Prognostic utility of T-wave alternans in a real-world population of patients with left ventricular dysfunction: the PREVENT-SCD study

被引:14
作者
Shizuta, Satoshi [1 ]
Ando, Kenji [2 ]
Nobuyoshi, Masakiyo [2 ]
Ikeda, Takanori [3 ]
Yoshino, Hideaki [3 ]
Hiramatsu, Shinichi [4 ]
Kazatani, Yukio [4 ]
Yamashiro, Kohei [5 ]
Okajima, Katsunori [5 ]
Kajiya, Teishi [5 ]
Kobayashi, Yoshinori [6 ]
Kato, Takao [6 ]
Fujii, Satoki [7 ]
Mitsudo, Kazuaki [7 ]
Inoue, Koichi [8 ]
Ito, Hiroshi [8 ]
Haruna, Yoshisumi [1 ]
Doi, Takahiro [1 ]
Nishio, Yukiko [1 ]
Ozasa, Neiko [1 ]
Nishiyama, Kei [1 ]
Kita, Toru [1 ]
Morimoto, Takeshi [9 ]
Kimura, Takeshi [1 ]
机构
[1] Kyoto Univ, Dept Cardiovasc Med, Grad Sch Med, Sakyo Ku, Kyoto 6068507, Japan
[2] Kokura Mem Hosp, Kitakyushu, Fukuoka, Japan
[3] Kyorin Univ, Sch Med, Mitaka, Tokyo 181, Japan
[4] Ehime Prefectural Cent Hosp, Matsuyama, Ehime, Japan
[5] Himeji Cardiovasc Ctr, Himeji, Hyogo, Japan
[6] Nippon Med Sch, Tokyo 113, Japan
[7] Kurashiki Cent Hosp, Kurashiki, Okayama, Japan
[8] Sakurabashi Watanabe Hosp, Osaka, Japan
[9] Kyoto Univ, Grad Sch Med, Ctr Med Educ, Kyoto 6068507, Japan
关键词
Sudden death; Ventricular arrhythmia; Cardiomyopathy; T-wave alternans; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; HEART-FAILURE; RISK STRATIFICATION; ARRHYTHMIAS; DEATH; CARDIOMYOPATHY; VULNERABILITY; INFARCTION; EJECTION; IMPACT;
D O I
10.1007/s00392-011-0368-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The predictive value of T-wave alternans (TWA) for lethal ventricular tachyarrhythmia in patients with left ventricular (LV) dysfunction is controversial. Also, long-term arrhythmia risk of patients ineligible for the TWA test is unknown. This was a multicenter, prospective observational study of patients with LV ejection fraction a parts per thousand currency sign40% due to ischemic or non-ischemic cardiomyopathies, designed to evaluate the prognostic value of TWA for lethal ventricular tachyarrhythmia. The primary end point was a composite of sudden cardiac death, sustained rapid ventricular tachycardia (VT) or ventricular fibrillation (VF), and appropriate defibrillator therapy for rapid VT or VF. Among 453 patients enrolled in the study, 280 (62%) were eligible for the TWA test. TWA was negative in 82 patients (29%), who accounted for 18% of the total population. The median of follow-up was 36 months. The 3-year event-free rate for the primary end point was significantly higher in TWA-negative patients (97.0%) than in TWA non-negative patients (89.5%, P = 0.037) and those ineligible for the TWA test (84.4%, P = 0.003). Multivariable analysis identified both non-negative TWA [hazard ratio (HR) 4.43; 95% confidence interval (CI) 1.02-19.2; P = 0.047) and ineligibility for the TWA test (HR 6.89; 95% CI 1.59-29.9; P = 0.010) to be independent predictors of the primary end point. TWA showed high negative predictive ability for lethal ventricular tachyarrhythmia in patients with LV dysfunction, although the TWA-negative patients accounted for only 18% of the entire population. Those ineligible for the TWA test had the highest risk for lethal ventricular tachyarrhythmia.
引用
收藏
页码:89 / 99
页数:11
相关论文
共 24 条
[1]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[2]   Microvolt T-wave alternans and the risk of death or sustained ventricular arrhythmias in patients with left ventricular dysfunction [J].
Bloomfield, DM ;
Bigger, JT ;
Steinman, RC ;
Namerow, PB ;
Parides, MK ;
Curtis, AB ;
Kaufman, ES ;
Davidenko, JM ;
Shinn, TS ;
Fontaine, JM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (02) :456-463
[3]   Interpretation and classification of microvolt T wave alternans tests [J].
Bloomfield, DM ;
Hohnloser, SH ;
Cohen, RJ .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (05) :502-512
[4]   Do Beta-Blockers Impact Microvolt T-Wave Alternans Testing in Patients at Risk for Ventricular Arrhythmias? A Meta-Analysis [J].
Chan, Paul S. ;
Gold, Michael R. ;
Nallamothu, Brahmajee K. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (09) :1009-1014
[5]   Prognostic utility of microvolt T-wave alternans in risk stratification of patients with ischemic cardiomyopathy [J].
Chow, T ;
Kereiakes, DJ ;
Bartone, C ;
Booth, T ;
Schloss, EJ ;
Waller, T ;
Chung, ES ;
Menon, S ;
Nallamothu, BK ;
Chan, PS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (09) :1820-1827
[6]   Does Microvolt T-Wave Alternans Testing Predict Ventricular Tachyarrhythmias in Patients With Ischemic Cardiomyopathy and Prophylactic Defibrillators? The MASTER (Microvolt T Wave Alternans Testing for Risk Stratification of Post-Myocardial Infarction Patients) Trial [J].
Chow, Theodore ;
Kereiakes, Dean J. ;
Onufer, John ;
Woelfel, Alan ;
Gursoy, Sinan ;
Peterson, Brett J. ;
Brown, Mark L. ;
Pu, Wenji ;
Benditt, David G. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (20) :1607-1615
[7]   The ABCD (Alternans Before Cardioverter Defibrillator) Trial [J].
Costantini, Otto ;
Hohnloser, Stefan H. ;
Kirk, Malcolm M. ;
Lerman, Bruce B. ;
Baker, James H., II ;
Sethuraman, Barathi ;
Dettmer, Mary M. ;
Rosenbaum, David S. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (06) :471-479
[8]   Role of Microvolt T-Wave Alternans in Assessment of Arrhythmia Vulnerability Among Patients With Heart Failure and Systolic Dysfunction Primary Results From the T-Wave Alternans Sudden Cardiac Death in Heart Failure Trial Substudy [J].
Gold, Michael R. ;
Ip, John H. ;
Costantini, Otto ;
Poole, Jeanne E. ;
McNulty, Steven ;
Mark, Daniel B. ;
Lee, Kerry L. ;
Bardy, Gust H. .
CIRCULATION, 2008, 118 (20) :2022-2028
[9]   Twiddler's syndrome in an adolescent patient with ICD during neurological and physical rehabilitation [J].
Herold, Joerg ;
Guenther, Michael ;
Strasser, Ruth H. ;
Braun, Martin .
CLINICAL RESEARCH IN CARDIOLOGY, 2009, 98 (02) :137-139
[10]   T-wave alternans negative coronary patients with low ejection and benefit from defibrillator implantation [J].
Hohnloser, SH ;
Ikeda, T ;
Bloomfield, DM ;
Dabbous, OH ;
Cohen, RJ .
LANCET, 2003, 362 (9378) :125-126