Experimental study of neutron induced background noise on gated x-ray framing cameras

被引:24
作者
Izumi, N. [1 ]
Hagmann, C. [1 ]
Stone, G. [1 ]
Hey, D. [1 ]
Glenn, S. [1 ]
Conder, A. [1 ]
Teruya, A. [1 ]
Sorce, C. [1 ]
Tommasini, R. [1 ]
Stoeffl, W. [1 ]
Springer, P. [1 ]
Landen, O. L. [1 ]
Herrmann, H. W. [2 ]
Kyrala, G. A. [2 ]
Bahukutumbi, R. [3 ]
Glebov, V. Y. [3 ]
Sangster, T. C. [3 ]
Eckart, M. [1 ]
Mackinnon, A. J. [1 ]
Koch, J. A. [1 ]
Bradley, D. K. [1 ]
Bell, P. [1 ]
机构
[1] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[2] Los Alamos Natl Lab, Los Alamos, NM 87544 USA
[3] Univ Rochester, Laser Energet Lab, Rochester, NY 14623 USA
关键词
D O I
10.1063/1.3478636
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A temporally gated x-ray framing camera based on a proximity focus microchannel plate is one of the most important diagnostic tools of inertial confinement fusion experiments. However, fusion neutrons produced in imploded capsules interact with structures surrounding the camera and produce background to x-ray signals. To understand the mechanisms of this neutron induced background, we tested several gated x-ray cameras in the presence of 14 MeV neutrons produced at the Omega laser facility. Differences between background levels observed with photographic film readout and charge-coupled-device readout have been studied. (C) 2010 American Institute of Physics. [doi: 10.1063/1.3478636]
引用
收藏
页数:3
相关论文
共 7 条
[1]   Characterization of x-ray framing cameras for use in inertial confinement fusion and radiation hydrodynamics experiments [J].
Bakeman, MS ;
Evans, SC ;
Oertel, JA ;
Walsh, PJ ;
Barnes, CW .
FOURTH-GENERATION X-RAY SOURCES AND ULTRAFAST X-RAY DETECTORS, 2004, 5194 :205-213
[2]   New constraints for plasma diagnostics development due to the harsh environment of MJ class lasers (invited) [J].
Bourgade, JL ;
Allouche, V ;
Baggio, J ;
Bayer, C ;
Bonneau, F ;
Chollet, C ;
Darbon, S ;
Disdier, L ;
Gontier, D ;
Houry, M ;
Jacquet, HP ;
Jadaud, JP ;
Leray, JL ;
Masclet-Gobin, I ;
Negre, JP ;
Raimbourg, J ;
Villette, B ;
Bertron, I ;
Chevalier, JM ;
Favier, JM ;
Gazave, J ;
Gomme, JC ;
Malaise, F ;
Seaux, JP ;
Glebov, VY ;
Jaanimagi, P ;
Stoeckl, C ;
Sangster, TC ;
Pien, G ;
Lerche, RA ;
Hodgson, ER .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10) :4204-4212
[3]   Modeling of neutron induced backgrounds in x-ray framing cameras [J].
Hagmann, C. ;
Izumi, N. ;
Bell, P. ;
Bradley, D. ;
Conder, A. ;
Eckart, M. ;
Khater, H. ;
Koch, J. ;
Moody, J. ;
Stone, G. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10)
[4]   Neutron-induced background in charge-coupled device detectors [J].
Jaanimagi, PA ;
Boni, R ;
Keck, RL .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01) :801-804
[5]   HIGH-SPEED PROXIMITY FOCUSED X-RAY CAMERAS [J].
KILKENNY, JD .
LASER AND PARTICLE BEAMS, 1991, 9 (01) :49-69
[6]   Neutron-induced noise in National Ignition Facility-class diagnostic instruments [J].
Lerche, RA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01) :628-631
[7]  
Tommasini R., COMMUNICATION