Application of the ICare Rebound Tonometer in Healthy Infants

被引:26
作者
Lundvall, Anna [1 ]
Svedberg, Helena [1 ]
Chen, Enping [1 ]
机构
[1] St Erik Eye Hosp, Karolinska Inst, S-11282 Stockholm, Sweden
关键词
IOP; ICare; rebound tonometer; GOLDMANN APPLANATION TONOMETER; MEASURING INTRAOCULAR-PRESSURE; CENTRAL CORNEAL THICKNESS; CLINICAL-EVALUATION; GLAUCOMA PATIENTS; CHILDREN;
D O I
10.1097/IJG.0b013e3181d1d1ef
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To study the tolerability of the ICare rebound tonometer (RBT) and to establish reference values of the intraocular pressure (IOP) in healthy infants. Participants and Methods: Forty-six children were recruited. In 6 infants aged 3 to 18 months, it was not possible to conduct the examination. Five children refused all cooperation. In 1 child, only 1 reading was obtained. In 1, partly uncooperative infant, the difference between the highest and the lowest reading exceeded 3 mm Hg (a difference of 7 mm Hg). These 7 infants were excluded. Totally 39 children, 22 girls and 17 boys, aged 1 month to 36 months were included in the study. The mean age was 14 +/- 9 months [mean +/- standard deviation (SD)]. One randomly selected eye of each child was examined with the ICare RBT. Three consecutive readings were made. In 10 children, IOP measurements were conducted twice with an interval of 10 to 30 minutes by 2 different ophthalmologists. Results: The mean IOP value of the 39 infants was 11.82 +/- 2.67 mm Hg. The median value was 10 mm Hg with a range of 7.3 to 17.0 mm Hg. In 10 children, the IOP was determined by 2 examiners. The results were virtually identical with differences of 0 to 1 mm Hg in 9 out of 10 children. The mean difference between Examiner 1 and Examiner 2 (0.77 mm Hg) was not statistically significant (P> 0.20). The examinations were very well tolerated, and no child showed any sign of discomfort during or after the examination. Conclusions: The hand-held RBT in the present study is easy to use, it does not require topical anesthesia and it is very well tolerated by cooperative infants. However, 7 out of 46 infants refused cooperation.
引用
收藏
页码:7 / 9
页数:3
相关论文
共 23 条
[1]   Comparison of the ICare® rebound tonometer with the Goldmann applanation tonometer by experienced and inexperienced tonometrists [J].
Abraham, L. M. ;
Epasinghe, N. C. R. ;
Selva, D. ;
Casson, R. .
EYE, 2008, 22 (04) :503-506
[2]   Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients [J].
Brusini, P ;
Salvetat, ML ;
Zeppieri, M ;
Tosoni, C ;
Parisi, L .
JOURNAL OF GLAUCOMA, 2006, 15 (03) :213-217
[3]   Clinical evaluation of rebound tonometer [J].
Davies, LN ;
Bartlett, H ;
Mallen, EAH ;
Wolffsohn, JS .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (02) :206-209
[4]   ANESTHESIA AND INTRAOCULAR-PRESSURE IN YOUNG-CHILDREN - A STUDY OF 3 DIFFERENT TECHNIQUES OF ANESTHESIA [J].
DEAR, GD ;
HAMMERTON, M ;
HATCH, DJ ;
TAYLOR, D .
ANAESTHESIA, 1987, 42 (03) :259-265
[5]   DYNAMIC TONOMETRY [J].
DEKKING, HM ;
COSTER, HD .
OPHTHALMOLOGICA, 1967, 154 (01) :59-&
[6]   Clinical evaluation of the dynamic rebound tonometer Icare® [J].
Detry-Morel, M. ;
Jamart, J. ;
Detry, M. B. ;
Pourjavan, S. ;
Charlier, L. ;
Dethinne, B. ;
Huge, L. ;
Ledoux, A. .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 2006, 29 (10) :1119-1127
[7]   Comparison of the ICare® rebound tonometer with the Goldmann tonometer in a normal population [J].
Fernandes, P ;
Díaz-Rey, JA ;
Queirós, A ;
Gonzalez-Meijome, JM ;
Jorge, J .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2005, 25 (05) :436-440
[8]   Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes [J].
García-Resúa, C ;
González-Meijome, JM ;
Gilino, J ;
Yebra-Pimentel, E .
OPTOMETRY AND VISION SCIENCE, 2006, 83 (02) :102-107
[9]   Pascal, ICare and Goldmann applanation tonometry -: a comparative study [J].
Johannesson, Gauti ;
Hallberg, Per ;
Eklund, Anders ;
Linden, Christina .
ACTA OPHTHALMOLOGICA, 2008, 86 (06) :614-621
[10]   A new electromechanical method for measuring intraocular pressure [J].
Kontiola, A .
DOCUMENTA OPHTHALMOLOGICA, 1997, 93 (03) :265-276