;
Ng, D. ;
Rogers, W. J. ;
Mannan, M. S. .
JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2010, 23 (01) :30-38
[4]   Identifying criteria to classify chemical mixtures as "highly hazardous" due to chemical reactivity [J].
Crowl, DA ;
Elwell, TI .
JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2004, 17 (04) :279-289
[5]   Hazard ratings for organic peroxides [J].
Duh, Yih-Shing ;
wu, Xiao Hui ;
Kao, Chen-Shan .
PROCESS SAFETY PROGRESS, 2008, 27 (02) :89-99
[6]   A quantitative approach to determination of NFPA reactivity hazard rating parameters [J].
Hofelich, TC ;
Prine, BA ;
Scheffler, NE .
PROCESS SAFETY PROGRESS, 1997, 16 (03) :121-125
[7]   Calorimetric studies and lessons on fires and explosions of a chemical plant producing CHP and DCPO [J].
Hsu, Jing-Ming ;
Su, Mao-Sheng ;
Huang, Chiao-Ying ;
Duh, Yih-Shing .
JOURNAL OF HAZARDOUS MATERIALS, 2012, 217 :19-28
[8]   An index-based method for assessing exothermic runaway risk [J].
Kao, CS ;
Duh, YS ;
Chen, TJH ;
Yu, SW .
PROCESS SAFETY PROGRESS, 2002, 21 (04) :294-304
[9]   Medhodology and software for assessing reactivity ratings of chemical systems [J].
Kossoy, A ;
Hofelich, T .
PROCESS SAFETY PROGRESS, 2003, 22 (04) :235-240
[10]   Effects of thermal runaway hazard for three organic peroxides conducted by acids and alkalines with DSC, VSP2, and TAM III [J].
Liu, S. H. ;
Hou, H. Y. ;
Chen, J. W. ;
Weng, S. Y. ;
Lin, Y. C. ;
Shu, C. M. .
THERMOCHIMICA ACTA, 2013, 566 :226-232