A tin filter?s dose reduction effect revisited: Using the detectability index in low-dose computed tomography for the chest

被引:6
|
作者
Hasegawa, Akira [1 ,2 ]
Ichikawa, Katsuhiro [3 ]
Morioka, Yusuke [2 ,4 ]
Kawashima, Hiroki [3 ]
机构
[1] Niigata Univ Hlth & Welf, Fac Med Technol, Dept Radiol Technol, 1398 Shimami cho,Kita ku, Niigata, Niigata 9503198, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[3] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Fac Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[4] Toyama Prefectural Cent Hosp, Dept Radiol, 2-2-78 Nishinagae, Toyama, Toyama 9308550, Japan
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2022年 / 99卷
关键词
Chest computed tomography; Tin filter; Radiation dose; Detectability index; IMAGE QUALITY; ITERATIVE RECONSTRUCTION; SPECTRAL FILTRATION; 100; KVP; CT; PERFORMANCE;
D O I
10.1016/j.ejmp.2022.05.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To reevaluate a tin filter's (TF) dose reduction effect in computed tomography (CT) using a combination of an anthropomorphic chest phantom and a rod-shaped phantom. Methods and materials: A third-generation dual-source CT system equipped with a built-in TF was employed. A chest phantom was scanned under low-dose conditions of 0.2 to 1.0 mGy with the TF at 100 kV (TF100kV) and without it at 100 kV and 120 kV (NF100kV and NF120kV). To eliminate effects other than that of the TF, only filtered back projection (FBP) was used for image reconstruction. On the images of the rod phantom placed inside the lung field, the CT number and the spatial resolution using the modulation transfer function (MTF) were measured. Using these indices plus the noise power spectrum (NPS) that was also measured, the detectability index based on the non-prewhitening model observer (d'NPW) was calculated.Results: The CT numbers and MTFs were almost identical across the three conditions. The area under the NPS curve was decreased by 13-17% with the TF compared with non-TF conditions. NPS increases at low frequencies of < 0.06 mm-1 observed in NF120kV and NF100kV were eliminated by TF100kV. The potential dose reduction by the TF, estimated using the d'NPW values, turned out to be 22 to 25%.Conclusion: Based on the analysis of the FBP images of a chest phantom, the dose reduction attributable only to the TF was estimated at 22-25%, notably lower than those reported in previous studies.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [41] Low-dose computed tomography image restoration using previous normal-dose scan
    Ma, Jianhua
    Huang, Jing
    Feng, Qianjin
    Zhang, Hua
    Lu, Hongbing
    Liang, Zhengrong
    Chen, Wufan
    MEDICAL PHYSICS, 2011, 38 (10) : 5713 - 5731
  • [42] Patient dose reduction for a localizer radiograph with an additional tin filter in chest-abdomen-pelvis, spine, and head computed tomography examinations
    Takemitsu, Masaki
    Takegami, Kazuki
    Kudomi, Shohei
    Kawanami, Kaito
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2023, 16 (02) : 160 - 167
  • [43] 75% radiation dose reduction using deep learning reconstruction on low-dose chest CT
    Jo, Gyeong Deok
    Ahn, Chulkyun
    Hong, Jung Hee
    Kim, Da Som
    Park, Jongsoo
    Kim, Hyungjin
    Kim, Jong Hyo
    Goo, Jin Mo
    Nam, Ju Gang
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [44] A sinogram denoising algorithm for low-dose computed tomography
    Karimi, Davood
    Deman, Pierre
    Ward, Rabab
    Ford, Nancy
    BMC MEDICAL IMAGING, 2016, 16
  • [45] Image Fusion for Low-Dose Computed Tomography Reconstruction
    Ma, Jianhua
    Huang, Jing
    Liang, Zhengrong
    Zhang, Hua
    Fan, Yi
    Feng, Qianjin
    Chen, Wufan
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4239 - 4243
  • [46] Screening for Lung Cancer With Low-Dose Computed Tomography
    Miller, Anthony B.
    ONCOLOGIST, 2013, 18 (08) : 897 - 899
  • [47] VARIATIONAL DEEP LEARNING FOR LOW-DOSE COMPUTED TOMOGRAPHY
    Kobler, Erich
    Muckley, Matthew
    Chen, Baiyu
    Knoll, Florian
    Hammernik, Kerstin
    Pock, Thomas
    Sodickson, Daniel
    Otazo, Ricardo
    2018 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2018, : 6687 - 6691
  • [48] Screening for Lung Cancer With Low-Dose Computed Tomography
    Brodersen, John
    Dirksen, Asger
    Pedersen, Jesper Holst
    ANNALS OF INTERNAL MEDICINE, 2014, 160 (03) : 211 - 212
  • [49] Added Value of Ultra-low-dose Computed Tomography, Dose Equivalent to Chest X-Ray Radiography, for Diagnosing Chest Pathology
    Kroft, Lucia J. M.
    van der Velden, Levinia
    Giron, Irene Hernandez
    Roelofs, Joost J. H.
    de Roos, Albert
    Geleijns, Jacob
    JOURNAL OF THORACIC IMAGING, 2019, 34 (03) : 179 - 186
  • [50] Lung Cancer Screening With Low-Dose Computed Tomography
    Reck, Martin
    Dettmer, Sabine
    Kauczor, Hans-Ulrich
    Kaaks, Rudolf
    Reinmuth, Niels
    Vogel-Claussen, Jens
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2023, 120 (23): : 387 - +