摘要
The ability to assess an area of interest in 3 dimensions might benefit both novice and experienced clinicians alike. High-resolution limited cone-beam volumetric tomography (CBVT) has been designed for dental applications. As opposed to sliced-image data of conventional computed tomography (CT) imaging, CBVT captures a cylindrical volume of data in one acquisition and thus offers distinct advantages over conventional medical CT. These advantages include increased accuracy, higher resolution, scan-time reduction, and dose reduction. Specific endodontic applications of CBVT are being identified as the technology becomes more prevalent. CBVT has great potential to become a valuable tool in the modern endodontic practice. The objectives of this article are to briefly review cone-beam technology and its advantages over medical CT and conventional radiography, to illustrate current and future clinical applications of cone-beam technology in endodontic practice, and to discuss medicolegal considerations pertaining to the acquisition and interpretation of 3-dimensional data.
引用
收藏
页码:1121 / 1132
页数:12
相关论文
共 78 条
[1]   Accuracy of proximal caries depth measurements:: Comparison between limited cone beam computed tomography, storage phosphor and film radiography [J].
Akdeniz, B. Guniz ;
Grondahl, Hans-Goran ;
Magnusson, Bengt .
CARIES RESEARCH, 2006, 40 (03) :202-207
[2]  
Arnheiter C, 2006, Oral Radiology, V22, P80, DOI DOI 10.1007/S11282-006-0055-6
[3]   Using a flat-panel detector in high resolution cone beam CT for dental imaging [J].
Baba, R ;
Ueda, K ;
Okabe, M .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (05) :285-290
[4]   Comparison of flat-panel detector and image-intensifier detector for cone-beam CT [J].
Baba, R ;
Konno, Y ;
Ueda, K ;
Ikeda, S .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (03) :153-158
[5]   FACTORS INFLUENCING THE RADIOGRAPHIC APPEARANCE OF BONY LESIONS [J].
BENDER, IB .
JOURNAL OF ENDODONTICS, 1982, 8 (04) :161-170
[6]   ROENTGENOGRAPHIC AND DIRECT OBSERVATION OF EXPERIMENTAL LESIONS IN BONE .2 [J].
BENDER, IB ;
SELTZER, S .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1961, 62 (06) :708-&
[7]   ROENTGENOGRAPHIC AND DIRECT OBSERVATION OF EXPERIMENTAL LESIONS IN BONE .1. [J].
BENDER, IB ;
SELTZER, S .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1961, 62 (02) :152-&
[8]   Implant failures associated with asymptomatic endodontically treated teeth [J].
Brisman, DL ;
Brisman, AS ;
Moses, MS .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2001, 132 (02) :191-195
[9]   The use of cone beam computed tomography as an aid in evaluating and treatment planning for mandibular cancer [J].
Closmann, James J. ;
Schmidt, Brian L. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 65 (04) :766-771
[10]   Clinical indications for digital imaging in dento-alveolar trauma. Part 1: traumatic injuries [J].
Cohenca, Nestor ;
Simon, James H. ;
Roges, Ramon ;
Morag, Yoav ;
Malfaz, Jose Maria .
DENTAL TRAUMATOLOGY, 2007, 23 (02) :95-104