Biodegradable microfibrillar polymer-polymer composites from poly(L-lactic acid)/poly(glycolic acid)

被引:20
作者
Kimble, L. D. [1 ]
Bhattacharyya, D. [1 ]
Fakirov, S. [1 ]
机构
[1] Univ Auckland, Ctr Adv Composite Mat, Auckland 1, New Zealand
来源
EXPRESS POLYMER LETTERS | 2015年 / 9卷 / 03期
关键词
biocompatible polymers; biodegradable polymers; mechanical properties; microfibrillar polymer-polymer composites; viscoelasticity; REINFORCED COMPOSITES; MECHANICAL-PROPERTIES; STENT THROMBOSIS; CORONARY STENTS; BLENDS; RESTENOSIS; MORPHOLOGY;
D O I
10.3144/expresspolymlett.2015.27
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Biodegradable coronary stents have been under development for several years and a trend in biodegradable stent material development has emerged: reinforcement to enhance mechanical properties and creep resistance to improve vessel support. The aim of this work is to investigate the mechanical and viscoelastic characteristics of poly(L-lactic acid)/poly(glycolic acid) (PLLA/PGA) microfibrillar polymer-polymer composites (MFCs) at 37 degrees C to determine the suitability of PGA fibrils as a reinforcement for polymeric, biodegradable stents. PLLA/PGA MFCs were produced via cold-drawing and subsequent compression moulding of extruded PLLA/PGA blend wires. Scanning electron microscopy revealed excellent fibril formation in the case of a 70/30 wt% PLLA/PGA MFC- the mean fibril diameter being 400 nm and aspect ratios exceeding 250. Tensile tests demonstrate Young's modulus and strength increases of 35 and 84% over neat PLLA in the case of a 70/30 wt% PLLA/PGA MFC. Creep resistance of the PLLA/PGA MFCs is lower than that of neat PLLA, as shown via relaxation. Dynamic mechanical thermal analysis demonstrates that it is the onset of glass transition of PGA that is the underlying cause for low creep resistance of the PLLA/PGA MFCs at 37 degrees C.
引用
收藏
页码:300 / 307
页数:8
相关论文
共 28 条
  • [1] RELATIONSHIP BETWEEN CREEP AND STRESS RELAXATION
    AKLONIS, JJ
    TOBOLSKY, AV
    [J]. JOURNAL OF APPLIED PHYSICS, 1966, 37 (05) : 1949 - &
  • [2] EFFECT OF THE BLOCK LENGTH ON THE DEFORMATION-BEHAVIOR OF POLYETHERESTERS AS REVEALED BY SMALL-ANGLE X-RAY-SCATTERING
    APOSTOLOV, AA
    FAKIROV, S
    [J]. JOURNAL OF MACROMOLECULAR SCIENCE-PHYSICS, 1992, B31 (03): : 329 - 355
  • [3] Polyamide 6 single polymer composites
    Bhattacharyya, D.
    Maitrot, P.
    Fakirov, S.
    [J]. EXPRESS POLYMER LETTERS, 2009, 3 (08): : 525 - 532
  • [4] MICROFIBRILLAR REINFORCED COMPOSITE FROM DRAWN POLY(ETHYLENE-TEREPHTHALATE) NYLON-6 BLEND
    FAKIROV, S
    EVSTATIEV, M
    SCHULTZ, JM
    [J]. POLYMER, 1993, 34 (22) : 4669 - 4679
  • [5] MICROFIBRILLAR REINFORCED COMPOSITES - NEW MATERIALS FROM POLYMER BLENDS
    FAKIROV, S
    EVSTATIEV, M
    [J]. ADVANCED MATERIALS, 1994, 6 (05) : 395 - 398
  • [6] Nanofibril reinforced composites from polymer blends
    Fakirov, S.
    Bhattacharyya, D.
    Shields, R. J.
    [J]. COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2008, 313 (2-8) : 2 - 8
  • [7] Contribution of coalescence to microfibril formation in polymer blends during cold drawing
    Fakirov, S.
    Bhattacharyya, D.
    Lin, R. J. T.
    Fuchs, C.
    Friedrich, K.
    [J]. JOURNAL OF MACROMOLECULAR SCIENCE PART B-PHYSICS, 2007, 46 (01): : 183 - 193
  • [8] Microfibrillar reinforced composites from PET/LDPE blends: Morphology and mechanical properties
    Fakirov, S
    Kamo, H
    Evstatiev, M
    Friedrich, K
    [J]. JOURNAL OF MACROMOLECULAR SCIENCE-PHYSICS, 2004, B43 (04): : 775 - 789
  • [9] Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization
    Finn, Aloke V.
    Joner, Michael
    Nakazawa, Gaku
    Kolodgie, Frank
    Newell, John
    John, Mike C.
    Gold, Herman K.
    Virmani, Renu
    [J]. CIRCULATION, 2007, 115 (18) : 2435 - 2441
  • [10] Microfibrillar reinforced composites from PET/PP blends: processing, morphology and mechanical properties
    Friedrich, K
    Evstatiev, M
    Fakirov, S
    Evstatiev, O
    Ishii, M
    Harrass, M
    [J]. COMPOSITES SCIENCE AND TECHNOLOGY, 2005, 65 (01) : 107 - 116