Determination of calreticulin using Fe3O4@AuNPs core-shell functionalized with PT(COOH)2 polymer modified electrode: A new platform for the impedimetric biosensing of cancer biomarkers

被引:14
|
作者
Aydin, Elif Burcu [1 ]
Aydin, Muhammet [1 ]
Sezginturk, Mustafa Kemal [2 ]
机构
[1] Tekirdag Namik Kemal Univ, Sci & Technol Res Ctr, Tekirdag, Turkey
[2] Canakkale Onsekiz Mart Univ, Fac Engn, Bioengn Dept, Canakkale, Turkey
关键词
Calreticulin; Iron oxide nanoparticles; Fe3O4@AuNPs@PT(COOH)(2) core-shell; Impedimetric analysis; ELECTROCHEMICAL IMMUNOSENSOR; FE3O4; NANOPARTICLES; SERUM; RAMAN; TRANSITION;
D O I
10.1016/j.snb.2022.132099
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An innovative biosensing design strategy was utilized for the first time to develop a label-free and practical immunosensor for ultrasensitive analysis of calreticulin (CRT), a potential biomarker of breast carcinoma. Unlike strategies used in literature, a conjugated polymer carrying carboxyl groups on its backbone was synthesized and utilized as an immobilization matrix. This immunosensor design strategy was composed of the attachment of anti-CRT antibodies onto iron oxide nanoparticles@gold nanoparticles@poly(3-thiophenemalonic acid) polymer (Fe3O4@AuNPs@PT(COOH)(2)) functionalized indium tin oxide (ITO) electrode through carbodiimide coupling reaction. EIS measurement results illustrated significant changes in charge transfer resistance (R-ct) on immunoreaction between anti-CRT and CRT proteins. The proposed immunosensor enabled the detection of CRT over the range of 0.02 pg/mL and 100 pg/mL with a correlation coefficient of 0.9994 under optimal conditions. The detection limit (LOD), the quantification limit (LOQ) and the sensitivity were also determined to be 8.2 fg/mL, 27.4 fg/mL and 270 k Omega fg mL(-1)cm(2), respectively. Furthermore, it also exhibited good repeatability, excellent reproducibility, long storage stability and reusability. Experimental results analyzed with T-test to compare the means of the repeatability and reproducibility data, and F-test to the distribution of the repeatability and reproducibility data. According to T and F-tests, the experimental results achieved from the studies with the suggested immunosensor were relatively satisfactory. Furthermore, this immunosensor was tested to measure CRT levels in human serum and spiked human serum samples, and acceptable recovery rates ranging from 94.05% to 106.62% were obtained. In sum, considering its fast and easy-to-fabricate properties, this new strategy offers a potential tool for CRT biomarker detection.
引用
收藏
页数:13
相关论文
共 43 条
  • [1] Modified electrode by using magnetic core-shell Fe3O4@SiO2/MWCNT nanoparticles for determination of 6-mercaptopurine
    Abyar, Iman
    Asadollahzadeh, Hamideh
    Mohammadi, Sayed Zia
    Shahidi, Mehdi
    Ghazizadeh, Mahdieh
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2023, 34 (07)
  • [2] Electrochemical Determination of Gliclazide on Magnetic Core-Shell Fe3O4@SiO2 Functionalized Multiwall Carbon Nanotubes Modified Glassy Carbon Electrode
    Ganjali, Mohammad Reza
    Salimi, Hadiseh
    Tajik, Somayeh
    Beitollahi, Hadi
    Badiei, Alireza
    Ziarani, Ghodsi Mohammadi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (10): : 8868 - 8877
  • [3] Electrochemical determination of 6-Tioguanine by using modified screen-printed electrode: magnetic core-shell Fe3O4@SiO2/MWCNT nanoparticles
    Abyar, Iman
    Asadollahzadeh, Hamideh
    Mohammadi, Sayed Zia
    Shahidi, Mehdi
    Ghazizadeh, Mahdieh
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2023, 20 (06) : 1237 - 1245
  • [4] Simultaneous Voltammetric Determination of Synthetic Colorants in Foods Using a Magnetic Core-Shell Fe3O4@SiO2/MWCNTs Nanocomposite Modified Carbon Paste Electrode
    Arvand, Majid
    Parhizi, Yasaman
    Mirfathi, Seyed Hadi
    FOOD ANALYTICAL METHODS, 2016, 9 (04) : 863 - 875
  • [5] Electrocatalytic Determination of Hydrazine and Phenol Using a Carbon Paste Electrode Modified with Ionic Liquids and Magnetic Core-shell Fe3O4@SiO2/MWCNT Nanocomposite
    Beitollahi, Hadi
    Tajik, Somayeh
    Jahani, Shohreh
    ELECTROANALYSIS, 2016, 28 (05) : 1093 - 1099
  • [6] Modified electrode by using magnetic core–shell Fe3O4@SiO2/MWCNT nanoparticles for determination of 6-mercaptopurine
    Iman Abyar
    Hamideh Asadollahzadeh
    Sayed Zia Mohammadi
    Mehdi Shahidi
    Mahdieh Ghazizadeh
    Journal of Materials Science: Materials in Electronics, 2023, 34
  • [7] Voltammetric Investigation of Ketotifen Using Carbon Paste Electrode Modified by Magnetic Core-Shell Fe3O4@TMSPT Nanoparticles
    Mashhadizadeh, Mohammad Hossein
    Jeilanpour, Hanieh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2014, 6 (03): : 308 - 320
  • [8] A sensitive voltammetric sensor for methamphetamine determination based on modified glassy carbon electrode using Fe3O4@poly pyrrole core-shell and graphene oxide
    Riahifar, Vahid
    Haghnazari, Nahid
    Keshavarzi, Fatemeh
    Ahmadi, Elahe
    MICROCHEMICAL JOURNAL, 2021, 170
  • [9] An electrochemical sensing platform based on Fe3O4@CuO core-shell nanocomposite modified screen printed graphite electrode for sensitive hydroxylamine detection
    Mohammadi, Gholam Abbas
    Beitollahi, Hadi
    Sheikhshoaie, Iran
    Tajik, Somayeh
    Aflatoonian, Mohammad Reza
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2023, 103 (19) : 7773 - 7787
  • [10] A new sensing platform based on magnetic Fe3O4@NiO core/shell nanoparticles modified carbon paste electrode for simultaneous voltammetric determination of Quercetin and Tryptophan
    Tajyani, Sepideh
    Babaei, Ali
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 808 : 50 - 58