Simple and Patlak models for myocardial blood flow measurements with nitrogen-13-ammonia and PET in humans

被引:0
作者
Kitsukawa, S
Yoshida, K
Mullani, N
Nakagawa, K
Shimada, K
Takami, A
Himi, T
Masuda, Y
机构
[1] Natl Inst Radiol Sci, Div Adv Technol Med Imaging, Sect Clin Res, Inage Ku, Chiba 263, Japan
[2] Chiba Univ, Dept Internal Med 3, Chiba, Japan
[3] Univ Texas, Sch Med, Dept Internal Med, Div Cardiol, Houston, TX 77025 USA
关键词
PET; myocardial blood flow; nitrogen-13-ammonia; Patlak model; Simple model;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Simple and Patlak models for estimating myocardial blood flow with N-13-ammonia have become attractive for clinical applications with PET because of their simplicity and ease of implementation. However, these models are sensitive to factors such as the data acquisition times and data integration times, which can cause errors in the estimation of myocardial blood flow, as demonstrated in this study. Limiting the application of these models to specific conditions can minimize the errors. Methods: Dynamic PET images of the uptake of N-13-ammonia in the heart were obtained in seven humans under rest and dipyridamole stress. Myocardial blood flow was estimated using the Simple and Patlak models for different data acquisition times and data integration times. Blood flow values were compared to flow values computed with the two-compartment model as a reference. Results: Blood flow values calculated with the Simple and Patlak models during the first 2 min of data acquisition were closely correlated to the two-compartment model values. Longer acquisition times resulted in significant underestimation of blood flow for the Simple model. Long integration times of greater than 60 sec also resulted in significant underestimation of blood flow for both models. Conclusion: The Simple and Patlak models produce estimates of myocardial blood flow that are well correlated with the two-compartment model estimated blood flows for the integration time of 60 sec from 60 to 120 sec postinjection, Because of the errors associated with longer data acquisition times and longer integration times, use of these models should be limited to a well-documented data acquisition paradigm.
引用
收藏
页码:1123 / 1128
页数:6
相关论文
共 29 条
  • [1] Bassingthwaighte JB, 1997, J NUCL MED, V38, P264
  • [2] BELLINA CR, 1990, J NUCL MED, V31, P1335
  • [3] NONINVASIVE QUANTITATION OF MYOCARDIAL BLOOD-FLOW IN HUMAN-SUBJECTS WITH OXYGEN-15-LABELED WATER AND POSITRON EMISSION TOMOGRAPHY
    BERGMANN, SR
    HERRERO, P
    MARKHAM, J
    WEINHEIMER, CJ
    WALSH, MN
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) : 639 - 652
  • [4] DIRECT COMPARISON OF [N-13] AMMONIA AND [O-15]WATER ESTIMATES OF PERFUSION WITH QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW BY MICROSPHERES
    BOL, A
    MELIN, JA
    VANOVERSCHELDE, JL
    BAUDHUIN, T
    VOGELAERS, D
    DEPAUW, M
    MICHEL, C
    LUXEN, A
    LABAR, D
    COGNEAU, M
    ROBERT, A
    HEYNDRICKX, GR
    WIJNS, W
    [J]. CIRCULATION, 1993, 87 (02) : 512 - 525
  • [5] METABOLISM OF N-13 LABELED AMMONIA IN DIFFERENT CONDITIONS IN DOGS, HUMAN VOLUNTEERS AND TRANSPLANT PATIENTS
    BORMANS, G
    MAES, A
    LANGENDRIES, W
    NUYTS, J
    VROLIX, M
    VANHAECKE, J
    SCHIEPERS, C
    DEROO, M
    MORTELMANS, L
    VERBRUGGEN, A
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1995, 22 (02): : 116 - 121
  • [6] CHOI Y, 1993, J NUCL MED, V34, P488
  • [7] CHOI Y, 1993, J NUCL MED, V34, P1832
  • [8] Endo M, 1987, Ann Nucl Med, V1, P1
  • [9] NONINVASIVE QUANTIFICATION OF REGIONAL MYOCARDIAL PERFUSION WITH RB-82 AND POSITRON EMISSION TOMOGRAPHY - EXPLORATION OF A MATHEMATICAL-MODEL
    HERRERO, P
    MARKHAM, J
    SHELTON, ME
    WEINHEIMER, CJ
    BERGMANN, SR
    [J]. CIRCULATION, 1990, 82 (04) : 1377 - 1386
  • [10] HERRERO P, 1988, J NUCL MED, V29, P241