Low symptomatic premature stent occlusion of multiple plastic stents for benign biliary strictures: comparing standard and prolonged stent change intervals

被引:52
作者
Lawrence, Christopher [1 ]
Romagnuolo, Joseph [1 ]
Payne, K. Mark [1 ]
Hawes, Robert H. [1 ]
Cotton, Peter B. [1 ]
机构
[1] Med Univ S Carolina, Charleston, SC 29425 USA
关键词
BILE-DUCT STRICTURES; PROSPECTIVE RANDOMIZED-TRIAL; TERM-FOLLOW-UP; CHRONIC-PANCREATITIS; POLYETHYLENE STENTS; ENDOSCOPIC MANAGEMENT; STENOSIS SECONDARY; METAL STENTS; ENDOPROSTHESES; COMPLICATIONS;
D O I
10.1016/j.gie.2010.05.029
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Benign biliary strictures are typically managed endoscopically whereby an increasing size or number of plastic stents is placed at ERCP. Stents are often changed every 3 to 4 months based on the known median patency of a single biliary stent, but patency data for multiple biliary stents are lacking. Objective: To assess the incidence of occlusion-free survival of multiple plastic biliary stents and the rate of premature occlusion if left in longer than 6 months. Design: Retrospective. Setting: Tertiary-care medical center (Charleston, SC). Patients: Consecutive patients who received multiple plastic stents for benign nonhilar biliary strictures from 1994 to 2008 were identified. Interventions: Exchange of multiple plastic biliary stents within 6 months (group 1) or 6 months or longer (group 2) after placement. Main Outcome Measurements: Symptomatic stent occlusion. Results: Seventy-nine patients with nonhilar extrahepatic benign biliary stricture underwent 125 ERCPs with multiple plastic biliary stents. Stents were scheduled for removal/exchange within 6 months in 52 patients (86 ERCPs) compared with after 6 months in 22 patients (26 ERCPs). The median interval between multiple stent placement and removal/exchange was 90 days for group 1 and 242 clays for group 2. Premature stent occlusion occurred in 4 of 52 (7.7%) patients in group 1 versus 1 of 22 (4.5%) in group 2, with significantly longer occlusion-free survival, in group 2 (log-rank P < .0001). Limitations: Retrospective study at a single tertiary referral center. Conclusion: Multiple plastic biliary stents for benign nonhilar strictures were associated with a low rate of premature symptomatic stent occlusion at more than 6 months and a longer occlusion-free survival. (Gastrointest Endosc 2010;72:558-63.)
引用
收藏
页码:558 / 563
页数:6
相关论文
共 34 条
  • [1] [Anonymous], 2002, Cochrane Database Syst Rev, DOI DOI 10.1002/14651858.CD003043
  • [2] Antibiotic prophylaxis for GI endoscopy
    Banerjee, Subhas
    Shen, Bo
    Baron, Todd H.
    Nelson, Douglas B.
    Anderson, Michelle A.
    Cash, Brooks D.
    Dominitz, Jason A.
    Gan, S. Ian
    Harrison, M. Edwyn
    Ikenberry, Steven O.
    Jagannath, Sanjay B.
    Lichtenstein, David
    Fanelli, Robert D.
    Lee, Ken
    van Guilder, Trina
    Stewart, Leslie E.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2008, 67 (06) : 791 - 798
  • [3] Long-term follow-up after biliary stent placement for postoperative bile duct stenosis
    Bergman, JJGHM
    Burgemeister, L
    Bruno, MJ
    Rauws, EAJ
    Gouma, DJ
    Tytgat, GNJ
    Huibregtse, K
    [J]. GASTROINTESTINAL ENDOSCOPY, 2001, 54 (02) : 154 - 161
  • [4] The treatment of patients with symptomatic common bile duct stenosis secondary to chronic pancreatitis using partially covered metal stents:: A pilot study
    Cantù, P
    Hookey, LC
    Morales, A
    Le Moine, O
    Devière, J
    [J]. ENDOSCOPY, 2005, 37 (08) : 735 - 739
  • [5] Treatment of symptomatic distal common bile duct stenosis secondary to chronic pancreatitis: comparison of single vs. multiple simultaneous stents
    Catalano, MF
    Linder, JD
    George, S
    Alcocer, E
    Geenen, JE
    [J]. GASTROINTESTINAL ENDOSCOPY, 2004, 60 (06) : 945 - 952
  • [6] Costamagna G, 2001, GASTROINTEST ENDOSC, V54, P162, DOI 10.1067/mge.2001.116876
  • [7] RANDOMIZED TRIAL OF SELF-EXPANDING METAL STENTS VERSUS POLYETHYLENE STENTS FOR DISTAL MALIGNANT BILIARY OBSTRUCTION
    DAVIDS, PHP
    GROEN, AK
    RAUWS, EAJ
    TYTGAT, GNJ
    HUIBREGTSE, K
    [J]. LANCET, 1992, 340 (8834-5) : 1488 - 1492
  • [8] De Palma GD, 2003, HEPATO-GASTROENTEROL, V50, P1229
  • [9] CLOGGING OF BILIARY ENDOPROSTHESES - A MORPHOLOGICAL AND BACTERIOLOGICAL STUDY
    DOWIDAR, N
    KOLMOS, HJ
    LYON, H
    MATZEN, P
    [J]. SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1991, 26 (11) : 1137 - 1144
  • [10] CLOGGING AND OTHER COMPLICATIONS OF ENDOSCOPIC BILIARY ENDOPROSTHESES
    DOWIDAR, N
    MOESGAARD, F
    MATZEN, P
    [J]. SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1991, 26 (11) : 1132 - 1136