Low symptomatic premature stent occlusion of multiple plastic stents for benign biliary strictures: comparing standard and prolonged stent change intervals

被引:52
作者
Lawrence, Christopher [1 ]
Romagnuolo, Joseph [1 ]
Payne, K. Mark [1 ]
Hawes, Robert H. [1 ]
Cotton, Peter B. [1 ]
机构
[1] Med Univ S Carolina, Charleston, SC 29425 USA
关键词
BILE-DUCT STRICTURES; PROSPECTIVE RANDOMIZED-TRIAL; TERM-FOLLOW-UP; CHRONIC-PANCREATITIS; POLYETHYLENE STENTS; ENDOSCOPIC MANAGEMENT; STENOSIS SECONDARY; METAL STENTS; ENDOPROSTHESES; COMPLICATIONS;
D O I
10.1016/j.gie.2010.05.029
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Benign biliary strictures are typically managed endoscopically whereby an increasing size or number of plastic stents is placed at ERCP. Stents are often changed every 3 to 4 months based on the known median patency of a single biliary stent, but patency data for multiple biliary stents are lacking. Objective: To assess the incidence of occlusion-free survival of multiple plastic biliary stents and the rate of premature occlusion if left in longer than 6 months. Design: Retrospective. Setting: Tertiary-care medical center (Charleston, SC). Patients: Consecutive patients who received multiple plastic stents for benign nonhilar biliary strictures from 1994 to 2008 were identified. Interventions: Exchange of multiple plastic biliary stents within 6 months (group 1) or 6 months or longer (group 2) after placement. Main Outcome Measurements: Symptomatic stent occlusion. Results: Seventy-nine patients with nonhilar extrahepatic benign biliary stricture underwent 125 ERCPs with multiple plastic biliary stents. Stents were scheduled for removal/exchange within 6 months in 52 patients (86 ERCPs) compared with after 6 months in 22 patients (26 ERCPs). The median interval between multiple stent placement and removal/exchange was 90 days for group 1 and 242 clays for group 2. Premature stent occlusion occurred in 4 of 52 (7.7%) patients in group 1 versus 1 of 22 (4.5%) in group 2, with significantly longer occlusion-free survival, in group 2 (log-rank P < .0001). Limitations: Retrospective study at a single tertiary referral center. Conclusion: Multiple plastic biliary stents for benign nonhilar strictures were associated with a low rate of premature symptomatic stent occlusion at more than 6 months and a longer occlusion-free survival. (Gastrointest Endosc 2010;72:558-63.)
引用
收藏
页码:558 / 563
页数:6
相关论文
共 34 条
  • [31] Mechanisms of biliary stent clogging: Confocal laser scanning and scanning electron microscopy
    van Berkel, AM
    van Marle, J
    Groen, AK
    Bruno, MJ
    [J]. ENDOSCOPY, 2005, 37 (08) : 729 - 734
  • [32] van Berkel AM, 2003, ENDOSCOPY, V35, P478
  • [33] A prospective randomized trial of Teflon versus polyethylene stents for distal malignant biliary obstruction
    van Berkel, AM
    Boland, C
    Redekop, WK
    Bergman, JJGHM
    Groen, AK
    Tytgat, GNJ
    Huibregtse, K
    [J]. ENDOSCOPY, 1998, 30 (08) : 681 - 686
  • [34] Anastomotic biliary strictures after liver transplantation: Causes and consequences.
    Verdonk, RC
    Buis, CI
    Porte, RJ
    van der Jagt, EJ
    Limburg, AJ
    van den Berg, AP
    Sloff, MJH
    Peeters, PMJG
    de Jong, KP
    Kleibeuker, JH
    Haagsma, EB
    [J]. LIVER TRANSPLANTATION, 2006, 12 (05) : C33 - C33