Effects of Unilateral Tourniquet Used in Patients Undergoing Simultaneous Bilateral Total Knee Arthroplasty

被引:30
作者
Liu, Pei-lai [1 ]
Li, De-qiang [1 ]
Zhang, Yuan-kai [1 ]
Lu, Qun-shan [1 ]
Ma, Liang [1 ]
Bao, Xue-zhi [1 ]
Zhang, Meng [1 ]
机构
[1] Shandong Univ, Qilu Hosp, Dept Orthopaed, 107 Wenhua West Rd, Jinan 250012, Peoples R China
关键词
Deep vein thrombosis; Non-tourniquets; Total knee arthroplasty; Tourniquets; Wound complications; RELIABILITY; REPLACEMENT; SUBVASTUS; RECOVERY; STRENGTH; EXTENSOR; MOTION;
D O I
10.1111/os.12329
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To assess the benefits of use of a tourniquet in one limb in patients undergoing simultaneous bilateral total knee arthroplasty (TKA). Methods: A prospective randomized trial was designed to evaluate the outcomes of unilateral tourniquet use during simultaneous bilateral TKA. A total of 52 (36 women and 16 men) patients with osteoarthritis who underwent simultaneous bilateral primary TKA between January 2010 and January 2015 were assigned randomly to tourniquet (TG) or non-tourniquet (NG) groups prior to surgery. Operating time, pain score, range of motion, first active straight-leg raise time, swelling, wound healing, deep vein thrombosis, and Knee Society score were observed. Results: Mean operating time in the TG group was shorter than that in the NG group (P < 0.05). Postoperative pain was measured by a visual analog scale (VAS) and straight-leg raise time, which was lower and shorter in limbs operated without the use of a tourniquet (P < 0.05). In addition, this group had less postoperative swelling and lower incidence of wound complications in the early postoperative period (P < 0.05). There was no significant difference in the range of motion (ROM), deep venous thrombosis incidence, and Knee Society scores between the two groups. Conclusions: Tourniquet use in bilateral TKA can reduce intraoperative time but was associated with a higher incidence of wound complications and larger postoperative knee swelling.
引用
收藏
页码:180 / 185
页数:6
相关论文
共 27 条
[1]   EFFECTS OF TOURNIQUET DURING TOTAL KNEE ARTHROPLASTY - A PROSPECTIVE RANDOMIZED STUDY [J].
ABDELSALAM, A ;
EYRES, KS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (02) :250-253
[2]  
BERMAN AT, 1987, J BONE JOINT SURG AM, V69A, P1340
[3]   Reliability of the visual analog scale for measurement of acute pain [J].
Bijur, PE ;
Silver, W ;
Gallagher, EJ .
ACADEMIC EMERGENCY MEDICINE, 2001, 8 (12) :1153-1157
[4]   Intra- and intertester reliability and criterion validity of the parallelogram and universal goniometers for measuring maximum active knee flexion and extension of patients with knee restrictions [J].
Brosseau, L ;
Balmer, S ;
Tousignant, M ;
O'Sullivan, JP ;
Goudreault, C ;
Goudreault, M ;
Gringras, S .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2001, 82 (03) :396-402
[5]   Factors affecting wound ooze in total knee replacement [J].
Butt, U. ;
Ahmad, R. ;
Aspros, D. ;
Bannister, G. C. .
ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2011, 93 (01) :54-56
[6]  
Faure B T, 1993, J Arthroplasty, V8, P511
[7]  
Felicetti G, 2004, G Ital Med Lav Ergon, V26, P156
[8]   Effect of tourniquet application on deep vein thrombosis after total knee arthroplasty [J].
Fukuda, Aki ;
Hasegawa, Masahiro ;
Kato, Ko ;
Shi, Dequan ;
Sudo, Akihiro ;
Uchida, Atsumasa .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (08) :671-675
[9]   A randomized double-blind clinical trial of tourniquet application strategies for total knee arthroplasty [J].
Kvederas, Giedrius ;
Porvaneckas, Narunas ;
Andrijauskas, Audrius ;
Svensen, Christer H. ;
Ivaskevicius, Juozas ;
Mazunaitis, Justas ;
Marmaite, Ugne ;
Andrijauskas, Povilas .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (12) :2790-2799
[10]   Tourniquet use in total knee replacement does not improve fixation, but appears to reduce final range of motion A randomized RSA study involving 50 patients [J].
Ledin, Hakan ;
Aspenberg, Per ;
Good, Lars .
ACTA ORTHOPAEDICA, 2012, 83 (05) :499-503