A novel nitromethane biosensor based on biocompatible conductive redox graphene-chitosan/hemoglobin/graphene/room temperature ionic liquid matrix

被引:56
|
作者
Wang, Lu [1 ]
Zhang, Xiuhua [1 ]
Xiong, Huayu [1 ]
Wang, Shengfu [1 ]
机构
[1] Hubei Univ, Coll Chem & Chem Engn, Minist Educ Key Lab Synth & Applicat Organ Funct, Wuhan 430062, Peoples R China
基金
中国国家自然科学基金;
关键词
Hemoglobin; Graphene; Room temperature ionic liquid; Nitromethane; Electrocatalysis; DIRECT ELECTRON-TRANSFER; DIRECT ELECTROCHEMISTRY; HEME-PROTEINS; ELECTROCATALYSIS; HEMOGLOBIN; EXPLOSIVES; FILMS;
D O I
10.1016/j.bios.2010.08.027
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel amperometric biosensor for nitromethane (CH3NO2) based on immobilization of graphene (GR), chitosan (CS), hemoglobin (Hb) and room temperature ionic liquid (IL) on a glassy carbon electrode (GCE) was developed for the first time. The surface morphologies of a set of representative membranes were characterized by means of scanning electron microscopy (SEM). The electrochemical performance of the biosensor was evaluated by cyclic voltammetry (CV) and chronoamperometry. A pair of stable and well-defined redox peaks of Hb with a formal potential of -0.240 V was observed at the GR-CS/Hb/GR/IL/GCE. The effects of phosphate buffer pH, scan rate, and temperature on the biosensor were investigated to provide optimum analytical performance. Moreover, several electrochemical parameters, e.g., the heterogeneous electron transfer rate constant (k(s)), were calculated in detail. The presence of both GR and IL not only dramatically facilitated the electron transfer of Hb, but also greatly enhanced electrocatalytic activity towards CH3NO2. The apparent Michaelis-Menten constant was down to 0.16 mu M, indicating that the biosensor possessed high affinity to CH3NO2. Besides this, the proposed biosensor exhibited fast amperometric response (<5s), low detection limit (6.0 x 10(-10) M), and excellent long-time storage stability for the determination of CH3NO2. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:991 / 995
页数:5
相关论文
共 50 条
  • [41] A novel room temperature POSS ionic liquid-based solid polymer electrolyte
    Fu, Jifang
    Lu, Qi
    Shang, Dapeng
    Chen, Liya
    Jiang, Yong
    Xu, Yufeng
    Yin, Jintao
    Dong, Xing
    Deng, Wei
    Yuan, Shuai
    JOURNAL OF MATERIALS SCIENCE, 2018, 53 (11) : 8420 - 8435
  • [42] Catalyst-free growth of single- to few-layered graphene on ionic liquid surfaces at room temperature
    Shen, Jiawei
    Gao, Cheng
    Ye, Xuheng
    He, Yi
    Tao, Xiangming
    Yang, Bo
    Wang, Miao
    Ye, Gaoxiang
    CRYSTENGCOMM, 2021, 23 (23) : 4169 - 4174
  • [43] Graphene-Ionic Liquid Based Hybrid Nanomaterials as Novel Lubricant for Low Friction and Wear
    Khare, Varsha
    Minh-Quan Pham
    Kumari, Nitee
    Yoon, Hae-Sung
    Kim, Chung-Soo
    Park, Jae-Il
    Ahn, Sung-Hoon
    ACS APPLIED MATERIALS & INTERFACES, 2013, 5 (10) : 4063 - 4075
  • [44] High sensitive reduced graphene oxide-based room temperature ionic liquid electrochemical gas sensor with carbon-gold nanocomposites amplification
    Wan, Hao
    Gan, Ying
    Sun, Jiadi
    Liang, Tao
    Zhou, Shuqi
    Wang, Ping
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 299
  • [45] Green synthesis of monolithic column incorporated with graphene oxide using room temperature ionic liquid and eutectic solvents for capillary electrochromatography
    Li, Xin-Xin
    Zhang, Li-Shun
    Wang, Chao
    Huang, Yan-Ping
    Liu, Zhao-Sheng
    TALANTA, 2018, 178 : 763 - 771
  • [46] Direct electron transfer of cytochrome c and its biosensor based on gold nanoparticles/room temperature ionic liquid/carbon nanotubes composite film
    Xiang, Cuili
    Zou, Yongjin
    Sun, Li-Xian
    Xu, Fen
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (01) : 38 - 41
  • [47] Ionic Liquid Functionalized Graphene-Based Electrochemical Biosensor for Simultaneous Determination of Dopamine and Uric Acid in the Presence of Ascorbic Acid
    Wang, Chunfeng
    Xu, Panpan
    Zhuo, Kelei
    ELECTROANALYSIS, 2014, 26 (01) : 191 - 198
  • [48] A novel BOD biosensor based on entrapped activated sludge in a porous chitosan-albumin cryogel incorporated with graphene and methylene blue
    Niyomdecha, Saroh
    Limbut, Warakorn
    Numnuam, Apon
    Asawatreratanakul, Punnee
    Kanatharana, Proespichaya
    Thavarungkul, Panote
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 241 : 473 - 481
  • [49] Dye-sensitized solar cells based on cobalt-containing room temperature ionic liquid redox shuttles
    Wang, Zhenyong
    Wang, Lei
    Zhang, Ye
    Guo, Jiangna
    Li, Hao
    Yan, Feng
    RSC ADVANCES, 2017, 7 (23): : 13689 - 13695
  • [50] Gold Nanoparticle (Au NP)-Decorated Ionic Liquid (IL) Based Liposome: A Stable, Biocompatible, and Conductive Biomimetic Platform for the Fabrication of an Enzymatic Electrochemical Glucose Biosensor
    Chen, Hongzhuang
    Fan, Jialin
    Chen, Xue
    Ma, Zhenkuan
    Zhang, Ling
    Chen, Xuwei
    ANALYTICAL LETTERS, 2023, 56 (12) : 2021 - 2039