Residual Deformity After Treatment of Pediatric Femur Fractures With Flexible Titanium Nails

被引:35
|
作者
Sagan, Michelle L. [1 ]
Datta, Jason C. [2 ]
Olney, Brad W. [3 ]
Lansford, Todd J. [1 ]
McIff, Terence E. [1 ]
机构
[1] Univ Kansas, Med Ctr, Dept Orthoped Surg, Kansas City, KS 66160 USA
[2] UMKC Sch Med, Kansas City, MO USA
[3] Childrens Mercy Hosp, Kansas City, MO 64108 USA
关键词
pediatric femur fracture; flexible titanium nail; titanium elastic nail; deformity; ELASTIC NAILS; INTRAMEDULLARY NAILS; FEMORAL FRACTURES; FIXATION; COMPLICATIONS;
D O I
10.1097/BPO.0b013e3181efb8e2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Procurvatum or anterior bow deformity is a potential complication after treatment of femur fractures with flexible titanium nails (FTNs). This article reports on a clinical evaluation of angulation after treating pediatric femur fractures with FTNs. The article also reports on a complementary investigation of potential causes of these deformities using a biomechanical model. Methods: All pediatric femoral shaft fractures treated with FTNs over a 4-year period were reviewed. Fracture location, pattern, angulation, and nail shoe tip orientation were recorded from postoperative radiographs. Malunion was defined as greater than 10 degrees of angulation on the AP radiograph or greater than 15 degrees on the lateral view. As an adjunct to the clinical study, a synthetic femur model was created using midtransverse fractures. These femurs were nailed using 2 FTNs inserted so as to create constructs having the following combinations of nail shoe tip orientation: both anterior (AA), both posterior (PP), both neutral (NN), or 1 anterior and 1 posterior(AP). The resulting angular deformities noticeable upon gross inspection were then measured. Results: Of the 70 fractures reviewed, malunion occurred in 16 fractures, of which 11 had increased anterior bow. A majority of malunions was observed in older children with middle third of the femur fractures. They were significantly more prevalent in transverse fractures compared with all other fracture patterns. Clinically, increased anterior bowing did not occur if 1 of the nails was positioned to resist procurvatum, as seen in the lateral radiograph. Depending on nail tip orientation, the biomechanical femur fracture model showed significant differences in mean deformations after nail placement: AA had 12.6 degrees of posterior bow compared with 14.8, 3.7, and 0.3 degrees of anterior bow for PP, NN, and AP, respectively. Conclusion: Anterior bowing greater than 15 degrees is the most common malunion noted in this series of femur fractures that were nailed using FTN's. We conclude that final nail shoe tip orientation influences the likelihood of anterior bow deformity. The likelihood of large anterior bowing may be reduced if at least 1 of the nails is inserted with the tip pointing in an anterior direction. Level of Evidence/Clinical Relevance: Level III.
引用
收藏
页码:638 / 643
页数:6
相关论文
共 50 条
  • [21] Pediatric femur fractures, epidemiology and treatment
    Petkovic, Lazar
    Djan, Igor
    Gajdobranski, Djordje
    Maric, Dusan
    Petkovic, Mirjana
    VOJNOSANITETSKI PREGLED, 2011, 68 (01) : 9 - 14
  • [22] Comparison of SIGN Pediatric and Fin Nails in Pediatric Diaphyseal Femur Fractures: Early Clinical Results
    Shahabuddin
    Shahab, Faseeh
    Zirkle, Lewis G.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (02) : E46 - E50
  • [23] Elastic Stable Titanium Flexible Intramedullary Nails Versus Plates in Treating Low Grade Comminuted Femur Shaft Fractures in Children
    Luo, Yi
    Wang, Lin
    Zhao, Li-hua
    Wang, Yi-cheng
    Chen, Meng-jie
    Wang, Sun
    Ma, Qi-chao
    ORTHOPAEDIC SURGERY, 2019, 11 (04) : 664 - 670
  • [24] Rate of Refracture After Removal of Hardware in Pediatric Femur Fractures
    Siu, Jeremy W.
    Chan, Chloe
    Swarup, Ishaan
    Sabatini, Coleen S.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2023, 43 (08) : E674 - E679
  • [25] Titanium Elastic Nailing of Pediatric Femur Fractures
    Spiegel, David A.
    Ganley, Theodore J.
    Flynn, John M.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2005, 15 (04) : 326 - 330
  • [26] Comparing the Outcomes of Titanium and Stainless Steel Flexible Nails in Repairing Pediatric Long Bone Fractures
    Zamzam, Mazen
    Bopari, Novelpreet
    Arapovic, Avianna
    Kamel-ElSayed, Suzan
    Saleh, Ehab S.
    ORTHOPEDIC REVIEWS, 2024, 16
  • [27] Complications and failures of titanium elastic nailing in pediatric femur fractures
    S. Saseendar
    J. Menon
    D. K. Patro
    European Journal of Orthopaedic Surgery & Traumatology, 2010, 20 : 635 - 644
  • [28] Pediatric Humerus Fractures: Indications and Technique for Flexible Titanium Intramedullary Nailing
    Gordon, J. Eric
    Garg, Sumeet
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2010, 30 : S73 - S76
  • [29] Biomechanical Assessment of Cannulated Nails for the Treatment of Proximal Femur Fractures
    Frydrysek, Karel
    Halo, Tomas
    Cepica, Daniel
    Machalla, Vojtech
    Simeckova, Katerina
    Skoupy, Ondrej
    Madeja, Roman
    Havlicek, Miroslav
    Dostalova, Kamila
    Trefil, Antonin
    Pleva, Leopold
    Murcinkova, Zuzana
    Krpec, Pavel
    Hlinka, Josef
    APPLIED SCIENCES-BASEL, 2022, 12 (15):
  • [30] KIRSCHNER WIRE VERSUS TITANIUM ELASTIC NAILS IN PEDIATRIC FEMORAL SHAFT FRACTURES
    Isik, Cengiz
    Kurtulmus, Tuhan
    Saglam, Necdet
    Saka, Gursel
    Akpinar, Fuat
    Sarman, Hakan
    ACTA ORTOPEDICA BRASILEIRA, 2015, 23 (05): : 255 - 258