A tin filter?s dose reduction effect revisited: Using the detectability index in low-dose computed tomography for the chest

被引:6
|
作者
Hasegawa, Akira [1 ,2 ]
Ichikawa, Katsuhiro [3 ]
Morioka, Yusuke [2 ,4 ]
Kawashima, Hiroki [3 ]
机构
[1] Niigata Univ Hlth & Welf, Fac Med Technol, Dept Radiol Technol, 1398 Shimami cho,Kita ku, Niigata, Niigata 9503198, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[3] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Fac Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[4] Toyama Prefectural Cent Hosp, Dept Radiol, 2-2-78 Nishinagae, Toyama, Toyama 9308550, Japan
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2022年 / 99卷
关键词
Chest computed tomography; Tin filter; Radiation dose; Detectability index; IMAGE QUALITY; ITERATIVE RECONSTRUCTION; SPECTRAL FILTRATION; 100; KVP; CT; PERFORMANCE;
D O I
10.1016/j.ejmp.2022.05.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To reevaluate a tin filter's (TF) dose reduction effect in computed tomography (CT) using a combination of an anthropomorphic chest phantom and a rod-shaped phantom. Methods and materials: A third-generation dual-source CT system equipped with a built-in TF was employed. A chest phantom was scanned under low-dose conditions of 0.2 to 1.0 mGy with the TF at 100 kV (TF100kV) and without it at 100 kV and 120 kV (NF100kV and NF120kV). To eliminate effects other than that of the TF, only filtered back projection (FBP) was used for image reconstruction. On the images of the rod phantom placed inside the lung field, the CT number and the spatial resolution using the modulation transfer function (MTF) were measured. Using these indices plus the noise power spectrum (NPS) that was also measured, the detectability index based on the non-prewhitening model observer (d'NPW) was calculated.Results: The CT numbers and MTFs were almost identical across the three conditions. The area under the NPS curve was decreased by 13-17% with the TF compared with non-TF conditions. NPS increases at low frequencies of < 0.06 mm-1 observed in NF120kV and NF100kV were eliminated by TF100kV. The potential dose reduction by the TF, estimated using the d'NPW values, turned out to be 22 to 25%.Conclusion: Based on the analysis of the FBP images of a chest phantom, the dose reduction attributable only to the TF was estimated at 22-25%, notably lower than those reported in previous studies.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [31] Ultra-low dose chest computed tomography: Effect of iterative reconstruction levels on image quality
    Afadzi, Mercy
    Lysvik, Elisabeth Kirkeby
    Andersen, Hilde Kjernlie
    Martinsen, Anne Catrine T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 114 : 62 - 68
  • [32] Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients
    François Pontana
    Alain Duhamel
    Julien Pagniez
    Thomas Flohr
    Jean-Baptiste Faivre
    Anne-Lise Hachulla
    Jacques Remy
    Martine Remy-Jardin
    European Radiology, 2011, 21 : 636 - 643
  • [33] Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients
    Pontana, Francois
    Duhamel, Alain
    Pagniez, Julien
    Flohr, Thomas
    Faivre, Jean-Baptiste
    Hachulla, Anne-Lise
    Remy, Jacques
    Remy-Jardin, Martine
    EUROPEAN RADIOLOGY, 2011, 21 (03) : 636 - 643
  • [34] Deep Learning Denoising of Low-Dose Computed Tomography Chest Images: A Quantitative and Qualitative Image Analysis
    Azour, Lea
    Hu, Yunan
    Ko, Jane P.
    Chen, Baiyu
    Knoll, Florian
    Alpert, Jeffrey B.
    Brusca-Augello, Geraldine
    Mason, Derek M.
    Wickstrom, Maj L.
    Kwon, Young Joon
    Babb, James
    Liang, Zhengrong
    Moore, William H.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (02) : 212 - 219
  • [35] The Use of Low-Dose Chest Computed Tomography for the Diagnosis and Monitoring of Pulmonary Infections in Patients with Hematologic Malignancies
    Agadakos, Efthimios
    Zormpala, Alexandra
    Zaios, Nikolaos
    Kapsiocha, Chrysoula
    Gamaletsou, Maria N.
    Voulgarelis, Michael
    Sipsas, Nikolaos V.
    Moulopoulos, Lia Angela
    Koutoulidis, Vassilis
    CANCERS, 2024, 16 (01)
  • [36] Low-dose computed tomography perceptual image quality assessment
    Lee, Wonkyeong
    Wagner, Fabian
    Galdran, Adrian
    Shi, Yongyi
    Xia, Wenjun
    Wang, Ge
    Mou, Xuanqin
    Ahamed, Md. Atik
    Imran, Abdullah Al Zubaer
    Oh, Ji Eun
    Kim, Kyungsang
    Baek, Jong Tak
    Lee, Dongheon
    Hong, Boohwi
    Tempelman, Philip
    Lyu, Donghang
    Kuiper, Adrian
    van Blokland, Lars
    Calisto, Maria Baldeon
    Hsieh, Scott
    Han, Minah
    Baek, Jongduk
    Maier, Andreas
    Wang, Adam
    Gold, Garry Evan
    Choi, Jang-Hwan
    MEDICAL IMAGE ANALYSIS, 2025, 99
  • [37] Low-dose multidetector computed tomography of the cervical spine: optimization of iterative reconstruction strength levels
    Omoumi, Patrick
    Verdun, Francis R.
    Ben Salah, Yosr
    Vande Berg, Bruno C.
    Lecouvet, Frederic E.
    Malghem, Jacques
    Ott, Julien G.
    Meuli, Reto
    Becce, Fabio
    ACTA RADIOLOGICA, 2014, 55 (03) : 335 - 344
  • [38] What future for chest x-ray against ultra-low-dose computed tomography?
    Ohana, M.
    Ludes, C.
    Schaal, M.
    Meyer, E.
    Jeung, M. -Y.
    Labani, A.
    Roy, C.
    REVUE DE PNEUMOLOGIE CLINIQUE, 2017, 73 (01) : 3 - 12
  • [39] Low-Dose Computed Tomography for the Optimization of Radiation Dose Exposure in Patients with Crohn's Disease
    Kavanagh, Richard G.
    O'Grady, John
    Carey, Brian W.
    McLaughlin, Patrick D.
    O'Neill, Siobhan B.
    Maher, Michael M.
    O'Connor, Owen J.
    GASTROENTEROLOGY RESEARCH AND PRACTICE, 2018, 2018
  • [40] Artifact reduction in low and ultra-low dose chest computed tomography for patients with pacemaker: A phantom study
    Watanabe, S.
    Urikura, A.
    Ohashi, K.
    Kitera, N.
    Tsuchiya, T.
    Kasai, H.
    Kawai, T.
    Hiwatashi, A.
    RADIOGRAPHY, 2024, 30 (03) : 770 - 775